The text of a manual · part 5 of 15
HS-1 Handheld Scanner User Manual, pages 41 to 50
Pages 41 to 50 of 145
The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan HS-1
Page 41
Host Port Connections
Parity, Host Port Usage: Definition: Serial Cmd: Default: Options:
Only changed if necessary to match host setting. An error detection routine in which one data bit per character is set to 1 or 0 so that the total number of bits in the data field is either even or odd. <K100,baud rate,parity,stop bits,data bits> Even 0 = None 1 = Even 2 = Odd
Bar Code Configuration Mode
None
Even (Default)
Odd
Save Settings
3-6
HS-1 Handheld Scanner User’s Manual
Page 42
Communications
Stop Bits, Host Port Usage: Definition: Serial Cmd: Default: Options:
Only changed if necessary to match host setting. One or two bits added to the end of each character to indicate the end of the character. <K100,baud rate,parity,stop bits,data bits> One 0 = One 1 = Two
Bar Code Configuration Mode
One (Default)
Two
Save Settings
HS-1 Handheld Scanner User’s Manual
3-7
Page 43
Host Port Connections
Data Bits, Host Port Usage: Definition: Serial Cmd: Default: Options:
Only changed if necessary to match host setting. One or two bits added to the end of each character to indicate the end of the character. <K100,baud rate,parity,stop bits,data bits> Seven 0 = Seven 1 = Eight
Bar Code Configuration Mode
Seven (Default)
Eight
Save Settings
3-8
HS-1 Handheld Scanner User’s Manual
Page 44
Communications
Host Port Protocol Usage:
In general, the point-to-point protocols will work well in most applications. They require no address and must use RS-232 or RS-422 communications standards. Definition: Protocols define the sequence and format in which information is transferred between the HS-1 and the host. Serial Cmd: <K140,protocol> Default: Point-to-Point Options: 0 = Point-to-Point 1 = Point-to-Point with RTS/CTS Note: The preamble <K141> and postamble <K142> character strings can be used to frame the decoded data in both protocol modes.
Point-to-Point (Standard) Usage: Definition: Serial Cmd:
Used only with RS-232 or RS-422. Standard Point-to-Point requires no address and sends the data to the host whenever it is available, without a request or handshake from the host. <K140,0>
Bar Code Configuration Mode
Point-to-Point (Default)
Save Settings
Point-to-Point with RTS/CTS Usage:
Definition: Serial Cmd:
An HS-1 initiates a data transfer with an RTS (request-to-send) transmission. The host, when ready, responds with a CTS (clear-to-send) and the data is transmitted. RTS and CTS signals are transmitted over two dedicated wires as defined in the RS-232 standard. Used only with RS-232. Point-to-Point with RTS/CTS (request-to-send/clear-to-send) is a simple hardware handshake protocol that allows an HS-1 to initiate data transfers to the host. <K140,1>
Bar Code Configuration Mode HS-1 Handheld Scanner User’s Manual
Point-to-Point with RTS/CTS
Save Settings 3-9
Page 45
Keyboard Mapping
Keyboard Mapping Usage: Serial Cmd: Default: Options:
Allows the user to determine the language layout of the keyboard. <K116,keyboard mapping,caps lock mode,numeric key> English (U.S.) 0 = English (U.S.) 1 = English (UK) 2 = German 3 = French 4 = Japanese 5 = Spanish 6 = Italian 7 = Universal 8 = Swiss 9 = Czech
U.S. English (Default)
UK English
German
French
Japanese
Spanish
Italian
Universal
Swiss
Czech
Bar Code Configuration Mode
3-10
Save Settings
HS-1 Handheld Scanner User’s Manual
Page 46
Communications
Caps Lock Mode Usage: Serial Cmd: Default: Options:
Allows the user to turn Caps Lock on or off. <K116,keyboard mapping,caps lock mode,numeric key> Off 0 = Off 1 = On 2 = Free
Bar Code Configuration Mode
Off (Default)
On
Free
Save Settings
HS-1 Handheld Scanner User’s Manual
3-11
Page 47
Keyboard Mapping
Numeric Key Usage: Serial Cmd: Default: Options:
Allows the user to select numeric or alphanumeric characters. <K116,keyboard mapping,caps lock mode,numeric key> Alphanumeric Key 0 = Numeric Key 1 = Alphanumeric Key
Bar Code Configuration Mode
Numeric
Alphanumeric (Default)
Save Settings
3-12
HS-1 Handheld Scanner User’s Manual
Page 48
Communications
Preamble Preamble Status Usage: Definition: Serial Cmd: Default: Options:
Useful for identifying and controlling incoming data. For example, defining the preamble as a carriage return and a line feed causes each decoded message to be displayed on its own line. Defines a one to four character data string that can be added to the beginning of the decoded data. <K141,status,preamble character(s)> Disabled 0 = Disabled 1 = Enabled (within any protocol)
Bar Code Configuration Mode
Disabled (Default)
Enabled
Save Settings
Preamble Characters Serial Cmd: Default: Options:
<K141,status,preamble character(s)> ^M (carriage return) To enter control characters within a serial command, hold down the Ctrl key while typing the desired character. Example: <K141,1,CTRL-m> to enter the control character ^M.
Bar Code Configuration Mode
Carriage Return (Default)
Save Settings HS-1 Handheld Scanner User’s Manual
3-13
Page 49
Postamble
Postamble Postamble Status Usage: Definition: Serial Cmd: Default: Options:
Useful for identifying and controlling incoming data. For example, defining the postamble as a carriage return and a line feed causes each decoded message to be displayed on its own line. Allows the user to enable or disable up to four postamble characters that can be added to the end of the decoded data. <K142,status,postamble character(s)> Enabled 0 = Disabled 1 = Enabled (within any protocol)
Bar Code Configuration Mode
Disabled
Enabled (Default)
Save Settings
Postamble Characters Serial Cmd: Default: Options:
<K142,status,postamble character(s)> ^M^J (carriage return/line feed) To enter control characters within a serial command, hold down the Ctrl key while typing the desired character. Example: <K142,1,CTRL-m CTRL-j> to enter ^M^J.
Bar Code Configuration Mode
Carriage Return Line Feed (Default)
Save Settings 3-14
HS-1 Handheld Scanner User’s Manual
Page 50
4 Read Cycle Contents Read Cycle by ESP ...................................................................................................................... 4-2 Read Cycle Serial Commands...................................................................................................... 4-3 Trigger Mode ................................................................................................................................ 4-4 Hand Presentation Timing ............................................................................................................ 4-5 No Read Message ........................................................................................................................ 4-6 Beeper Volume ............................................................................................................................. 4-7
After you’ve established communications you will need to address the timing and output parameters associated with your application. This section explains those parameters.
HS-1 Handheld Scanner User’s Manual
4-1