Page 71

Calibration

Window of Interest (WOI) Framing Definition:

Serial Cmd: Default: Options:

Configured WOI

If a WOI framing mode is enabled, it will set the camera WOI to a full-size image when calibration begins. Once a symbol is decoded, the camera WOI will be zoomed-in both vertically and horizontally (regardless of which WOI mode is enabled) to include the symbol plus an additional margin area. This is done to accelerate the calibration process. When a successful calibration process is completed, the camera WOI will be adjusted according to the mode enabled. Otherwise, the original WOI configuration will be retained. <K529,gain,shutter speed,focus position,symbol type,WOI framing,WOI margin,line scan height,processing> Disabled 0 = Disabled 1 = Row and Column 2 = Row 3 = Column 4 = Straight Line 5 = Straight Line Framed

Starting WOI

After Decode

Calibration Passed

Calibration Failed

If WOI framing is not enabled, the current WOI configuration will be used until a symbol has been decoded. After a symbol is decoded, the WOI is framed exactly as it would be if a WOI framing mode was enabled. When the calibration process is complete, the original WOI configuration is restored. Refer to the diagram below:

Configured WOI

After Decode

Calibration Passed

MINI Hawk Xi High Performance Imager User Manual

Calibration Failed

4-7

Page 72

Calibration Options

Disabled When this feature is disabled, the Window of Interest is not modified after the calibration process is complete.

Row and Column If the calibration process is successful, the Window of Interest will be modified to frame the symbol as well as an additional margin area around the symbol, determined by the WOI Margin parameter. Refer to the diagram below:

Column If the calibration process is successful, the Window of Interest columns will be modified to vertically frame the symbol, plus an additional margin area around the symbol, determined by the WOI Margin parameter. Refer to the diagram below:

Row If the calibration process is successful, the Window of Interest rows will be modified to horizontally frame the symbol, plus an additional margin area around the symbol, determined by the WOI Margin parameter. Refer to the diagram below:

4-8

MINI Hawk Xi High Performance Imager User Manual

Page 73

Calibration

Straight Line This feature is intended for use with linear symbologies. If the calibration process is successful, the orientation of the symbol is determined and the Window of Interest is modified according to the symbol orientation. The scan line orientation is determined to be vertical if the symbol tilt is between 225° and 315°, or between 45° and 135°. Otherwise, the scan line will be horizontal. If the symbol is vertical, the image column size will be set by the scan height parameter, and will be configured for full row resolution. If the symbol is horizontal, the image row size will be set by the scan height parameter, and will be configured for full column resolution. The scan line will be centered in the middle of the symbol. If the symbol is tilted such that the scan line will not pass completely through the symbol, the scan width will be adjusted to include the entire symbol. Refer to the diagram below:

Straight Line Framed This parameter is the same as “Straight Line”, except that the Window of Interest will also frame the scan line on the symbol length as well. The scan line includes the symbol plus an additional margin area determined by the WOI Margin parameter.

MINI Hawk Xi High Performance Imager User Manual

4-9

Page 74

Calibration Options

Window of Interest (WOI) Margin Definition: Serial Cmd: Default: Options:

Sets the margin size that is applied to the calibrated symbol. This parameter is expressed in number of pixels. If the margin causes the image to exceed the maximum image size, it will be reduced accordingly. <K529,gain,shutter speed,focus position,symbol type,WOI framing,WOI margin,line scan height,processing> 75 (pixels) 20 to 1280

Line Scan Height Definition: Serial Cmd: Default: Options:

This parameter is only used with the Straight Line modes. It sets the scan height of the straight-line image, and it is expressed in number of pixels. <K529,gain,shutter speed,focus position,symbol type,WOI framing,WOI margin,line scan height,processing> 64 (pixels) 3 to 1024

Processing Definition: Serial Cmd: Default: Options:

This setting defines the amount of time and effort the imager will spend attempting to decode a symbol for each parameter configuration. <K529,gain,shutter speed,focus position,symbol type,WOI framing,WOI margin,line scan height,processing> Medium 0 = Low 1 = Medium 2 = High 3 = Definable

Low The imager will spend a low amount of effort attempting to decode the given symbol for each parameter configuration.

Medium The imager will spend a medium amount of effort attempting to decode the given symbol for each parameter configuration.

High The imager will spend a high amount of effort attempting to decode the given symbol for each parameter configuration.

Definable The processing time for each image frame is defined by the Image Processing Timeout parameter <K245>. 4-10

MINI Hawk Xi High Performance Imager User Manual

Page 75

Calibration

Calibration by ESP ESP’s Calibration view incorporates all the functionality of the <K529> (Calibration Options) command in a single easy-to-use, intuitive interface. This calibration process allows the user much finer control of individual parameters than the calibration routine in EZ Mode or on the Video tab.

Before/During Calibration Before and After tabs give the user an authentic representation of the difference in what the imager “sees” before and after the calibration routine.

Focus, Shutter, Gain, and Image Quality values are all tracked in real-time during the calibration process. Gain, Shutter Speed, and Focal Distance (Capture Settings) are all configurable in the Calibration interface.

Determines the amount of time and effort the imager will spend attempting to decode a symbol for each parameter configuration. (Low, Medium, High, Definable).

Dropdown menu of 1D and 2D symbologies, and a check box for enabling or disabling Composite symbologies.

Initiates the calibration routine. Cancels the calibration process, if necessary.

The Window of Interest section of the Calibration interface allows the user to make precise adjustments to WOI Framing, WOI Margin (in pixels), and the scan height of the straight-line image (in pixels).

MINI Hawk Xi High Performance Imager User Manual

4-11

Page 76

Calibration by ESP

After Calibration Notice the improved image resolution after the calibration process is complete. The Focus, Shutter, Gain, and Quality indicator bars remain stationary at the end of calibration to provide a visual reference for the final values of these four parameters.

The calibration progress bar indicates that the process has been completed.

Saves the optimal configuration parameters determined by calibration results.

4-12

MINI Hawk Xi High Performance Imager User Manual

Page 77

Calibration

Initiating Calibration Calibration can be initiated by serial command, the EZ button, or from the Calibration interface in ESP. A symbol must be in the imager’s field of view during the calibration process. In ESP, the Calibrate button starts the calibration routine.

To initiate calibration by serial command, enter the serial command <@CAL> from a terminal, such as ESP’s Terminal interface. <@CAL> is a calibration routine that emphasizes contrast and readability.

See Calibrate by EZ Button for the EZ button calibration procedure.

MINI Hawk Xi High Performance Imager User Manual

4-13

Page 78

Initiating Calibration

Calibration Progress Indicators During the calibration process, the imager has a number of ways to communicate its progress to the user. The following three types of feedback are the primary ways that the imager communicates calibration progress.

Read Rate LEDs When calibration is initiated through a serial command or the EZ Button, the imager’s Read Rate LEDs indicate calibration progress as follows: LEDs 20% 20%, 40% 20%, 40%, 60% 20%, 40%, 60%, 80% 20%, 40%, 60%, 80%, 100%

Calibration Progress Search Pass in progress. Focus Pass in progress. Medium Pass in progress. Fine-Tune Pass in progress. Calibrated Successfully (holds for green flash duration).

Calibrated Successfully Fine-Tune Pass Medium Pass Focus Pass Search Pass

Beeper/Green Flash The beeper and green LED flash are used to indicate calibration status as shown in the table below: Indicator 2 quick beeps 5 quick beeps 1 long beep 1 sec. Green Flash

4-14

Status Calibration has started. Calibration has failed. Calibration has been completed successfully. Calibration has been completed successfully.

MINI Hawk Xi High Performance Imager User Manual

Page 79

Calibration

Calibration Progress Output to Terminal When initiated by serial command or EZ button, the autocalibration operation will output progress and process information to a terminal if the system is configured to do so.

Terminal Depending upon how the calibration options are configured, the autocalibration process can have up to 5 steps (Quick Focus, Search Pass, Focus Pass, Medium Pass, Fine-Tune Pass). Calibration data is shown in a simple table format under 8 category headings, each of which are defined below. Heading Prog Rating Decode Quality Focus Shutter Gain Locate

Definition Progress indicator with a range of 0 - 100. Indicates percent complete. Rating indicator; higher ratings are more favorable. Number of successful decodes for the pass. Quality indicator; higher ratings are more favorable. Focus position under operation. Shutter setting under operation. Gain setting under operation. Time required to locate symbol, expressed in milliseconds.

Calibration Progress Output Examples (Terminal) Quick Focus This mode is only run if Quick Focus calibration mode is enabled (see Focus Position). Quick Focus calibration mode is designed to quickly locate the focus setting for an object at the center of the imager’s field of view. There is no terminal output for this operation.

Search Pass The purpose of Search Pass is to decode a symbol in as few configurations as possible during calibration. This process is designed to quickly identify symbology type, and any image processing parameters that are already calibrated, as well as determining focus position. Running Search Pass Prog

Rating

Decode

Quality

Focus

Shutter

Gain

Locate

12 14 16 18

0 0 0 2174

0 0 0 1

0 0 0 72

313 313 313 313

250 250 250 250

0 9 18 27

0 0 0 24

MINI Hawk Xi High Performance Imager User Manual

4-15

Page 80

Initiating Calibration

Focus Pass The purpose of Focus Pass is to determine the optimal focal position of the optical system. This is accomplished by determining the inside and outside focus positions and then recording the center position as the desired focal position. Running Focus Pass Prog

Rating

Decode

Quality

Focus

Shutter

Gain

Locate

38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 42 42 42 42 42 42 42 42 42 42 46

0 0 4256 0 4236 0 4236 0 4232 0 2128 0 0 2144 0 0 0 0 0 0 4280 4280 4280 4280 4280 4280 4280 4280 4280 4280 0

0 0 2 0 2 0 2 0 2 0 1 0 0 1 0 0 0 0 0 0 2 2 2 2 2 2 2 2 2 2 0

0 0 48 0 28 0 28 0 24 0 24 0 0 40 0 0 0 0 0 0 72 72 72 72 72 72 72 72 72 72 0

353 353 353 409 409 447 447 492 492 536 536 572 572 572 601 601 601 601 601 601 297 283 270 258 247 236 227 217 209 200 601

250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250

0 9 18 0 9 0 9 0 9 0 9 0 9 18 27 36 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45

0 0 5 0 5 0 4 0 4 0 5 0 0 4 0 0 0 0 0 0 6 5 5 5 5 6 5 5 6 6 0

Inside Focus = 200; Outside Focus = 572; Center Focus = 386

4-16