The text of a manual · part 10 of 39
MINI Hawk Xi High Performance Imager User Manual, pages 91 to 100
Pages 91 to 100 of 388
The original document is the PDF (6.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan Mini Hawk Xi
Page 91
Read Cycle
Continuous Read 1 Output Usage:
Definition:
Serial Cmd:
Continuous Read 1 Output can be useful in applications where it is not feasible to use a trigger and all succeeding symbols contain different information. It is also effective in applications where the objects are presented by hand. In Continuous Read 1 Output the imager self-triggers whenever it decodes a new symbol or a timeout occurs. If End of Read Cycle is set to Timeout and the symbol doesn’t change, the output is repeated at the end of each timeout period. For example, if Timeout is set to one second, the imager sends the symbol data immediately and repeats the output at intervals of one second for as long as it continues to capture the symbol. If End of Read Cycle is set to New Trigger, the imager will send the current symbol data immediately, but only once. A new symbol appearing in the imager’s range will be read and sent immediately, provided it is not identical to the previous symbol. <K200,1>
Caution: In automated environments, Continuous Read 1 Output is not recommended because there is typically no reliable way to verify that a symbol was missed. Note: If Trigger Mode is set to Continuous Read 1 Output, the imager will behave as if Number of Symbols were set to 1, regardless of the user-defined configuration.
MINI Hawk Xi High Performance Imager User Manual
5-7
Page 92
Trigger Mode and Filter Duration
External Level Initiate Read Cycle: Object #1, moving in front of the detector beam, causes a change in the trigger state, which initiates the read cycle. End Read Cycle: The same object, moving out of the detector beam, causes another change in the trigger state, which ends the read cycle.
Usage:
Definition:
Serial Cmd:
This mode is effective in an application where the speeds of the conveying apparatus are variable and the time the imager spends reading each object is not predictable. It also allows the user to determine if a No Read has occurred. External Level allows the read cycle (active state) to begin when a trigger (change of state) from an external sensing device is received. The read cycle persists until the object moves out of the sensor range and the active trigger state changes again. <K200,2>
Important: Level and Edge apply to the active logic state (Active Open or Active Closed) that exists while the object is in a read cycle, between the rising edge and the falling edge. Rising edge is the trigger signal associated with the appearance of an object. Falling edge is the trigger signal associated with the subsequent disappearance of the object. This applies both to External Level and External Edge.
External Edge Initiate Read Cycle: Object # 1, moving in front of the detector beam, causes a change in the trigger state, which initiates the read cycle. Initiate Second Read Cycle: Object # 2, moving in front of the detector beam, causes another change in the trigger state. This signal initiates a new read cycle and ends the previous read cycle unless Timeout is enabled and a good read or timeout has not occured.
Usage: Definition:
Serial Cmd: 5-8
This mode is highly recommended in any application where conveying speed is constant, or if spacing, object size, or read cycle timeouts are consistent. External Edge, as with Level, allows the read cycle (active state) to begin when a trigger (change of state) from an external sensing device is received. However, the passing of an object out of sensor range does not end the read cycle. The read cycle ends with a good read output, or, depending on the End of Read Cycle setting, a timeout or new trigger occurs. <K200,3> MINI Hawk Xi High Performance Imager User Manual
Page 93
Read Cycle
Serial Data Usage: Definition:
Serial Cmd:
Serial Data is effective in a highly controlled environment where the host knows precisely when the object is in the field of view. It is also useful in determining if a No Read has occurred. In Serial Data, the imager accepts an ASCII character from the host or controlling device as a trigger to start a read cycle. A Serial Data trigger behaves the same as an External Edge trigger. Serial commands are entered inside angle brackets, as shown here: <t>. <K200,4>
Note: In Serial Data, sending a non-delimited start serial character will start a read cycle; however, a non-delimited stop serial character has no effect.
Serial Data and Edge Usage: Definition: Serial Cmd:
Serial Data or External Edge is seldom used but can be useful in an application that primarily uses an external sensing device but occasionally needs to be triggered manually. In this mode the imager accepts either a serial ASCII character or an external trigger pulse to start the read cycle. <K200,5>
Note: In Serial Data, sending a non-delimited start serial character will start a read cycle; however, a non-delimited stop serial character has no effect.
MINI Hawk Xi High Performance Imager User Manual
5-9
Page 94
Trigger Mode and Filter Duration
Leading Edge Trigger Filter Usage: Definition:
Serial Cmd: Default: Options:
Used to ignore spurious triggers when Trigger Mode is set to External Edge or External Level. To consider a change in state on the trigger input, the level must be stable for the trigger filter duration. In an edge mode, the imager will trigger a read cycle if the active state has been uninterrupted for the entire trigger filter duration. In a level mode, the leading edge is filtered such that on an active edge, the state must be held interrupted for the trigger filter duration before a trigger will occur. <K200,trigger mode,leading edge trigger filter,trailing edge trigger filter> 313 (~10 ms) 1 to 65535 (Trigger filter range: 32.0 µs to 2.10 seconds)
Trailing Edge Trigger Filter Usage:
Used to ignore spurious triggers when Trigger Mode is set to External Edge or External Level.
Definition:
To consider a change in state on the trigger input, the level must be stable for the trigger filter duration. In an edge mode, the imager will trigger a read cycle if the active state has been uninterrupted for the entire trigger filter duration. In a level mode, the trailing edge is filtered such that on the falling edge, the state must be held for the trigger filter duration before the trigger will be deemed inactive. <K200,trigger mode,leading edge trigger filter,trailing edge trigger filter> 313 (~10 ms) 1 to 65535 (Trigger filter range: 32.0 µs to 2.10 seconds)
Serial Cmd: Default: Options:
5-10
MINI Hawk Xi High Performance Imager User Manual
Page 95
Read Cycle
External Trigger Polarity Usage: Definition: Serial Cmd: Default: Options:
Allows users to select the trigger polarity that will be used in their application. Determines the active state of the trigger signal applied to the cable input of the imager. <K202,active state> Positive 0 = Negative 1 = Positive
MINI Hawk Xi High Performance Imager User Manual
5-11
Page 96
Serial Trigger
Serial Trigger Usage: Definition:
Allows the user to define the trigger character and delimiters that start and stop the read cycle. A serial trigger is considered an online host command and requires the same command format as all host commands. It must be entered within angle bracket delimiters < > or, in the case of non-delimited triggers, it must define individual start and stop characters.
Serial Trigger Character (Delimited) Usage: Definition:
Allows the user to define the trigger character that initiates the read cycle. A single ASCII host serial trigger character that initiates the read cycle. A delimited trigger character is one that either starts or ends the read cycle and is enclosed by delimiters such as < >. Serial Cmd: <K201,serial trigger character> Default: Space bar Options: Any single ASCII character, including control characters, except NUL (00 in hex), an existing host command character, or an on-line protocol character. Control characters entered on the command line are displayed in the menu as mnemonic characters. Note: Serial Data or Serial Data or External Edge triggering mode must be enabled for Serial Trigger Character to take effect. Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K201h,3C> For >: <K201h,3E> For , : <K201h,2C>
5-12
MINI Hawk Xi High Performance Imager User Manual
Page 97
Read Cycle
Start Trigger Character (Non-Delimited) Usage: Definition:
Serial Cmd: Default: Options:
Useful in applications where different characters are required to start a read cycle. A single ASCII host serial trigger character that starts the read cycle and is not enclosed by delimiters such as < and >. Non-delimited Start characters can be defined and will function according to the trigger event. When defining Start trigger characters, the following rules apply: • In External Edge the imager looks only for the Start trigger character and ignores any Stop trigger character that may be defined. • In External Level the Start trigger character begins the read cycle and the Stop trigger character ends it. Note that even after a symbol has been decoded and the symbol data transmitted, the imager remains in External Level trigger read cycle until a Stop character is received. • In Serial Data or External Edge trigger mode, either a Start trigger character or a hardware trigger can start an edge trigger read cycle. <K229,start character> NUL (00 in hex) (disabled) Two hex digits representing any ASCII character except XON and XOFF.
Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K229h,3C> For >: <K229h,3E> For , : <K229h,2C>
MINI Hawk Xi High Performance Imager User Manual
5-13
Page 98
Stop Trigger Character (Non-Delimited)
Stop Trigger Character (Non-Delimited) Usage: Definition:
Serial Cmd: Default: Options:
Useful in applications where different characters are required to end a read cycle. A single ASCII host serial trigger character that ends the read cycle and is not enclosed by delimiters such as < and >. Non-delimited Stop characters can be defined and will function according to the trigger event. When defining Stop trigger characters, the following rules apply: • In External Edge the imager looks only for the Start trigger character and ignores any Stop trigger character that may be defined. • In External Level the Start trigger character begins the read cycle and the Stop trigger character ends it. Note that even after a symbol has been decoded and the symbol data transmitted, the imager remains in External Level trigger read cycle until a Stop character is received. • In Serial Data or External Edge trigger mode, either a Start trigger character or a hardware trigger can start an edge trigger read cycle. <K230,stop character> NUL (00 in hex) (disabled) Two hex digits representing an ASCII character.
Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K230h,3C> For >: <K230h,3E> For , : <K230h,2C>
5-14
MINI Hawk Xi High Performance Imager User Manual
Page 99
Read Cycle
End of Read Cycle Definition:
The read cycle is the time during which the imager will attempt to capture and decode a symbol. A read cycle can be ended by a timeout, a new trigger, or by the last frame in a capture sequence or a combination of the above.
End of Read Cycle Mode Note: When operating in Continuous Read or Continuous Read 1 Output, the imager is always in the read cycle. Serial Cmd: Default: Options:
<K220,end of read cycle,read cycle timeout> Timeout 0 = Timeout 1 = New Trigger 2 = Timeout or new Trigger 3 = Last Frame 4 = Last Frame or New Trigger
Timeout Usage:
Definition:
Typically used with Serial Data or External Edge and Continuous Read 1 Output. It is effective in highly controlled applications when the maximum length of time between objects can be predicted. It assures that a read cycle ends before the next symbol appears, giving the system extra time to decode and transmit the data to the host. Timeout ends the read cycle, causing the reader to stop reading symbols and send the symbol data or No Read message when the time set in Timeout elapses (times out), if When to Output is set to End of Read Cycle. If in Continuous Read 1 Output, a timeout initiates a new read cycle and allows the same symbol to be read again. With External Edge, Serial Data, or Serial Data or External Edge enabled, a timeout ends the read cycle and symbol data or a No Read message is sent to the host. With External Level enabled, the read cycle does not end until the falling edge trigger occurs or a timeout occurs. The next read cycle does not begin until the next rising edge trigger.
MINI Hawk Xi High Performance Imager User Manual
5-15
Page 100
End of Read Cycle
New Trigger Usage: Definition:
New Trigger is an effective way to end a read cycle when objects move past the reader at irregular intervals (not timing-dependent). New Trigger ends the current read cycle and initiates a new one when a new trigger occurs. New Trigger refers only to a rising edge trigger. With External Edge, Serial Data, or Serial Data or External Edge enabled, an edge or serial trigger ends a read cycle and initiates the next read cycle. In the case of External Level, a falling edge trigger ends the read cycle but the next read cycle does not begin until the occurrence of the next rising edge trigger.
Timeout or New Trigger Usage: Definition:
Useful in applications that require an alternative way to end the read cycle. For example, if an assembly line should stop completely or the intervals between objects are highly irregular. Timeout or New Trigger is identical to Timeout except that a timeout or a new trigger (whichever occurs first) ends the read cycle.
Last Frame Usage: Definition:
Useful in applications in which the number of captures needed can be defined but the timeout duration varies. Last Frame only applies to Rapid Capture Mode.
Last Frame or New Trigger Usage: Definition:
Useful in applications in which line speeds are irregular and a new labelled object could appear before the last frame in a Rapid Capture sequence. Last Frame or New Trigger is identical to New Trigger except that a new trigger or last frame (whichever occurs first) ends the read cycle.
Read Cycle Timeout Definition: Serial Cmd: Default: Options:
5-16
Read Cycle Timeout is the duration of the read cycle. <K220,end of read cycle,read cycle timeout> 200 (x10 ms) 1 to 65535
MINI Hawk Xi High Performance Imager User Manual