Page 151

LVS-7500 Operations Manual Version 20.2.X inspected labels that were not Accepted 4=supports Mode 1 and Mode 2 reversal Default: 0=do not regrade previously inspected labels Setting: SetRunStatusOnSetup Options: none Default: 0

SetRunStatusOnSetup setting should only be configured by a qualified LVS® representative.

Setting: SetRunStatusOutput Options: none Default: 1

SetRunStatusOutput setting should only be configured by a qualified LVS® representative.

Setting: ShaftDiameter Options: none Default: 1.146

ShaftDiameter setting should only be configured by a qualified LVS® representative.

Setting: ShowRollerOnReverse Options: 0=off 1=ON Default: 0=off Setting: SimulateStopMotion Options: 0=off 1=ON Default: 0=off Setting: StopMotionDelay Options: none Default: 40

ShowRollerOnReverse determines if a Roll-to-Roll will be displayed when running in reverse. 0 means show the actual image when running. 1 means show the Roll-to-Roll image when running in reverse. SimulateStopMotion setting should only be configured by a qualified LVS® representative.

Setting: StopTimeout Options: none Default:

This is the minimum allowed distance that LVS® has determined that the stop motion output signal can be sent without missing any outputs. This should not be changed unless instructed by a qualified LVS® representative. StopTimeout sets a delay timer before stopping the inspection when the Stop button is clicked when running. It allows the printer to finish printing a label before terminating the inspection.

Grading Setting: AutoSetupGrade1D Options: 0=read 1D bar codes 1=grade 1D bar codes Default: 1=grade 1D bar codes Setting: AutoSetupGrade2D Options: 0=read 2D bar codes 1=grade 2D bar codes Default: 1=grade 2D bar codes Setting: DeductForBlemish Options: 0=off 1=ON

LVS-7500 Operations Manual Version 20.2.X

AutoSetupGrade1D setting should only be configured by a qualified LVS® representative.

AutoSetupGrade2D setting should only be configured by a qualified LVS® representative.

Lowers the ISO overall grade based on the severity of a barcode blemish.

Page 151 of 222

Page 152

LVS-7500 Operations Manual Version 20.2.X

Default:

0=off

Setting: LightFrequency Options: 0=red light (660nm) 1=white light Default: 0=red light (660nm) Setting: MaxDecodesToGrade Options: none Default: 10

LightFrequency setting should only be configured by a qualified LVS® representative.

Setting: MinimumPassScore Options: none Default: 1.5

MinimumPassScore activates an error signal and logs an error in the log.

Setting: MinimumWarningScore Options: none Default: 0

MinimumWarningScore activates a warning that alerts an operator without generating an error in the log. This value is user configurable.

Setting: Override1DAperture Options: none Default: 0

Override1DAperture setting should only be configured by a qualified LVS® representative.

MaxDecodesToGrade is the amount of decodable scan lines it takes to grade a bar code. ANSI standards require at least 10 lines.

ImageSaver Setting: DumpColorSlabPath Options: none Default: none

DumpColorSlabPath setting should only be configured by a qualified LVS® representative.

Setting: Path Options: none Default: none

This is a path to be specified to store images to. A target folder must be made and the path to that target folder is to be put directly after the path=. As an example, Path=C:\Images would need a folder called “Images” under the C:\ drive. It will store all incoming images to that directory. This will show a pop up window reminding the operator that it was set as it will consume massive processing power and HDD space if left with a path specified. Range setting should only be configured by a qualified LVS® representative.

Setting: Range Options: none Default: none Setting: SaveLabelRepeat Options: none Default: 0

LVS-7500 Operations Manual Version 20.2.X

0 means save every unsynchronized label. 1 means save every synchronized label. 2,3,4,5 mean save every label multiple of (example 2 every other, 3 every third, etc) synchronized.

Page 152 of 222

Page 153

LVS-7500 Operations Manual Version 20.2.X

Lumenera Setting: Brightness Options: none Default: 1.5

Brightness setting should only be configured by a qualified LVS® representative.

Setting: Exposure Options: none Default: 0.3

Exposure is the exposure setting of a Lumenera USB camera.

Setting: FixedSpeed Options: none Default: 0

FixedSpeed is the speed of an external belt or conveyor in feet per minute.

Setting: Gain Options: none Default: 1.0

Gain is used on certain Lumenera cameras.

Setting: Gain0 Options: none Default: 1.0

Gain0, Gain1, Gain2 and Gain3 are the four gain values for the line-scan camera sensors.

Setting: Gain1 Options: none Default: 1.0

Gain0, Gain1, Gain2 and Gain3 are the four gain values for the line-scan camera sensors.

Setting: Gain2 Options: none Default: 1.0

Gain0, Gain1, Gain2 and Gain3 are the four gain values for the line-scan camera sensors.

Setting: Gain3 Options: none Default: 1.0

Gain0, Gain1, Gain2 and Gain3 are the four gain values for the line-scan camera sensors.

Setting: MaxLumeneraSpeed Options: none Default: 60

MaxLumeneraSpeed is the maximum frames that a Lumenera USB camera can run at per second.

OCR Setting: MaxHorizontalShift Options: none Default: 0

MaxHorizontalShift follows the movement of printed characters.

Setting: OCRDebug Options: 0=off 1=save only OCR error images with scores 2=save all OCR images with scores -1=save OCR images as cropped images without

OCRDebug setting should only be configured by a qualified LVS® representative.

LVS-7500 Operations Manual Version 20.2.X

Page 153 of 222

Page 154

LVS-7500 Operations Manual Version 20.2.X

Default:

scores 0=off

Setting: RatioMethod Options: 0=normal 1=DontForceRatio2to3 2=Learn and use ratio from font Default: 0=off Setting: TouchMode Options: 0=off 1=compensate for slight gaps 2=compensate for large gaps 3=use customer-specific features Default: 0=off

RatioMethod setting should only be configured by a qualified LVS® representative.

TouchMode setting should only be configured by a qualified LVS® representative.

OCV Setting: MinimumPassScore Options: none Default: 40

MinimumPassScore sets the default minimum pass score for OCV.

Setting: MinimumWarningScore Options: none Default: 60

MinimumWarningScore sets the default minimum warning score for OCV.

Paths Setting: DesignArchive Options: none Default: .\Design\Archive

Archive folder path for Design mode templates.

Setting: DesignTemplates Options: none Default: .\Design\Templates

Templates folder path for Design mode templates.

Setting: ProductionArchive Options: none Default: .\Production\Archive

Archive folder path for Production mode jobs.

Setting: ProductionImport Options: none Default: .\Production\Import

Import folder path for Production mode jobs.

Setting: ProductionJobs Options: none Default: .\Production\Jobs

Jobs folder path for Production mode jobs.

LVS-7500 Operations Manual Version 20.2.X

Page 154 of 222

Page 155

LVS-7500 Operations Manual Version 20.2.X

Setting: ProductionOutput Options: none Default: .\Production\Output

Output folder path for Production mode jobs.

PopUp Setting: ShowCameraWarning Options: 0=off 1=ON Default: 1=ON Setting: ShowNotAssessedWarning Options: 0=off 1=ON Default: 0=off Setting: ShowNotSyncedWarning Options: 0=off 1=ON Default: 0=off

ShowCameraWarning allows the software to show a popup message when the number specified in the CpuUtilizationWarning is reached. ShowNotAssessedWarning allows the software to show a popup message when labels are not being inspected. ShowNotSyncedWarning setting should only be configured by a qualified LVS® representative.

Preset Setting: Default Options: none Default: Med

Default setting should only be configured by a qualified LVS® representative.

Setting: Options: Default:

High none 85,85,5,85,5,25,59,50,39,0

High setting should only be configured by a qualified LVS® representative.

Setting: Options: Default:

Low none 65,65,15,65,24,25,59,50,39,0

Low setting should only be configured by a qualified LVS® representative.

Setting: Options: Default:

Med none 75,75,15,75,15,25,59,50,39,0

Med setting should only be configured by a qualified LVS® representative.

Setting: Options: Default:

UseFeature none 0

UseFeature setting should only be configured by a qualified LVS® representative.

Increment none 3

Increment setting should only be configured by a qualified LVS® representative.

Printronix Setting: Options: Default:

LVS-7500 Operations Manual Version 20.2.X

Page 155 of 222

Page 156

LVS-7500 Operations Manual Version 20.2.X

Setting: Options: Default:

MinimumStep none 32

MinimumStep setting should only be configured by a qualified LVS® representative.

Setting: Options: Default:

ReprintTimeout none 10

ReprintTimeout setting should only be configured by a qualified LVS® representative.

Setting: Options:

SystemType 0=Normal 1=Design 2=Production 0= Normal

SystemType setting should only be configured by a qualified LVS® representative.

Default:

ProcessFlow Setting: Options: Default:

MaxFilesToImport none 0

Setting: Options:

UseCleanupMode 0=off 1=ON 0=off

Default:

Enter the maximum number of zip files allowed to be present in the IMPORT folder at one time. A value of 0 indicates that there is no limit to the number of zip files in the IMPORT folder. In Production mode, setting UseCleanupMode to 1 will delete the zip file from the IMPORT folder once loaded.

Simulation Setting: Options:

HealthCheck setting should only be configured by a qualified LVS® representative.

Default: Setting: Options: Default:

HealthCheck 0=off 1=ON 0=off Path none none

Setting: Options: Default:

ProcessPath none none

This is the path to a directory of stored images.

Setting: Options: Default:

Speed none 50

Speed is how fast the system will simulate web motion. A positive value indicates feet/minute. A negative value specifies the maximum CPU percentage to use.

LVS-7500 Operations Manual Version 20.2.X

This is the path to a directory of stored images.

Page 156 of 222

Page 157

LVS-7500 Operations Manual Version 20.2.X

Sync Setting: Options: Default:

AutoSyncSpanFactor none 6

AutoSyncSpanFactor sets the width of the sync span in automatic setup. The Sync span is set to AutoSyncSpanFactor * HopX.

Setting: Options:

FastSync tells the system to not resync when the "Start" button in pushed. This is needed on LVS® 7500 systems to not miss the first label.

Default: Setting: Options: Default:

FastSync 0=off 1=ON 0=off HopX none 0.125

Setting: Options: Default:

HopY none 0.125

HopY tracks the movement of the labels in the vertical direction.

Setting: Options: Default:

Log none none

Log setting should only be configured by a qualified LVS® representative.

HopX tracks the movement of the labels in the horizontal direction.

System Setting: Options: Default: Setting: Options: Default: Setting: Options: Default: Setting: Options: Default: Setting: Options: Default: Setting: Options:

AcceptReplaceInputTimer 0=off 1=ON 0=off ApplyStopMotionWhenNotRunning 0=off 1=ON 0=off Audible Alarm none 34

AcceptReplaceInputTimer setting should only be configured by a qualified LVS® representative.

AutoLogin 0=off 1=ON 0=off AutoMakeReady none 0

The Automatic Login feature allows a user to automatically log in to the LVS® 7500 software without entering an Operator ID and Password. AutoMakeReady setting should only be configured by a qualified LVS® representative.

AutoSetup 0=do not use AutoSetup 1=ask if AutoSetup should be used 2=always use AutoSetup without

AutoSetup tells the software when to use the LVS® 7500 automated process when creating a new job.

LVS-7500 Operations Manual Version 20.2.X

Sends the stop motion signal to the light tower when not on the Running Screen, MakeReady Screen, or Edit screen. Tells the software what I/O line the system should use to trigger a beep.

Page 157 of 222

Page 158

LVS-7500 Operations Manual Version 20.2.X

Default: Setting: Options: Default:

asking 3=carton mode 0=do not use AutoSetup AutoSetup3Margin none 0.5

Setting: Options: Default:

AutoSetupSideMatch none 32

AutoSetupSideMatch setting should only be configured by a qualified LVS® representative.

Setting: Options: Default:

AutoStop none 0

AutoStop turns on autostop for stopping after a specified label count.

Setting: Options: Default:

Base64Trailer none 0

Base64Trailer setting should only be configured by a qualified LVS® representative.

Setting: Options:

BuzzerDuration 10ms 20ms 100ms 200ms 500ms 1 second 2 seconds 3 seconds 4 seconds 5 seconds 6 seconds 7 seconds 8 seconds 9 seconds 10 seconds hold 1 second BuzzerIOLine 3=follow error 4=follow stop motion 3=follow error CameraSpeedWarning none 90

This specifies the buzzer duration. Use “hold” to require a manual reset.

Default: Setting: Options: Default: Setting: Options: Default:

LVS-7500 Operations Manual Version 20.2.X

AutoSetup3Margin setting should only be configured by a qualified LVS® representative.

BuzzerIOLine setting should only be configured by a qualified LVS® representative.

CameraSpeedWarning tells the software when to show a warning message if the camera gets to the specified speed.

Page 158 of 222

Page 159

LVS-7500 Operations Manual Version 20.2.X

Setting: Options: Default:

CameraToError none 54

CameraToError is a special function used as of version 5.

Setting: Options: Default: Setting: Options: Default:

ClearPrompts 0=off 1=ON 0=off ConsecutiveReadLines none 5

Setting: Options: Default:

CpuUtilizationWarning none 75

If set to zero (default), the system will re-use the most recently entered data for prompts. If set to non-zero, the computer will start with blanks and the operator must fill in all data. ConsecutiveReadLines is how large a gap must be between two adjacent barcodes during autosetup to separate them into two separate sectors. CpuUtilizationWarning tells the software when to show a warning message if the CPU usage gets to the specified value.

Setting: Options:

Gap off ON off

Default:

Setting: Options:

HideAlarmMatrix 0=off 1=ON 0=off IgnoreHealthCheck

Default: Setting: Options: 0=performs HealthCheck on 1D and 2D codes 1=performs HealthCheck on 2D codes and grading on 1D codes 2=performs HealthCheck on 1D codes and grading on 2D codes 3=ignores the HealthCheck code Default: 0 Setting: InactivityTimeout Options: none Default: 0 Setting: Options: Default: Setting: Options:

LastSystemType Design Production Design LvsContactSensor 0=not installed 5=5” sensor installed 8=8” sensor installed

LVS-7500 Operations Manual Version 20.2.X

The Gap=OFF/ON is a specialized reporting ability that if turned on, any jump in a sequential number in a positive direction is called a GAP and is allowed. If the GAP is turned off then this same condition would result in a Sequence error. Hides the Alarm Matrix, preventing the adjustment of the Alarm Matrix parameters.

IgnoreHealthCheck setting should only be configured by a qualified LVS® representative.

Inactivity Timeout automatically logs out any user if the system is left idle for the defined amount of time. This value is defined in minutes. Records last active mode when dual mode functionality is active. Setting should not be changed. LvsContactSensor is for LVS® technician use only. It designates the type of contact sensor used with LVS® 7500 systems.

Page 159 of 222

Page 160

LVS-7500 Operations Manual Version 20.2.X

Default:

0=not installed

Setting: Options: Default:

LvsContactSizeY none 96

LvsContactSizeY setting should only be configured by a qualified LVS® representative.

Setting: Options: Default:

MajorityDelta none 0

MajorityDelta setting should only be configured by a qualified LVS® representative.

Setting: Options: Default:

MakeReady none none

Setting: Options: Default:

MaxCpuBusyPercent none 100

Setting: Options: Default:

MaxErrPerSec none 30

Setting: Options: Default:

MaxThumbnails none 1000

MakeReady is used when the operator needs to ignore a specified string in a sector at the beginning of a job. For instance, type in the word VOID and the software will ignore that word at the beginning of the job only. MaxCpuBusyPercent is the maximum allowable CPU usage as a percentage. If the CPU usage exceeds this value, sectors will be Not Assessed (NA) until the CPU utilization drops to a point equal to this value. Default is 100. MaxErrPerSec prevents the software from failing when inundated with errors. It will not create more than 30 thumbnails of errors per second. After 30 errors, no more thumbnails will be collected until the next second. MaxThumbnails is the amount of thumbnail images that can be reviewed while the system is running.

Setting: Options: Default:

MinimumPreserveLength none 10

MinimumPreserveLength setting should only be configured by a qualified LVS® representative.

Setting: Options: Default:

MinimumScrapPerRun none 0

MinimumScrapPerRun setting should only be configured by a qualified LVS® representative.

Setting: Options: Default:

MonitorInterval none 1000

MonitorInterval setting should only be configured by a qualified LVS® representative.

Setting: Options: Default:

MonthsBeforePasswordChange none 0

MonthsBeforePasswordChange prompts users for passwords to be changed after the number of months entered.

LVS-7500 Operations Manual Version 20.2.X

Page 160 of 222