Page 61
Code 39
Code 39 Usage: Definition: Serial Cmd: Default: Options:
Code 39 is the most widely used non-retail 1D symbology. An alphanumeric symbology with unique start/stop code patterns, composed of 9 black and white elements per character, 3 of which are wide. <K470,status,check character status,check character output status,0,0, minimum symbol length,full ASCII set> Enabled 0 = Disabled 1 = Enabled
Bar Code Configuration Mode
Disabled
Enabled (Default)
Save Settings
5-4
HS-1 Handheld Scanner User’s Manual
Page 62
Symbologies
Check Character Status (Code 39) Definition: Serial Cmd: Default: Options:
When enabled, the HS-1 will verify a Modulus 10 check character in order to identify the decode as successful. <K470,status,check character status,check character output status, 0,0,minimum symbol length,full ASCII set> Disabled 0 = Disabled 1 = Enabled
Bar Code Configuration Mode
Disabled (Default)
Enabled
Save Settings
HS-1 Handheld Scanner User’s Manual
5-5
Page 63
Code 39
Check Character Output Status (Code 39) Usage: Definition:
Serial Cmd: Default: Options:
Check Character Output Status, when added to the symbol, provides additional data security. When enabled, the check character is read and output along with the symbol data. When disabled, symbol data is output without the check character. Note: With Check Character Output Status and an External or Serial trigger option enabled, an invalid check character calculation will cause a No Read message to be transmitted at the end of the read cycle. <K470,status,check character status,check character output status, 0,0,minimum symbol length,full ASCII set> Disabled 0 = Disabled 1 = Enabled
Bar Code Configuration Mode
Disabled (Default)
Enabled
Save Settings
5-6
HS-1 Handheld Scanner User’s Manual
Page 64
Symbologies
Minimum Symbol Length (Code 39) Usage: Definition: Serial Cmd: Default: Options:
Minimum Symbol Length helps prevent truncations and increases data integrity by ensuring that only one symbol length will be accepted. Specifies the exact number of characters that the HS-1 will recognize (this does not include start and stop characters and check characters). The HS-1 ignores any symbology that is less than the specified length. <K470,status,check character status,check character output status,0,0,minimum symbol length,full ASCII set> 0 0 to 32
Bar Code Configuration Mode
HS-1 Handheld Scanner User’s Manual
0 (Default)
Save Settings
5-7
Page 65
Code 39
Full ASCII Set (Code 39) Usage:
Definition:
Serial Cmd: Default: Options:
Must be enabled when reading characters outside the standard character set (0-9, A-Z, etc.) The user must know in advance whether or not to use the Full ASCII Set option. Since Full ASCII Set requires two code words to encode one character, it is less efficient. Standard Code 39 encodes 43 characters; zero through nine, capital “A” through capital “Z”, minus symbol, plus symbol, forward slash, space, decimal point, dollar sign, and percent symbol. When Full ASCII Set is enabled, the HS-1 can read the full ASCII character set, from 0 to 255. <K470,status,check character status,check character output status,0,0,minimum symbol length,full ASCII set> Disabled 0 = Disabled 1 = Enabled
Bar Code Configuration Mode
Disabled (Default)
Enabled
Save Settings
5-8
HS-1 Handheld Scanner User’s Manual
Page 66
Symbologies
Codabar Usage: Definition: Serial Cmd: Default: Options:
Used in photo-finishing and library applications. Previously used in medical applications, but not typically used in newer medical applications. Codabar is a 16-bit character set (0 through 9, and the characters $, :, /, ., +, and –) with start/stop codes and at least two distinctly different bar widths. <K471,status,0,start/stop output status,0,symbol length status,symbol length,check character status,check character output> Enabled 0 = Disabled 1 = Enabled
Bar Code Configuration Mode
Disabled
Enabled (Default)
Save Settings
HS-1 Handheld Scanner User’s Manual
5-9
Page 67
Codabar
Start/Stop Output Status (Codabar) Definition:
Serial Cmd: Default: Options:
When enabled, the start and stop characters will be present in the data output of the decoded symbol. When disabled, the start and stop characters will not be present in the data output of the decoded symbol. Note: Because the start and stop characters are included as part of the data, the characters must be included as part of the length in a fixed length mode of operation. <K471,status,0,start/stop output status,0,symbol length status,symbol length,check character status,check character output> Enabled 0 = Disabled 1 = Enabled
Bar Code Configuration Mode
Disabled
Enabled (Default)
Save Settings
5-10
HS-1 Handheld Scanner User’s Manual
Page 68
Symbologies
Symbol Length Status (Codabar) Definition: Serial Cmd: Default: Options:
When set to Any/Minimum, any symbol length is considered valid. When set to Fixed, the HS-1 will check the symbol length against the Symbol Length Status parameter. <K471,status,0,start/stop output status,0,symbol length status,symbol length,check character status,check character output> Any/Minimum 0 = Any/Minimum 1 = Fixed
Bar Code Configuration Mode
Any/Minimum (Default)
Fixed
Save Settings
HS-1 Handheld Scanner User’s Manual
5-11
Page 69
Codabar
Symbol Length (Codabar) Definition:
Serial Cmd: Default: Options:
Specifies the number of characters that the HS-1 will recognize, including start and stop check characters. The Note: When setting Symbol Length to any value other than 0, add 2 to account for reserved spaces. For example, if your symbol has 3 characters, set Symbol Length to 5. Note: If Symbol Length is set to 0 and Symbol Length Status is set to Any/ Minimum, all symbol lengths are decoded. <K471,status,0,start/stop output status,0,symbol length status,symbol length,check character status,check character output> 6 0 to 32
Bar Code Configuration Mode
5-12
6 (Default)
Save Settings
HS-1 Handheld Scanner User’s Manual
Page 70
Symbologies
Check Character Status (Codabar) Definition:
Serial Cmd: Default: Options:
When disabled, the HS-1 will not perform any character checking calculations on decoded Codabar symbols. When set to Modulus 16, the HS-1 will perform a Modulus 16 check character calculation on the symbol. If the symbol does not pass this calculation, it will not be decoded. <K471,status,0,start/stop output status,0,symbol length status,symbol length,check character status,check character output> Disabled 0 = Disabled 1 = Enabled (Modulus 16)
Bar Code Configuration Mode
Disabled (Default)
Enabled (Modulus 16)
Save Settings
HS-1 Handheld Scanner User’s Manual
5-13