Page 121
Terminal Window Menus
Terminal Window Menus Right-click on the Terminal window to display the following menu: • Copy selected text to clipboard. • Paste from Terminal or other text. • Clear all text in Terminal window. • Select All text in the Terminal window. • Save... brings up a Save As dialog. • Change Font... of text in Terminal; brings up a Font dialog. • Change Echo Font... to change typed text; brings up a Font dialog. • Enable Echo enables Echo text (typed by user). • Change Background Color of Terminal window. • Non-Printable Characters allows you to hide non-printable characters, or to show them in Standard or Enhanced format. • Default Settings returns all of the above settings to default. • Keyboard Macros allows you to create new keyboard macro commands that can be sent from function keys (F2, F4, F5, etc.)
Terminal Dropdown Menu The dropdown Terminal menu has Capture Text, Save Current Text, Send File, Find Next, and Find Previous functions, as well as the same functions defined above. • Capture Text... lets you append data in real time to a text file of your choice. While in operation, the text file cannot be opened. You can select Pause to interrupt the capture flow or Stop to end the flow and open the file. • Save Current Text... saves all text in the Terminal window to a text file. • Find Next searches for a user-defined section of text in the Terminal. • Find Previous operates in the same way as Find Next, but searches backward through Terminal text.
6-6
HS-1 Handheld Scanner User’s Manual
Page 122
7 Utilities Contents Serial Utility Commands ............................................................................................................... 7-2 Differences from Default............................................................................................................... 7-3 Firmware....................................................................................................................................... 7-4 Default/Reset/Save....................................................................................................................... 7-5 Scanner Status Request............................................................................................................... 7-6 Bar Code Configuration Mode ...................................................................................................... 7-7
Utility commands are generally commands that can be sent during HS-1 operations to perform miscellaneous operations on HS-1 hardware. Serial utility commands are not prefaced with a ”K” and a numeric value, nor do they require an initialization command (<A> and <Z>). They can be entered from ESP’s Terminal or Utilities views.
HS-1 Handheld Scanner User’s Manual
7-1
Page 123
Serial Utility Commands
Serial Utility Commands Note: For a list of all K commands, see Serial Configuration Commands on page A-8. Type Part Number
Command <#> <H> <I> <A> <Z>
Device Control
Default/Reset/Save
<Zrd> Scanner Status Request Trigger
<K?> <char>
Name Display Firmware Part Number Enable Scanner Disable Scanner (Continuous, external trigger) Reset (does not save for power-on) Save Current Settings for Power-On Recall Microscan Default Parameters and Save for Power-On Configuration Command Status Serial Trigger Character
Bar Code Utility Commands
Bar Code Configuration Mode
Reset (Does Not Save for Power-On)
7-2
Save Current Settings for Power-On
Recall Microscan Default Parameters and Save for Power-On
HS-1 Handheld Scanner User’s Manual
Page 124
Utilities
Differences from Default Clicking the Differences from Default button will cause ESP to check all stored configuration settings and compare them to default settings. All settings that are different than default will appear in the left column (shown below), and descriptions of those settings will appear in the right column. Click this button for a list of ESP configuration settings that are different than default settings.
Send configuration settings to the HS-1 without saving by clicking Send to Reader.
Click Save As to save the report as plain text or a tab-delimited text file.
Send configuration settings to the HS-1 and save in ESP by clicking Send and Save.
• To save the Differences from Default report, either as plain text or as a tab-delimited text file, click Save As. • Click Send and Save to send the settings to the HS-1 and save them, or Send to Reader to send the settings without saving them. Important: The use the Differences from Default feature, you must connect to the HS-1 and Receive Reader Settings via the Send/Recv button on the toolbar.
HS-1 Handheld Scanner User’s Manual
7-3
Page 125
Firmware
Firmware Firmware Verification ESP allows you to send a request to the HS-1 for the application code part number. • Click the Firmware tab. • Click the Request Part No. button. • The application code part number will be displayed in the text field to the right of the Request Part No. button.
7-4
HS-1 Handheld Scanner User’s Manual
Page 126
Utilities
Default/Reset/Save Understanding and controlling your HS-1’s active, saved, and default settings is critical to its successful operation. Serial Cmd
ESP (first, right-click in any menu tree)a
Reset
<A>
Save to Reader, Send No Save
Save Current Settings for Power-On
<Z>
Save to Reader, Send and Save
Recall Microscan Default Parameters and Save for Power-On
<Zrd>
No
Save for Power-on
Reset (not saved for power-on)
Function a. When you right-click in a menu tree and select Default Current Menu Settings or Default All ESP Settings, it is important to note that only ESP settings are defaulted. To save these defaults to the HS-1 itself, you need to follow up with a Save to Reader, Send and Save command.
Reset Reset (“A” command) affects only current settings (active memory) and does not save for power-on.
Save for Power-On Power-on parameters (“Z” commands) are saved, recalled, and loaded into current parameters when power is cycled to the HS-1. Important: The following commands must be followed by a <Z> to be saved for power-on: Host Protocol, Baud Rate, Data Bits, Stop Bits, Parity, Trigger Characters (Delimited, Start, Stop), Preamble, Postamble, and No Read Message. All other parameters are saved for power-on without a <Z>. However, a <Zrd> affects all parameters.
HS-1 Handheld Scanner User’s Manual
7-5
Page 127
Scanner Status Request
Scanner Status Request <K?> Configuration Command Status This is the fastest way to learn the HS-1’s current configuration. Sending this request will return the current settings of all commands, starting with the lowest K command value and ending with the highest K command value.
7-6
HS-1 Handheld Scanner User’s Manual
Page 128
Utilities
Bar Code Configuration Mode Bar Code Configuration Mode is enabled when the scanner decodes the following symbol:
After reading this symbol, the scanner remains in Bar Code Configuration Mode until it decodes a symbol containing the <A>, <Z>, or <Zrd> (Reset, Save Current Settings for Power-On, or Recall Microscan Default Parameters and Save for Power-On) command, or receives one of these commands from the communication port. While in Bar Code Configuration Mode, the reader decodes symbols and processes the symbol data as if they were serial commands. Configuration symbols can be created in ESP, using the Bar Code Dialog.
HS-1 Handheld Scanner User’s Manual
7-7
Page 129
Bar Code Configuration Mode
7-8
HS-1 Handheld Scanner User’s Manual
Page 130
Appendices Contents Appendix A General Specifications .............................................................................................. A-2 Appendix B Electrical Specifications ............................................................................................ A-5 Appendix C Serial Configuration Commands............................................................................... A-8 Appendix D Communications Protocol....................................................................................... A-11 Appendix E ASCII Table............................................................................................................. A-12 Appendix F Glossary of Terms................................................................................................... A-13