The text of a manual · part 10 of 15
HS-1 Handheld Scanner User Manual, pages 91 to 100
Pages 91 to 100 of 145
The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan HS-1
Page 91
Plessey Code
Plessey Code Status (Plessey Code) Usage: Definition: Serial Cmd: Default: Options:
Used primarily in library and retail applications. Plessey Code consists of pairs of wide and narrow bars representing binary data which, taken in units of 12, define hexadecimal characters. <K487,status,check character output status,0,minimum symbol length> Disabled 0 = Disabled 1 = Enabled
Bar Code Configuration Mode
Disabled (Default)
Enabled
Save Settings
5-34
HS-1 Handheld Scanner User’s Manual
Page 92
Symbologies
Check Character Output Status (Plessey Code) Definition: Serial Cmd: Default: Options:
When this field is enabled, the check character will be output with symbol data. When disabled, the check character will not be output with symbol data. <K487,status,check character output status,0,minimum symbol length> Disabled 0 = Disabled 1 = Enabled
Bar Code Configuration Mode
Disabled (Default)
Enabled
Save Settings
HS-1 Handheld Scanner User’s Manual
5-35
Page 93
Plessey Code
Minimum Symbol Length (Plessey Code) Definition: Serial Cmd: Default: Options:
This field specifies the minimum number of characters the HS-1 will recognize, including a check character. <K487,status,check character output status,0,minimum symbol length> 0 0 to 32
Bar Code Configuration Mode
5-36
0 (Default)
Save Settings
HS-1 Handheld Scanner User’s Manual
Page 94
Symbologies
Industrial 2 of 5 Status (Industrial 2 of 5) Usage: Definition:
Serial Cmd: Default: Options:
Used primarily in warehouse sortation, photo finishing, and the sequential numbering of airline tickets. Microscan recommends that Industrial 2 of 5 always be used with fixed symbol length settings in any application. Symbol Length # 1 and Symbol Length # 2 can both be set to 0 to allow the HS-1 to decode Industrial 2 of 5 symbols of varying lengths. <K488,status,check character status,check character output status,format, symbol length #1,symbol length #2> Disabled 0 = Disabled 1 = Enabled
Bar Code Configuration Mode
Disabled (Default)
Enabled
Save Settings
HS-1 Handheld Scanner User’s Manual
5-37
Page 95
Industrial 2 of 5
Check Character Status (Industrial 2 of 5) Definition: Serial Cmd: Default: Options:
When this field is enabled, a check character is added. <K488,status,check character status,check character output status,format, symbol length #1,symbol length #2> Disabled 0 = Disabled 1 = Enabled
Bar Code Configuration Mode
Disabled (Default)
Enabled
Save Settings
5-38
HS-1 Handheld Scanner User’s Manual
Page 96
Symbologies
Check Character Output Status (Industrial 2 of 5) Definition: Serial Cmd: Default: Options:
When this field is enabled, the check character will be output with symbol data. When disabled, the check character will not be output with symbol data. <K488,status,check character status,check character output status,format, symbol length #1,symbol length #2> Disabled 0 = Disabled 1 = Enabled
Bar Code Configuration Mode
Disabled (Default)
Enabled
Save Settings
HS-1 Handheld Scanner User’s Manual
5-39
Page 97
Industrial 2 of 5
Format (Industrial 2 of 5) Definition: Serial Cmd: Default Options:
Defines the number of start and stop check characters. <K488,status,check character status,check character output status,format, symbol length #1,symbol length #2> 3 start / 3 stop 0 = 3 start / 3 stop 1 = 2 start / 2 stop
Bar Code Configuration Mode
3 start / 3 stop (Default)
2 start / 2 stop (Default)
Save Settings
5-40
HS-1 Handheld Scanner User’s Manual
Page 98
Symbologies
Symbol Length # 1 (Industrial 2 of 5) Definition:
Serial Cmd: Default: Options:
This field specifies the number of characters that the HS-1 will recognize, including start and stop characters and check characters. The HS-1 ignores any symbol with fewer than the specified number of characters. Because Industrial 2 of 5 is a continuous symbology, it is prone to substitution errors. Therefore, a symbol length must be defined and a symbol must contain an even number of characters. <K488,status,check character status,check character output status,format, symbol length #1,symbol length #2> 10 0 to 32
Bar Code Configuration Mode
10 (Default)
Save Settings
Symbol Length # 2 (Industrial 2 of 5) Definition:
Serial Cmd: Default: Options:
This field specifies the number of characters that the HS-1 will recognize, including start and stop characters and check characters. The HS-1 ignores any symbol with fewer than the specified number of characters. Because Industrial 2 of 5 is a continuous symbology, it is prone to substitution errors. Therefore, a symbol length must be defined and a symbol must contain an even number of characters. <K488,status,check character status,check character output status,format, symbol length #1,symbol length #2> 6 0 to 32
Bar Code Configuration Mode
HS-1 Handheld Scanner User’s Manual
6 (Default)
Save Settings
5-41
Page 99
Industrial 2 of 5
Range Modes (Industrial 2 of 5) Variable Length To set for any length, Symbol Length # 1 and Symbol Length # 2 must both equal zero.
Minimum Length To set for minimum length, both Symbol Length # 1 and Symbol Length # 2 must be equal to each other and be any number other than zero.
Fixed Length To set for a fixed length, Symbol Length #1 and Symbol Length #2 must not be equal to each other.
5-42
HS-1 Handheld Scanner User’s Manual
Page 100
Symbologies
UPC/EAN UPC-A Status (UPC/EAN) Usage: Definition:
Serial Cmd: Default: Options:
Used primarily in point-of-sale applications in the retail industry. UPC (Universal Product Code) is a minimum length, numeric, continuous symbology. UPC can have two- or five-digit supplemental bar code data following the normal code. The UPC Version A (UPC-A) symbol is used to encode a 12-digit number. The first digit is the number system character, the next five are the manufacturer number, the next five are the product number, and the last digit is the checksum character. EAN is the European version of the UPC symbology and is used in European market applications. When enabled, the HS-1 will read UPC-A symbols. <K489,UPC-A status,UPC-E status,EAN-8 status,EAN-13 status,supplementals required,supplemental 2 status,supplemental 5 status,UPC-A as EAN-13, UPC-E as UPC-A,EAN-8 as EAN-13> Enabled 0 = Disabled 1 = Enabled
Bar Code Configuration Mode
Disabled
Enabled (Default)
Save Settings
HS-1 Handheld Scanner User’s Manual
5-43