Communications

ASCII Character Entry Modifier Commands that require ASCII text fields, such as Preamble and Postamble commands, can be sent to the imager as hex pairs. Serial Cmd Format: <Knnnh,00-FF> To enter ASCII fields as hex values (00 to FF), add a lower-case h directly after the command’s K number, and then enter the hex value that corresponds with the desired ASCII character. Example: Consider the Postamble command: Serial Cmd:

<K142,status,postamble character(s)>

Imagine that your application requires the ASCII character > to be the postamble in your symbol decode output. The ASCII characters <, >, and , can only be entered as hex pairs. So, to make > the postamble in your symbol decode output, enter the Postamble command as follows: <K142h,,3E> Note that the “status” field contains only a , . This is because the only field that is being changed is the “postamble character(s)” field. (See Serial Configuration Command Conventions for a more detailed explanation of this command shortcut.)

MINI Hawk Xi High Performance Imager User Manual

3-17

Page 62

Preamble

Preamble Preamble Status Usage: Definition: Serial Cmd: Default: Options:

Useful for identifying and controlling incoming data. For example, defining the preamble as a carriage return and a line feed causes each decoded message to be displayed on its own line. Defines a one to four character data string that can be added to the front of the decoded data. <K141,status,preamble character(s)> Disabled 0 = Disabled 1 = Enabled (within any protocol)

Preamble Characters Serial Cmd: Default: Options:

<K141,status,preamble character(s)> ^M corresponds to: carriage return. To enter control characters within a serial command, hold down the Ctrl key while typing the desired character. Example: <K141,1,CNTL-m> to enter the control character ^M.

Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K141h,,3C> For >: <K141h,,3E> For , : <K141h,,2C>

3-18

MINI Hawk Xi High Performance Imager User Manual

Page 63

Communications

Postamble Postamble Status Usage: Definition: Serial Cmd: Default: Options:

Useful for identifying and controlling incoming data. For example, defining the postamble as a carriage return and a line feed causes each decoded message to be displayed on its own line. Allows the user to enable or disable up to four postamble characters that can be added to the end of the decoded data. <K142,status,postamble character(s)> Enabled 0 = Disabled 1 = Enabled (within any protocol)

Postamble Characters Serial Cmd: Default: Options:

<K142,status,postamble character(s)> ^M^J corresponds to: carriage return/line feed. To enter control characters within a serial command, hold down the control key while typing the desired character. Example: <K142,1,CNTL-m CNTL-j> to enter ^M^J.

Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K142h,,3C> For >: <K142h,,3E> For , : <K142h,,2C>

MINI Hawk Xi High Performance Imager User Manual

3-19

Page 64

Postamble

3-20

MINI Hawk Xi High Performance Imager User Manual

Page 65

4 Calibration Contents Calibration Serial Commands ....................................................................................................... 4-2 Calibration Overview..................................................................................................................... 4-2 Calibration Options ....................................................................................................................... 4-3 Calibration by ESP..................................................................................................................... 4-11 Initiating Calibration ................................................................................................................... 4-13 Additional Notes about Calibration............................................................................................. 4-19

This section shows the MINI Hawk Xi’s calibration options, and explains the different ways that those options can be configured.

MINI Hawk Xi High Performance Imager User Manual

4-1

Page 66

Calibration Serial Commands

Calibration Serial Commands Calibration Options Autocalibrate

<K529,gain,shutter speed,focus position,symbol type,WOI framing,WOI margin,line scan height,processing> <@CAL>

Calibration Overview Autocalibration is one of the most powerful features of the MINI Hawk Xi. The calibration process can be initiated by serial command, EZ button, or ESP user interface. When the imager enters calibration, it runs through an optimization cycle that sets the ideal parameters for reading symbols at the highest possible level of performance. Autocalibration can be specially configured to optimize specific parameters, such as focus, gain, shutter speed, and symbol type. The calibration process consists of five separate phases: quick focus, search pass, focus pass, medium pass, and fine-tune pass. During this process the imager quickly locates configuration setup, defines a calibration range for the configuration parameters, and then tunes those parameters for optimal performance.

4-2

MINI Hawk Xi High Performance Imager User Manual

Page 67

Calibration

Calibration Options This command specifies the operation of the imager’s calibration feature. The default configuration is set up to perform calibration on gain, focus, and symbol type. The default shutter speed setting is disabled, because not all applications require shutter speed, and when it is required, the application-specific settings tend to vary widely. Note: Background Color is part of the calibration process regardless of the calibration setup. After successful completion of the calibration routine, the background color will be set to the appropriate value, depending on the symbol in the field of view. The Illumination Brightness parameter is not part of the calibration process, and it must be configured appropriately prior to calibration.

Gain Definition: Serial Cmd: Default: Options:

When enabled, gain will be calibrated to provide the best available image quality and performance. When disabled, gain is fixed and is not part of the calibration process. <K529,gain,shutter speed,focus position,symbol type,WOI framing,WOI margin,line scan height,processing> Enabled 0 = Disabled 1 = Enabled

Shutter Speed Unless an application is a static setup, the shutter speed setting should be configured by the user based on the application. For dynamic applications, the user should configure the shutter speed setting so the calibration process can optimize the gain for that setting. Serial Cmd: <K529,gain,shutter speed,focus position,symbol type,WOI framing,WOI margin,line scan height,processing> Default: Disabled Options: 0 = Disabled 1 = Enabled 2 = Fast Shutter Note: The following table shows general guidelines for shutter speed configurations based on various line speeds. The configurations shown depend on the imager’s optical configuration, and on symbol element size. Definition:

Shutter Speed 0 - 250 250 - 750 750 - 1500 1500 - 2000 2000 - 2500

Line Speed static 5” / sec 10” / sec 15” / sec 20” / sec

MINI Hawk Xi High Performance Imager User Manual

4-3

Page 68

Calibration Options

Disabled (Shutter Speed) When this feature is disabled, the shutter speed is fixed and is not part of the calibration process.

Enabled (Shutter Speed) When this feature is enabled, shutter speed will be calibrated to provide the best possible image quality and performance.

Fast Shutter The calibration process will concentrate on achieving the fastest possible shutter setting that will still provide good performance. The image quality or contrast may not be as good as what would be achieved with the Enabled setting. The calibration process is not designed to choose the fastest shutter speed that can decode a symbol, but rather to optimize for the fastest shutter speed that still provides good image quality.

4-4

MINI Hawk Xi High Performance Imager User Manual

Page 69

Calibration

Focus Position Definition:

Serial Cmd: Default: Options:

Since focus can be configured by entering the target distance from the imager’s parting line, the user will normally configure the focus setting without needing to calibrate. However, if it is necessary to calibrate the focus distance, there are two methods for doing so: the standard “Search Method”, or a “Quick Focus” method, both of which are defined below. <K529,gain,shutter speed,focus position,symbol type,WOI framing, WOI margin,line scan height,processing> Quick Focus 0 = Disabled 1 = Enabled 2 = Quick Focus

Disabled When this feature is disabled, the focus position is fixed and is not part of the calibration process.

Enabled (Search Method) When this feature is enabled, the focus position will be calibrated to provide the best possible image quality and performance. This method is essentially a search method that attempts to identify the desired focus using a search algorithm that cycles through focus settings to try and locate the desired focus as quickly as possible. This is accomplished when the given symbol in the field of view is decoded. Once a focus distance that will decode the given symbol has been located, the search algorithm will fine-tune the search to locate the “inside” and “outside” focal distances. The final focus distance will be between the “inside” and “outside” values. Note: This method can be time-consuming if the focus is not found on the first pass.

Quick Focus Quick Focus is designed to quickly locate the focus setting for an object in the field of view. This is accomplished with minimal processing of the image by analyzing a histogram of the image frame. Before performing the focus calibration, a value for shutter speed and gain is determined and then the calibration process will step through the focus range of the system, capturing the required number of image frames for each focal position. A histogram is performed on each image frame and the histogram results for each focus position are averaged. When this process is completed, the data is analyzed and the optimal focus position is determined. Note: Quick Focus may not work well for all applications. It is not recommended for applications that use very small symbols.

MINI Hawk Xi High Performance Imager User Manual

4-5

Page 70

Calibration Options

Symbol Type Serial Cmd: Default: Options:

<K529,gain,shutter speed,focus position,symbol type,WOI framing,WOI margin,line scan height,processing> Enabled 0 = Disabled 1 = Enabled

Disabled When this feature is disabled, only the currently-enabled symbologies will be considered during the calibration process.

Enabled When this feature is enabled, autodiscrimination will be in effect during the calibration process. All symbologies that are readable by the imager except PDF417 and Pharmacode will be considered during calibration. Any new symbologies successfully decoded during calibration will remain enabled at the end of the process. All enabled symbologies will remain enabled. For example, assume that only Code 39 is enabled at the beginning of calibration. If a Code 128 symbol is read during calibration, then Code 128, as well as Code 39, will be enabled after the calibration process is complete.

4-6

MINI Hawk Xi High Performance Imager User Manual