Page 131
LVS-7500 Operations Manual Version 20.2.X
Setting: Signal Output Line Options: I/O line 1 I/O line 2 I/O line 3 I/O line 4 Default: I/O line 3
This sets the I/O line to activate for this error condition. The default value is I/O line 3, which corresponds to the red light.
Setting: StopMotion Options: do not stop immediately after 2 in a row after 3 in a row after 4 in a row after 5 in a row after 6 in a row after 7 in a row after 8 in a row after 9 in a row after 10 in a row Default: immediately
This specifies if this error condition should also trigger activation of the stop motion signal.
Alarm (Grade Warning) Setting: Signal Duration Options: 10ms 20ms 100ms 200ms 500ms 1 second 5 seconds hold Default: 100ms
This specifies the signal duration.
Setting: Signal Output Line Options: I/O line 1 I/O line 2 I/O line 3 I/O line 4 Default: I/O line 3
This sets the I/O line to activate for this error condition. The default value is I/O line 3, which corresponds to the red light.
LVS-7500 Operations Manual Version 20.2.X
Page 131 of 222
Page 132
LVS-7500 Operations Manual Version 20.2.X
Setting: StopMotion Options: do not stop immediately after 2 in a row after 3 in a row after 4 in a row after 5 in a row after 6 in a row after 7 in a row after 8 in a row after 9 in a row after 10 in a row Default: immediately
This specifies if this error condition should also trigger activation of the stop motion signal.
Alarm (Matrix) Setting: Signal Duration Options: 10ms 20ms 100ms 200ms 500ms 1 second 5 seconds hold Default: 100ms
This specifies the signal duration.
Setting: Signal Output Line Options: I/O line 1 I/O line 2 I/O line 3 I/O line 4 Default: I/O line 3
This sets the I/O line to activate for this error condition. The default value is I/O line 3, which corresponds to the red light.
Setting: StopMotion Options: do not stop immediately after 2 in a row after 3 in a row after 4 in a row after 5 in a row after 6 in a row after 7 in a row after 8 in a row after 9 in a row after 10 in a row Default: immediately
This specifies if this error condition should also trigger activation of the stop motion signal.
LVS-7500 Operations Manual Version 20.2.X
Page 132 of 222
Page 133
LVS-7500 Operations Manual Version 20.2.X
Alarm (Mismatch) Setting: Signal Duration Options: 10ms 20ms 100ms 200ms 500ms 1 second 5 seconds hold Default: 100ms
This specifies the signal duration.
Setting: Signal Output Line Options: I/O line 1 I/O line 2 I/O line 3 I/O line 4 Default: I/O line 3
This sets the I/O line to activate for this error condition. The default value is I/O line 3, which corresponds to the red light.
Setting: StopMotion Options: do not stop immediately after 2 in a row after 3 in a row after 4 in a row after 5 in a row after 6 in a row after 7 in a row after 8 in a row after 9 in a row after 10 in a row Default: immediately
This specifies if this error condition should also trigger activation of the stop motion signal.
Alarm (Missing FNC1) Setting: Signal Duration Options: 10ms 20ms 100ms 200ms 500ms 1 second 5 seconds hold Default: 100ms
LVS-7500 Operations Manual Version 20.2.X
This specifies the signal duration.
Page 133 of 222
Page 134
LVS-7500 Operations Manual Version 20.2.X
Setting: Signal Output Line Options: I/O line 1 I/O line 2 I/O line 3 I/O line 4 Default: I/O line 3
This sets the I/O line to activate for this error condition. The default value is I/O line 3, which corresponds to the red light.
Setting: StopMotion Options: do not stop immediately after 2 in a row after 3 in a row after 4 in a row after 5 in a row after 6 in a row after 7 in a row after 8 in a row after 9 in a row after 10 in a row Default: immediately
This specifies if this error condition should also trigger activation of the stop motion signal.
Alarm (No Read) Setting: Signal Duration Options: 10ms 20ms 100ms 200ms 500ms 1 second 5 seconds hold Default: 100ms
This specifies the signal duration.
Setting: Signal Output Line Options: I/O line 1 I/O line 2 I/O line 3 I/O line 4 Default: I/O line 3
This sets the I/O line to activate for this error condition. The default value is I/O line 3, which corresponds to the red light.
LVS-7500 Operations Manual Version 20.2.X
Page 134 of 222
Page 135
LVS-7500 Operations Manual Version 20.2.X
Setting: StopMotion Options: do not stop immediately after 2 in a row after 3 in a row after 4 in a row after 5 in a row after 6 in a row after 7 in a row after 8 in a row after 9 in a row after 10 in a row Default: immediately
This specifies if this error condition should also trigger activation of the stop motion signal.
Alarm (Not Assessed) Setting: Signal Duration Options: 10ms 20ms 100ms 200ms 500ms 1 second 5 seconds hold Default: 100ms
This specifies the signal duration.
Setting: Signal Output Line Options: I/O line 1 I/O line 2 I/O line 3 I/O line 4 Default: I/O line 3
This sets the I/O line to activate for this error condition. The default value is I/O line 3, which corresponds to the red light.
Setting: StopMotion Options: do not stop immediately after 2 in a row after 3 in a row after 4 in a row after 5 in a row after 6 in a row after 7 in a row after 8 in a row after 9 in a row after 10 in a row Default: immediately
This specifies if this error condition should also trigger activation of the stop motion signal.
LVS-7500 Operations Manual Version 20.2.X
Page 135 of 222
Page 136
LVS-7500 Operations Manual Version 20.2.X
Alarm (Not Synced) Setting: Signal Duration Options: 10ms 20ms 100ms 200ms 500ms 1 second 5 seconds hold Default: 100ms
This specifies the signal duration.
Setting: Signal Output Line Options: I/O line 1 I/O line 2 I/O line 3 I/O line 4 Default: I/O line 3
This sets the I/O line to activate for this error condition. The default value is I/O line 3, which corresponds to the red light.
Setting: StopMotion Options: do not stop immediately after 2 in a row after 3 in a row after 4 in a row after 5 in a row after 6 in a row after 7 in a row after 8 in a row after 9 in a row after 10 in a row Default: immediately
This specifies if this error condition should also trigger activation of the stop motion signal.
Alarm (Quality) Setting: Signal Duration Options: 10ms 20ms 100ms 200ms 500ms 1 second 5 seconds hold Default: 100ms
LVS-7500 Operations Manual Version 20.2.X
This specifies the signal duration.
Page 136 of 222
Page 137
LVS-7500 Operations Manual Version 20.2.X
Setting: Signal Output Line Options: I/O line 1 I/O line 2 I/O line 3 I/O line 4 Default: I/O line 3
This sets the I/O line to activate for this error condition. The default value is I/O line 3, which corresponds to the red light.
Setting: StopMotion Options: do not stop immediately after 2 in a row after 3 in a row after 4 in a row after 5 in a row after 6 in a row after 7 in a row after 8 in a row after 9 in a row after 10 in a row Default: immediately
This specifies if this error condition should also trigger activation of the stop motion signal.
Alarm (Range) Setting: Signal Duration Options: 10ms 20ms 100ms 200ms 500ms 1 second 5 seconds hold Default: 100ms
This specifies the signal duration.
Setting: Signal Output Line Options: I/O line 1 I/O line 2 I/O line 3 I/O line 4 Default: I/O line 3
This sets the I/O line to activate for this error condition. The default value is I/O line 3, which corresponds to the red light.
LVS-7500 Operations Manual Version 20.2.X
Page 137 of 222
Page 138
LVS-7500 Operations Manual Version 20.2.X
Setting: StopMotion Options: do not stop immediately after 2 in a row after 3 in a row after 4 in a row after 5 in a row after 6 in a row after 7 in a row after 8 in a row after 9 in a row after 10 in a row Default: immediately
This specifies if this error condition should also trigger activation of the stop motion signal.
Alarm (Sequence) Setting: Signal Duration Options: 10ms 20ms 100ms 200ms 500ms 1 second 5 seconds hold Default: 100ms
This specifies the signal duration.
Setting: Signal Output Line Options: I/O line 1 I/O line 2 I/O line 3 I/O line 4 Default: I/O line 3
This sets the I/O line to activate for this error condition. The default value is I/O line 3, which corresponds to the red light.
Setting: StopMotion Options: do not stop immediately after 2 in a row after 3 in a row after 4 in a row after 5 in a row after 6 in a row after 7 in a row after 8 in a row after 9 in a row after 10 in a row Default: immediately
This specifies if this error condition should also trigger activation of the stop motion signal.
LVS-7500 Operations Manual Version 20.2.X
Page 138 of 222
Page 139
LVS-7500 Operations Manual Version 20.2.X
Alarm (Stop Motion) Setting: Signal Duration Options: 10ms 20ms 100ms 200ms 500ms 1 second 5 seconds hold Default: 100ms
This specifies the signal duration.
Setting: Signal Output Line Options: I/O line 1 I/O line 2 I/O line 3 I/O line 4 Default: I/O line 3
This sets the I/O line to activate for this error condition. The default value is I/O line 3, which corresponds to the red light.
Setting: StopMotion Options: do not stop immediately after 2 in a row after 3 in a row after 4 in a row after 5 in a row after 6 in a row after 7 in a row after 8 in a row after 9 in a row after 10 in a row Default: immediately
This specifies if this error condition should also trigger activation of the stop motion signal.
Alarm (Wrong Length) Setting: Signal Duration Options: 10ms 20ms 100ms 200ms 500ms 1 second 5 seconds hold Default: 100ms
LVS-7500 Operations Manual Version 20.2.X
This specifies the signal duration.
Page 139 of 222
Page 140
LVS-7500 Operations Manual Version 20.2.X
Setting: Signal Output Line Options: I/O line 1 I/O line 2 I/O line 3 I/O line 4 Default: I/O line 3
This sets the I/O line to activate for this error condition. The default value is I/O line 3, which corresponds to the red light.
Setting: StopMotion Options: do not stop immediately after 2 in a row after 3 in a row after 4 in a row after 5 in a row after 6 in a row after 7 in a row after 8 in a row after 9 in a row after 10 in a row Default: immediately
This specifies if this error condition should also trigger activation of the stop motion signal.
ApertureGrading Setting: ApertureScaling1D Options: none Default: 0.8
The aperture settings are used to calculate bar code grading and should not be changed unless requested by a qualified LVS® representative.
Setting: ApertureScaling2D Options: none Default: 1.0
The aperture settings are used to calculate bar code grading and should not be changed unless requested by a qualified LVS® representative.
Setting: IgnoreGS1Rules Options: 0=off 1=ON Default: 0=off
The aperture settings are used to calculate bar code grading and should not be changed unless requested by a qualified LVS® representative.
Setting: SharpenMatrixSize Options: none Default: 9
The aperture settings are used to calculate bar code grading and should not be changed unless requested by a qualified LVS® representative.
Setting: SharpenValue Options: none Default: 35
The aperture settings are used to calculate bar code grading and should not be changed unless requested by a qualified LVS® representative.
LVS-7500 Operations Manual Version 20.2.X
Page 140 of 222