Page 191
LVS-7500 Operations Manual Version 20.2.X
Example 1 The entry for ActiveDirectoryLVSAllUsers must be formatted using standard Active Directory syntax. For example:
LVS7500Users is a Group and begins with cn=
ValidationUsers is an Organizational Unit and begins with ou= cn=LVS7500Users,ou=ValidationUsers
The above example is correct given the objects displayed in the following Active Directory window:
LVS-7500 Operations Manual Version 20.2.X
Page 191 of 222
Page 192
LVS-7500 Operations Manual Version 20.2.X
Example 2 The entry for ActiveDirectoryLVSOrgUnit must be formatted using standard Active Directory syntax. The example below is correct given the objects displayed in the Active Directory window below. ou=LVS7500Permissions,ou=LVS Permissions,ou=LVS Systems
LVS-7500 Operations Manual Version 20.2.X
Page 192 of 222
Page 193
LVS-7500 Operations Manual Version 20.2.X
Active Directory User Permissions To manage Active Directory user permissions, follow the steps below. 1. Select Administration Operators from the menu bar.
2. The Operator Administration screen allows you to setup operators and operator permissions. *Active Directory Enabled* appears at the top of the screen to let you know that Active Directory is enabled; this message does not appear when Active Directory is disabled.
3. The buttons at the bottom of the screen are described below: Option Add new operator
Description Click this button to add a new operator. Complete the following fields: Operator ID (short name) Operator name (full name) Password (enter twice). Each password must consist of the following: - At least 8 characters - At least 1 letter from A to Z - At least 1 number from 0 to 9 Select the desired permissions Click Save changes to save your changes or Discard
LVS-7500 Operations Manual Version 20.2.X
Page 193 of 222
Page 194
LVS-7500 Operations Manual Version 20.2.X
Option Change this operator
Delete this operator Discard changes Save changes Done
Description changes to discard and not save your changes Click this button to make changes to an operator’s permissions. Select the operator’s name from the Operators list Click the Change this operator button Make any necessary changes Click the Save Changes button to save your changes or the Discard Changes button to not save your changes Click this button to delete an operator. First, select the operator’s name from the Operators list, and then click the Delete this operator button. Click this button to discard changes made to operator details. Click this button to save changes made to operator details. Click this button after all changes are complete.
4. User permissions are described below: Permission
Description
Allow Create / Edit NEW Job
Allows the operator to create, edit, and delete a job.
Allow Load EXISTING Job
Allows the operator to load and execute existing jobs. This permission does not allow the user to edit existing jobs.
Allow Calibration
Allows the operator to perform calibration.
Allow Administration
Allows the operator access to the “Administration” menu bar feature where operators and operator permissions are set up. See the “Administration” section for more information (Welcome Screen Overview > Administration)
Allow Accept / Replace Errors
Allows the operator to accept or replace errors.
Allow Bypass / MakeReady
Allows the operator the ability to use the “Bypass” and “MakeReady” buttons on the Running screen.
Allow Abort
Allows the operator the ability to abort the execution of a job after a validation error is detected and the “Printing Stopped Error Message” is displayed.
Allow Ignore
Allows the operator the ability to ignore a label validation error after the “Printing Stopped Error Message”* is displayed. Printing will continue with the next label in the job.
Allow Reset Printer
Allows the operator to send a reset printer signal from the LVS® 7500 to the connected printer.
LVS-7500 Operations Manual Version 20.2.X
Page 194 of 222
Page 195
LVS-7500 Operations Manual Version 20.2.X
Appendix G: TCP/IP Control
Basic Production mode functionality of the LVS® 7500 can be controlled using a TCP/IP command set. This provides customers and third party integrators a mechanism for developing custom HMI interfaces using TCP/IP bi-directional communication with the LVS® 7500 system to automate production job execution. To prepare the LVS® 7500 system to accept TCP/IP commands, there are user configurable software settings; refer to the following section for details on implementing the required settings: Appendix A: User Configurable Settings List of User Configurable Settings TCP/IP.
TCP/IP Configuration Settings Setting: Options: Default:
Host none 0.0.0.0
Leave as default value.
Setting: Options: Default:
Mode off Remote XML off
Setting: Options: Default:
Port1 none 0
Mode indicates if the LVS® 7500 is connecting to another system. Use “off” if the LVS® 7500 is not connecting to another system. Use “Remote” if the LVS® 7500 is connecting with a remote computer, such as the LVS® HMI Command Center or a non-LVS® system. All remaining settings (such as Host, Port1, Port2, etc.) do not apply if the LVS® 7500 is not connecting to another system. Enter the port where the first external system will be listening for LVS® data.
Setting: Options: Default:
Port1Filter none none
Setting: Options: Default:
Port2 none 0
Setting: Options: Default:
Port2Filter none none
Specifies the type of information that the LVS® 7500 system will broadcast on the port specified by Port1. This filter is for output from the LVS® 7500 only. Leave this blank to receive all information from the LVS® 7500 system. Enter a comma separated list of Binary Command Byte ID#’s to receive only the feedback information desired. Enter the port where the second external system will be listening for LVS® data. Specifies the type of information that the LVS® 7500 system will broadcast on the port specified by Port2. This filter is for output from the LVS® 7500 only. Leave this blank to receive all information from the LVS® 7500 system. Enter a comma separated list of Binary Command Byte ID#’s to receive only the feedback information desired.
Below is an example of the setting to configure an LVS® 7500 to accept TCP/IP commands: Mode=remote Host=0.0.0.0 Port1=8001 Port1Filter=1,2,3,4,5,7,8,11,12,13,14,28,29 The example for Port1Filter will tell the LVS® 7500 to broadcast all outputs and input command responses except the IP Status (31).
LVS-7500 Operations Manual Version 20.2.X
Page 195 of 222
Page 196
LVS-7500 Operations Manual Version 20.2.X
TCP/IP Commands and Output Data Summary Name
Binary Command Byte ID#
Description
External Command
Data Output
Load Job
1
Load the currently loaded job.
X
Start Run
2
Start running the currently loaded job.
X
Stop Run
3
Stop running.
X
Start Bypass
4
Enter Bypass mode if the system is currently running.
X
End Bypass
5
Exit from Bypass mode.
X
Sector Error
7
Data output from the LVS® 7500 system with this command byte ID# will include information about a failed sector inspection. If multiple sectors fail during a given repeat, there will be a unique sector error output message for each individual sector.
X
Log Line
8
Data output from the LVS® 7500 system with this command byte ID# will include all inspection information from every sector for the given repeat.
X
Continue Run
11
Continue the last run of the currently loaded job.
X
Make Ready
12
Enter Make Ready mode.
X
Reset Alarms
13
Reset the alarms.
X
Exit To Main
14
Exit from the currently loaded job to the main screen.
X
Close out job
15
Close out the currently loaded job.
X
Import Job
16
Import the job from the Import folder.
X
Load Job from Archive
17
Load job from the Archive folder.
X
Set MatchTo
28
Enter the current match-to strings to replace the given field designator.
X
Reset Available
29
Query the LVS® 7500 system to discover if the Reset Alarms button is active (used prior to a Reset Alarms command).
X
IP Status
31
Continuous status data updates from the LVS® 7500 system.
X
LVS-7500 Operations Manual Version 20.2.X
Page 196 of 222
Page 197
LVS-7500 Operations Manual Version 20.2.X
TCP/IP Commands Protocol The TCP/IP Commands sent to an LVS® 7500 have the following format: <Binary Command Byte ID#><ASCII String> Where:
<Binary Command Byte ID#> is the unique command ID associated with the desired operation. Refer to the following sections for the binary command byte IDs for each support LVS® 7500 command. The commands are sent as binary bytes not ASCII. An example of a binary command to import a job would be a byte value 0x16 hex. The production command to import a job is: 0x16 “Jobname0221.”
<ASCII String> consists of command-specific data, if applicable. An example of command-specific data in the previous example would be the job name. The text string “Jobname0221” is the job name and would be loaded if it existed in the Import folder.
The response from the LVS® 7500 system will have the following format if the operation is successful: <Binary Command Byte ID#> Where <Binary Command Byte ID#> will be identical to the command ID that the LVS® 7500 received. For example, if the command to import a job named “Jobname0221” was sent. 0x16 “Jobname0221” If the job was successfully imported the response from the LVS® 7500 would be the command byte that was sent: 0x16 The response from the LVS® 7500 will have the following format if the operation fails: <Binary Command Byte ID#><ASCII String> <Binary Command Byte ID#> will be identical to the command ID that the LVS® 7500 received. <ASCII String> is an ASCII string describing the error. If the job name did not exist in the Import folder, the response from the LVS® 7500 would be: 0x16 ERROR: Job not found in import folder
LVS-7500 Operations Manual Version 20.2.X
Page 197 of 222
Page 198
LVS-7500 Operations Manual Version 20.2.X
Load Job The “Load Job” command will load the desired job on all connected LVS® 7500 systems. The command format is: <Binary Command Byte ID#><ASCII String> For the “Load Job” command, the <Binary Command Byte ID#> is equal to a binary 1 (0x01 hex), and the <ASCII String> designates the name of an existing job. The command format is then: <0x01 hex><Existing Job Name> The LVS® 7500 response when the command completes successfully would be: <0x01 hex> The LVS® 7500 response when the command fails would be: <0x01 hex><ASCII Error Message>
Start Running The “Start Running” command will start the currently loaded job on the LVS® 7500 system. The command format is: <Binary Command Byte ID#><ASCII String> For the “Start Job” command, the <Binary Command Byte ID#> is equal to a binary 2 (0x02 hex), and the <ASCII String> is blank. The command format is then: <0x02 hex> The LVS® 7500 response when the command completes successfully would be: <0x02 hex> The LVS® 7500 response when the command fails would be: <0x02 hex><ASCII Error Message>
Stop Running The “Stop Running” command will stop the desired job on the LVS® 7500 system. The command format is: <Binary Command Byte ID#><ASCII String> For the “Stop Running” command, the <Binary Command Byte ID#> is equal to a binary 3 (0x03 hex), and the <ASCII String> is blank. The command format is then: <0x03 hex> LVS-7500 Operations Manual Version 20.2.X
Page 198 of 222
Page 199
LVS-7500 Operations Manual Version 20.2.X
The LVS® 7500 response when the command completes successfully would be: <0x03 hex> The LVS® 7500 response when the command fails would be: <0x03 hex><ASCII Error Message>
Continue Last Run The “Continue Last Run” command is valid only after a job has been loaded. Sending this command will initiate inspections and the results will be appended to the most recent run file (CSV file) instead of creating a new run. The command format is: <Binary Command Byte ID#> For the “Continue Last Run” command, the <Binary Command Byte ID#> is equal to a binary 11 (0x0b hex), and the <ASCII String> is blank. The command format is then: <0x0b hex> The LVS® 7500 response when the command completes successfully would be: <0x02 hex> The LVS® 7500 response when the command fails would be: <0x0b hex><ASCII Error Message>
Make Ready The “Make Ready” command is valid only after a job has been loaded. Sending this command will load initiate Make Ready mode for the currently loaded job. The command format is: <Binary Command Byte ID#> For the “Make Ready” command, the <Binary Command Byte ID#> is equal to a binary 12 (0x0c hex), and the <ASCII String> is blank. The command format is then: <0x0c hex> The LVS® 7500 response when the command completes successfully would be: <0x0c hex> The LVS® 7500 response when the command fails would be: <0x0c hex><ASCII Error Message>
LVS-7500 Operations Manual Version 20.2.X
Page 199 of 222
Page 200
LVS-7500 Operations Manual Version 20.2.X
Start Bypass The “Start Bypass” command is valid only after a job has been loaded and is currently running. Sending this command will put the LVS® 7500 system into Bypass mode. The command format is: <Binary Command Byte ID#><ASCII String> For the “Start Bypass” command, the <Binary Command Byte ID#> is equal to a binary 4 (0x04 hex), and the <ASCII String> is blank. The command format is then: <0x04 hex> The LVS® 7500 response when the command completes successfully would be: <0x04 hex> The LVS® 7500 response when the command fails would be: <0x04 hex><ASCII Error Message>
End Bypass The “End Bypass” command is valid only after a job has been loaded and is currently running in Bypass mode. Sending this command will take the LVS® 7500 system out of Bypass mode and back into normal run mode. The command format is: <Binary Command Byte ID#><ASCII String> For the “End Bypass” command, the <Binary Command Byte ID#> is equal to a binary 5 (0x05 hex), and the <ASCII String> is blank. The command format is then: <0x05 hex> The LVS® 7500 response when the command completes successfully would be: <0x05 hex> The LVS® 7500 response when the command fails would be: <0x05 hex><ASCII Error Message>
Reset Alarms The “Reset Alarms” command is the equivalent of clicking the “Reset alarms” button on the LVS® 7500 system. The command format is: <Binary Command Byte ID#><ASCII String>
LVS-7500 Operations Manual Version 20.2.X