Page 81
Code 128/EAN 128
Function 1 Output Status Serial Cmd: Default: Options:
<K464,status,min length,max length,function 1 output status,function 1 output character> Enabled 0 = Disabled 1 = Enabled
Disabled
Bar Code Configuration Mode
Enabled (Default)
Save Settings
Function 1 Output Character Serial Cmd: Default: Options:
<K464,status,min length,max length,function 1 output status,function 1 output character> , Any ASCII character
Bar Code Configuration Mode
5-24
, (comma) (Default)
Save Settings
HS-1 Handheld Scanner User’s Manual
Page 82
Symbologies
Code 93 Usage: Definition: Serial Cmd: Default: Options:
Used in some clinical applications. Code 93 is a variable-length, continuous symbology employing four element widths. Each Code 93 character has nine modules that may be either black or white. Each character contains three bars and three spaces. <K475,status,0,minimum symbol length> Enabled 0 = Disabled 1 = Enabled
Bar Code Configuration Mode
Disabled
Enabled (Default)
Save Settings
HS-1 Handheld Scanner User’s Manual
5-25
Page 83
Code 93
Minimum Symbol Length (Code 93) Definition:
Serial Cmd: Default: Options:
Specifies the minimum number of characters that the HS-1 will recognize, not including the start and stop check characters. The HS-1 ignores any symbol smaller than the specified length. Note: When setting Minimum Symbol Length to any value other than 0, add 1 to account for a reserved space. For example, if your symbol has 3 characters, set Symbol Length to 4. <K475,status,0,minimum symbol length> 10 0 to 32
Bar Code Configuration Mode
5-26
10 (Default)
Save Settings
HS-1 Handheld Scanner User’s Manual
Page 84
Symbologies
GS1 DataBar (RSS) Note: GS1 DataBar symbologies were previously known as “Reduced Space Symbology”, or “RSS”.
DataBar Omnidirectional (RSS-14) Note: DataBar Omnidirectional was previously known as “RSS-14”. Usage: Definition:
Serial Cmd: Default: Options:
Used in the grocery, retail, and prescription drug industries where 14-digit EAN item identification may be needed. DataBar Omnidirectional is a minimum length symbology that encodes 14 digits, including a 1-digit indicator. DataBar Omnidirectional is 96 modules wide. It can be stacked in two rows, it can read omnidirectionally if printed in full height, or horizontally if height-truncated for small marking. <K482,status> Disabled 0 = Disabled 1 = Enabled
Bar Code Configuration Mode
Disabled (Default)
Enabled
Save Settings
HS-1 Handheld Scanner User’s Manual
5-27
Page 85
GS1 DataBar (RSS)
DataBar Limited (RSS Limited) Note: DataBar Limited was previously known as “RSS Limited”. Usage: Definition: Serial Cmd: Default: Options:
DataBar Limited is designed to be read by laser scanners and CCD readers. It is not recommended for omnidirectional slot scanners. Encodes a smaller 14-digit symbol (74 modules wide) that is not omnidirectional. <K483,status> Disabled 0 = Disabled 1 = Enabled
Bar Code Configuration Mode
Disabled (Default)
Enabled
Save Settings
5-28
HS-1 Handheld Scanner User’s Manual
Page 86
Symbologies
DataBar Expanded (RSS Expanded) Note: DataBar Expanded was previously known as “RSS Expanded”. Usage: Definition: Serial Cmd: Default: Options:
Used to encode primary and supplementary data in retail point-of-sale and other applications. DataBar Expanded is a variable length symbology that can encode supplementary information in addition to the 14-digit EAN item identification number and is capable of encoding up to 74 numeric or 41 alphabetic characters. <K484,status> Disabled 0 = Disabled 1 = Enabled
Bar Code Configuration Mode
Disabled (Default)
Enabled
Save Settings
HS-1 Handheld Scanner User’s Manual
5-29
Page 87
MSI Code
MSI Code Status (MSI Code) Usage: Definition: Serial Cmd: Default: Options:
Used for inventory control and the identification of storage containers and locations in warehouse environments. MSI Code is a numeric, continuous symbology in which each character consists of four bits in a binary format. <K486,status,check character mode,check character output status, 0,minimum symbol length> Disabled 0 = Disabled 1 = Enabled
Bar Code Configuration Mode
Disabled (Default)
Enabled
Save Settings
5-30
HS-1 Handheld Scanner User’s Manual
Page 88
Symbologies
Check Character Mode (MSI Code) Definition: Serial Cmd: Default: Options:
This field is set to perform a Modulus 10 calculation by default. It can also be set to perform a Double Modulus 10 calculation. <K486,status,check character mode,check character output status, 0,minimum symbol length> Modulus 10 1 = Modulus 10 2 = Double Modulus 10
Bar Code Configuration Mode
Modulus 10 (Default)
Double Modulus 10
Save Settings
HS-1 Handheld Scanner User’s Manual
5-31
Page 89
MSI Code
Check Character Output Status (MSI Code) Definition: Serial Cmd: Default: Options:
When this field is enabled, the HS-1 will output the check digit with symbol data. When disabled, the HS-1 will not output the check digit with symbol data. <K486,status,check character mode,check character output status, 0,minimum symbol length> Disabled 0 = Disabled 1 = Enabled
Bar Code Configuration Mode
Disabled (Default)
Enabled
Save Settings
5-32
HS-1 Handheld Scanner User’s Manual
Page 90
Symbologies
Minimum Symbol Length (MSI Code) Definition: Serial Cmd: Default: Options:
This field specifies the minimum number of characters the HS-1 will recognize, including a check character. <K486,status,check character mode,check character output status, 0,minimum symbol length> 6 0 to 32
Bar Code Configuration Mode
HS-1 Handheld Scanner User’s Manual
6 (Default)
Save Settings
5-33