The text of a manual · part 6 of 15
HS-1 Handheld Scanner User Manual, pages 51 to 60
Pages 51 to 60 of 145
The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan HS-1
Page 51
Read Cycle by ESP
Read Cycle by ESP
To open nested options, single-click the +. To change a setting, double-click the setting and use your cursor to scroll through the options.
4-2
HS-1 Handheld Scanner User’s Manual
Page 52
Read Cycle
Read Cycle Serial Commands Trigger Mode Hand Presentation Timing No Read Message Beeper Volume
<K203,trigger mode> <K205,time between identical decodes> <K714,status,No Read message> <K752,beeper mode>
HS-1 Handheld Scanner User’s Manual
4-3
Page 53
Trigger Mode
Trigger Mode Definition: Serial Cmd: Default: Options:
Allows the user to determine whether the scanner will be in a continuous read mode or a triggered mode. <K203,trigger mode> Triggered Mode 0 = Continuous / Hand Presentation Mode 1 = Triggered Mode
Continuous / Hand Presentation Mode The trigger is disabled, the scanner is always in the read cycle, and it will attempt to decode and output every scan. The Hand Presentation Timing parameters, <K205>, take effect to control how often the scanner will output the same symbol data, and how long the illumination will stay on.
Save Settings Bar Code Configuration Mode
Continuous / Hand Presentation Mode
Triggered Mode A read cycle is initiated by activating the handle trigger. The read cycle ends and illumination turns off when the trigger is released or when a symbol is decoded.
Save Settings Bar Code Configuration Mode
4-4
Triggered Mode (Default)
HS-1 Handheld Scanner User’s Manual
Page 54
Read Cycle
Hand Presentation Timing Time Between Identical Decodes Definition:
Serial Cmd: Default: Options:
In Continuous / Hand Presentation Mode, this parameter specifies how often the scanner will output the same symbol data. When a symbol is read, it is output immediately, and the Time Between Identical Decodes timer is started. The same symbol will not be output again until the Time Between Identical Decodes timer expires. When set to 0, the reader will output every decode, as fast as possible, with no delay. <K205,time between identical decodes> 0 0 – 65535 (0.1 second increments)
Bar Code Configuration Mode
0 (Default)
Save Settings
HS-1 Handheld Scanner User’s Manual
4-5
Page 55
No Read Message
No Read Message Usage: Definition:
Used in applications where the host needs serial verification that a symbol has not been read. When enabled, and if no symbol has been decoded before timeout or the end of the read cycle, the No Read message will be transmitted to the host.
No Read Status Serial Cmd: Default: Options:
<K714,status,No Read message> Enabled 0 = Disabled 1 = Enabled
Bar Code Configuration Mode
Disabled
Enabled (Default)
Save Settings
No Read Message Definition: Serial Cmd: Default: Options:
Any combination of ASCII characters can be defined as the No Read message. <K714,status,No Read message> NOREAD 1 to 20 ASCII characters.
Bar Code Configuration Mode
NOREAD (Default)
Save Settings 4-6
HS-1 Handheld Scanner User’s Manual
Page 56
Read Cycle
Beeper Volume Definition: Serial Cmd: Default: Options:
Allows the user to determine beeper volume. <K752,beeper mode> High 0 = Off 1 = Medium 2 = High
Bar Code Configuration Mode
Off
Medium
High (Default)
Save Settings
HS-1 Handheld Scanner User’s Manual
4-7
Page 57
Beeper Volume
4-8
HS-1 Handheld Scanner User’s Manual
Page 58
5 Symbologies Contents Symbologies by ESP.................................................................................................................... 5-2 Symbologies Serial Commands ................................................................................................... 5-3 Code 39........................................................................................................................................ 5-4 Codabar........................................................................................................................................ 5-9 Interleaved 2 of 5........................................................................................................................ 5-15 Code 128/EAN 128 .................................................................................................................... 5-22 Code 93...................................................................................................................................... 5-25 GS1 DataBar (RSS) ................................................................................................................... 5-27 MSI Code ................................................................................................................................... 5-30 Plessey Code ............................................................................................................................. 5-34 Industrial 2 of 5........................................................................................................................... 5-37 UPC/EAN ................................................................................................................................... 5-43 China Postal Code ..................................................................................................................... 5-53 PDF417 ...................................................................................................................................... 5-56 Symbology Identifier................................................................................................................... 5-57
This section describes the various symbol types that can be decoded by the HS-1. See the following sites for additional symbology information: http://www.aimglobal.org/standards/aimpubs.asp http://barcodes.gs1us.org/dnn_bcec/Default.aspx?tabid=82
HS-1 Handheld Scanner User’s Manual
5-1
Page 59
Symbologies by ESP
Symbologies by ESP
To open nested options, single-click the +.
To change a setting, double-click the setting and use your cursor to scroll through the options.
5-2
HS-1 Handheld Scanner User’s Manual
Page 60
Symbologies
Symbologies Serial Commands Code 128/EAN 128
<K464,status,0,minimum symbol length,1,1,0,application record separator character> Code 39 <K470,status,check character status,check character output status, 0,0,minimum symbol length,full ASCII set> Codabar <K471,status,0,start/stop match output status,0,symbol length status, symbol length,check character status,check character output status> Interleaved 2 of 5 <K472,status,check character status,check character output status, symbol length #1,symbol length #2,guard bar,range mode status> Code 93 <K475,status,0,minimum symbol length> PDF417 <K476,status> DataBar Omnidirectional (RSS-14) <K482,status> DataBar Limited (RSS Limited) <K483,status> DataBar Expanded (RSS <K484,status> Expanded) MSI Code <K486,status,check character mode,check character output status, 0,minimum symbol length> Plessey Code <K487,status,check character output status,0,minimum symbol length> Industrial 2 of 5 <K488,status,check character status,check character output status, format,symbol length #1,symbol length #2> UPC/EAN <K489,UPC-A status,UPC-E status,EAN-8 status,EAN-13 status, supplementals required,supplemental 2 status,supplemental 5 status, UPC-A as EAN-13,UPC-E as UPC-A,EAN-8 as EAN-13> China Postal Code <K498,status,check digit mode,min length,max length> Symbology Identifier <K753,0,symbology identifier status>
HS-1 Handheld Scanner User’s Manual
5-3