Page 51

Read Cycle by ESP

Read Cycle by ESP

To open nested options, single-click the +. To change a setting, double-click the setting and use your cursor to scroll through the options.

4-2

HS-1 Handheld Scanner User’s Manual

Page 52

Read Cycle

Read Cycle Serial Commands Trigger Mode Hand Presentation Timing No Read Message Beeper Volume

<K203,trigger mode> <K205,time between identical decodes> <K714,status,No Read message> <K752,beeper mode>

HS-1 Handheld Scanner User’s Manual

4-3

Page 53

Trigger Mode

Trigger Mode Definition: Serial Cmd: Default: Options:

Allows the user to determine whether the scanner will be in a continuous read mode or a triggered mode. <K203,trigger mode> Triggered Mode 0 = Continuous / Hand Presentation Mode 1 = Triggered Mode

Continuous / Hand Presentation Mode The trigger is disabled, the scanner is always in the read cycle, and it will attempt to decode and output every scan. The Hand Presentation Timing parameters, <K205>, take effect to control how often the scanner will output the same symbol data, and how long the illumination will stay on.

Save Settings Bar Code Configuration Mode

Continuous / Hand Presentation Mode

Triggered Mode A read cycle is initiated by activating the handle trigger. The read cycle ends and illumination turns off when the trigger is released or when a symbol is decoded.

Save Settings Bar Code Configuration Mode

4-4

Triggered Mode (Default)

HS-1 Handheld Scanner User’s Manual

Page 54

Read Cycle

Hand Presentation Timing Time Between Identical Decodes Definition:

Serial Cmd: Default: Options:

In Continuous / Hand Presentation Mode, this parameter specifies how often the scanner will output the same symbol data. When a symbol is read, it is output immediately, and the Time Between Identical Decodes timer is started. The same symbol will not be output again until the Time Between Identical Decodes timer expires. When set to 0, the reader will output every decode, as fast as possible, with no delay. <K205,time between identical decodes> 0 0 – 65535 (0.1 second increments)

Bar Code Configuration Mode

0 (Default)

Save Settings

HS-1 Handheld Scanner User’s Manual

4-5

Page 55

No Read Message

No Read Message Usage: Definition:

Used in applications where the host needs serial verification that a symbol has not been read. When enabled, and if no symbol has been decoded before timeout or the end of the read cycle, the No Read message will be transmitted to the host.

No Read Status Serial Cmd: Default: Options:

<K714,status,No Read message> Enabled 0 = Disabled 1 = Enabled

Bar Code Configuration Mode

Disabled

Enabled (Default)

Save Settings

No Read Message Definition: Serial Cmd: Default: Options:

Any combination of ASCII characters can be defined as the No Read message. <K714,status,No Read message> NOREAD 1 to 20 ASCII characters.

Bar Code Configuration Mode

NOREAD (Default)

Save Settings 4-6

HS-1 Handheld Scanner User’s Manual

Page 56

Read Cycle

Beeper Volume Definition: Serial Cmd: Default: Options:

Allows the user to determine beeper volume. <K752,beeper mode> High 0 = Off 1 = Medium 2 = High

Bar Code Configuration Mode

Off

Medium

High (Default)

Save Settings

HS-1 Handheld Scanner User’s Manual

4-7

Page 57

Beeper Volume

4-8

HS-1 Handheld Scanner User’s Manual

Page 58

5 Symbologies Contents Symbologies by ESP.................................................................................................................... 5-2 Symbologies Serial Commands ................................................................................................... 5-3 Code 39........................................................................................................................................ 5-4 Codabar........................................................................................................................................ 5-9 Interleaved 2 of 5........................................................................................................................ 5-15 Code 128/EAN 128 .................................................................................................................... 5-22 Code 93...................................................................................................................................... 5-25 GS1 DataBar (RSS) ................................................................................................................... 5-27 MSI Code ................................................................................................................................... 5-30 Plessey Code ............................................................................................................................. 5-34 Industrial 2 of 5........................................................................................................................... 5-37 UPC/EAN ................................................................................................................................... 5-43 China Postal Code ..................................................................................................................... 5-53 PDF417 ...................................................................................................................................... 5-56 Symbology Identifier................................................................................................................... 5-57

This section describes the various symbol types that can be decoded by the HS-1. See the following sites for additional symbology information: http://www.aimglobal.org/standards/aimpubs.asp http://barcodes.gs1us.org/dnn_bcec/Default.aspx?tabid=82

HS-1 Handheld Scanner User’s Manual

5-1

Page 59

Symbologies by ESP

Symbologies by ESP

To open nested options, single-click the +.

To change a setting, double-click the setting and use your cursor to scroll through the options.

5-2

HS-1 Handheld Scanner User’s Manual

Page 60

Symbologies

Symbologies Serial Commands Code 128/EAN 128

<K464,status,0,minimum symbol length,1,1,0,application record separator character> Code 39 <K470,status,check character status,check character output status, 0,0,minimum symbol length,full ASCII set> Codabar <K471,status,0,start/stop match output status,0,symbol length status, symbol length,check character status,check character output status> Interleaved 2 of 5 <K472,status,check character status,check character output status, symbol length #1,symbol length #2,guard bar,range mode status> Code 93 <K475,status,0,minimum symbol length> PDF417 <K476,status> DataBar Omnidirectional (RSS-14) <K482,status> DataBar Limited (RSS Limited) <K483,status> DataBar Expanded (RSS <K484,status> Expanded) MSI Code <K486,status,check character mode,check character output status, 0,minimum symbol length> Plessey Code <K487,status,check character output status,0,minimum symbol length> Industrial 2 of 5 <K488,status,check character status,check character output status, format,symbol length #1,symbol length #2> UPC/EAN <K489,UPC-A status,UPC-E status,EAN-8 status,EAN-13 status, supplementals required,supplemental 2 status,supplemental 5 status, UPC-A as EAN-13,UPC-E as UPC-A,EAN-8 as EAN-13> China Postal Code <K498,status,check digit mode,min length,max length> Symbology Identifier <K753,0,symbology identifier status>

HS-1 Handheld Scanner User’s Manual

5-3