The text of a manual · part 8 of 15
HS-1 Handheld Scanner User Manual, pages 71 to 80
Pages 71 to 80 of 145
The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan HS-1
Page 71
Codabar
Check Character Output (Codabar) Definition:
Serial Cmd: Default: Options:
When this field is disabled and a check character calculation is enabled, the HS-1 will strip the verified check character from the symbol data output. This condition must be accounted for if a minimum length is also being used. When enabled, the HS-1 will output the check character as part of the symbol data. This condition must be accounted for if a minimum length is also being used. <K471,status,0,start/stop output status,0,symbol length status,symbol length,check character status,check character output> Disabled 0 = Disabled 1 = Enabled
Bar Code Configuration Mode
Disabled (Default)
Enabled
Save Settings
5-14
HS-1 Handheld Scanner User’s Manual
Page 72
Symbologies
Interleaved 2 of 5 Usage:
Definition:
Serial Cmd: Default: Options:
Interleaved 2 of 5 has been popular because it is the most dense symbology for printing numeric characters less than 10 characters in length; however, Microscan does not recommend this symbology for any new applications because of inherent problems such as truncation. A dense, continuous, self-checking, numeric symbology. Characters are paired together so that each character has five elements, two wide and three narrow, representing numbers 0 through 9, with the bars representing the first character and the interleaved spaces representing the second character. (A check character is highly recommended). <K472,status,check character status,check character output status,symbol length #1,symbol length #2,guard bar,range mode status> Enabled 0 = Disabled 1 = Enabled
Bar Code Configuration Mode
Disabled
Enabled (Default)
Save Settings
HS-1 Handheld Scanner User’s Manual
5-15
Page 73
Interleaved 2 of 5
Check Character Status (Interleaved 2 of 5) Usage: Definition: Serial Cmd: Default: Options:
This option is not typically used, but it can be enabled for additional security in applications where the host requires redundant check character verification. An error correcting routine in which the check character is added. <K472,status,check character status,check character output status,symbol length #1,symbol length #2,guard bar,range mode status> Disabled 0 = Disabled 1 = Enabled
Bar Code Configuration Mode
Disabled (Default)
Enabled
Save Settings
5-16
HS-1 Handheld Scanner User’s Manual
Page 74
Symbologies
Check Character Output Status (Interleaved 2 of 5) Definition: Serial Cmd: Default: Options:
When enabled, a check character is sent along with the symbol data for added data security. <K472,status,check character status,check character output status,symbol length #1,symbol length #2,guard bar,range mode status> Disabled 0 = Disabled 1 = Enabled
Bar Code Configuration Mode
Disabled (Default)
Enabled
Save Settings
HS-1 Handheld Scanner User’s Manual
5-17
Page 75
Interleaved 2 of 5
Symbol Length #1 (Interleaved 2 of 5) Usage: Definition: Serial Cmd: Default: Options:
Useful in applications where I 2/5 symbols of a specific length are required. The Symbol Length # 1 field is one of two fields against which the decoded symbol is compared before accepting it as valid or rejecting it. <K472,status,check character status,check character output status,symbol length #1,symbol length #2,guard bar,range mode status> 16 0 to 128
Bar Code Configuration Mode
5-18
16 (Default)
Save Settings
HS-1 Handheld Scanner User’s Manual
Page 76
Symbologies
Symbol Length #2 (Interleaved 2 of 5) Usage: Definition: Serial Cmd: Default: Options:
Useful in applications where I 2/5 symbols of a specific length are required. The Symbol Length # 2 field is one of two fields against which the decoded symbol is compared before accepting it as valid or rejecting it. <K472,status,check character status,check character output status,symbol length #1,symbol length #2,guard bar,range mode status> 6 0 to 128
Bar Code Configuration Mode
6 (Default)
Save Settings
Rules The Range Mode and Symbol Length parameters define several symbol length requirement options. Range Mode Disable Disable Disable Disable Enable Enable Enable
Length 1 0 >0 0 >0 0 >0 0
Enable
>0
Enable
>0
Length 2 Required Symbol Length 0 Any 0 Exactly Length 1 >0 Exactly Length 2 >0 Exactly Length 1 or Length 2 0 Any 0 0 to Length 1 >0 0 to Length 2 Same value as Length 1 to maximum symbol length Length 1 >0 and not the Length 1 < or = required length < or = Length 2 same as or Length 1 Length 2 < or = required length < or = Length 1
HS-1 Handheld Scanner User’s Manual
5-19
Page 77
Interleaved 2 of 5
Guard Bar (Interleaved 2 of 5) Definition:
Serial Cmd: Default: Options:
A guard bar is a heavy bar surrounding the printed Interleaved 2 of 5 symbol. It is usually 2x to 4x the width of the wide bar, and creates a quiet zone of 8x to 15x the minimum space element. This is useful to prevent false data output, which can occur with highly tilted or skewed symbols. <K472,status,check character status,check character output status,symbol length #1,symbol length #2,guard bar,range mode status> Disabled 0 = Disabled 1 = Enabled
Bar Code Configuration Mode
Disabled (Default)
Enabled
Save Settings
Guard Bar Example
5-20
HS-1 Handheld Scanner User’s Manual
Page 78
Symbologies
Range Mode Status (Interleaved 2 of 5) Definition: Serial Cmd: Default: Options:
The Range Mode and Length parameters define several symbol length requirement options. <K472,status,check character status,check character output status,symbol length #1,symbol length #2,guard bar,range mode status> Enabled 0 = Disabled 1 = Enabled
Disabled The Length parameters define the exact symbol length required. If neither matches the decoded symbol then the symbol is rejected.
Bar Code Configuration Mode
Disabled
Save Settings
Enabled Symbol Length # 1 and Symbol Length # 2 are combined to form a range of lengths that are considered valid symbol lengths for Interleaved 2 of 5. Symbols that fall outside this range are rejected. Either length can form the start or end of the range.
Bar Code Configuration Mode
HS-1 Handheld Scanner User’s Manual
Enabled (Default)
Save Settings
5-21
Page 79
Code 128/EAN 128
Code 128/EAN 128 Usage: Definition: Serial Cmd: Default: Options:
Code 128 is a smaller symbology useful in applications with limited space and high-security requirements. A very dense alphanumeric symbology. It encodes all 128 ASCII characters, it is continuous, has variable length, and uses multiple element widths measured edge to edge. <K464,status,min length,max length,function 1 output status,function 1 output character> Enabled 0 = Disabled 1 = Enabled
Bar Code Configuration Mode
Disabled
Enabled (Default)
Save Settings
Enabled The following conditions are true when Code 128/EAN 128 is Enabled: • All Code 128-based symbols, including EAN/UCC-128, are decoded and output. • If Symbology ID output is enabled, the symbology identifier always follows the AIM standard. • Function 1 parameters only take effect if an EAN/UCC-128 symbol is decoded. They apply optional formatting to EAN/UCC-128 symbols by outputting the specified character wherever an identifier separator is found.
5-22
HS-1 Handheld Scanner User’s Manual
Page 80
Symbologies
Minimum Length (Code 128/EAN 128) Definition: Serial Cmd: Default: Options:
This field specifies the number of characters that the scanner will recognize, not counting start, stop and check digit characters. The scanner ignores any symbol smaller than the specified length. <K464,status,min length,max length,function 1 output status,function 1 output character> 1 1 to 48
Bar Code Configuration Mode
1 (Default)
Save Settings
Maximum Length (Code 128/EAN 128) Definition: Serial Cmd: Default: Options:
This field specifies the number of characters that the scanner will recognize, not counting start, stop and check digit characters. The scanner ignores any symbol longer than the specified length. <K464,status,min length,max length,function 1 output status,function 1 output character> 48 1 to 48
Bar Code Configuration Mode
HS-1 Handheld Scanner User’s Manual
48 (Default)
Save Settings
5-23