Page 131
General Specifications
Appendix A, General Specifications Mechanical Height: 6.3” (160 mm) Width: 2.8” (68 mm) Depth: 3.5” (88 mm) Weight: 7.8 oz. (220 g) including cable
Environmental Operating Tempurature: 0° to 50° C (32° to 122° F) Storage Tempurature: –20° to 60° C (–4° to 140° F) Humidity: 20% to 85% (non-condensing) Shock: Withstands drops of 6’ (1.8 meters) to concrete
Symbologies UPC/EAN, Code 39, Code 128/EAN-128, Interleaved 2 of 5, Industrial 2 of 5, Codabar, Code 93, MSI Code, Plessey Code, China Postal Code, GS1 DataBar, PDF417
Light Collection Options Sensor: 2,048 pixel CCD image sensor Optics: 660 nm visible LED
Communications Standard Interface: USB, RS-232
Read Parameters Decode Rate: 230 decodes/second Depth of Field: 2.8 to 3.5” (70 to 90 mm) Ambient Light Immunity: Sunlight: up to 278 ft. candles (3,000 lux)
Indicators Status Indicators: Audible tones, visible feedback with multi-color LED
Electrical Power: 5VDC Typical: 240mA Peak: 750mA Idle: 95mA
HS-1 Dimensions
A-2
HS-1 Handheld Scanner User’s Manual
Page 132
Appendices Read Ranges
Narrow Bar Width 3 mil (0.076 mm) 4 mil (0.102 mm) 5 mil (0.127 mm) 15.6 mil (0.396 mm)
Read Range Distance 2.28 to 2.87” (58 to 73 mm) 2.17 to 3.35” (55 to 85 mm) 1.77 to 4.33” (45 to 110 mm) 1.18 to 8.66” (30 to 220 mm)
Note: All read range values based on a Grade A Code 39 symbols except the 15.6 mil read range value, which is based on a Grade A EAN 128 symbol.
HS-1 Handheld Scanner User’s Manual
A-3
Page 133
General Specifications Safety Certifications FCC, CE, RoHS/WEEE
ISO 9001 Registered Company
©2010 Microscan Systems, Inc. All rights reserved. Specifications subject to change. Product specifications are given for typical performance at 25°C (77°F) using grade A labels. Performance characteristics may vary at high temperatures or other environmental extremes. Warranty–One year limited warranty on parts and labor. Extended warranty available.
A-4
HS-1 Handheld Scanner User’s Manual
Page 134
Appendices
Appendix B, Electrical Specifications Power: 5VDC Typical: 240mA Peak: 750mA Idle: 95mA
USB Cable Pinouts
HS-1 Handheld Scanner User’s Manual
A-5
Page 135
Electrical Specifications
USB Virtual Comm Cable Pinouts
A-6
P4
Pi
USB CONNECTOR
¢ MALE > wise euNeneN ov FUNCTION RF45 10PIN (MALE) ‘ GNo, BLACK vec oi pecei, GREL sé e eo BROWN 3 D+ a e+ - _ PC- DATA, - - - 5 ; GND ~ _ + KB - DATA SLE 9 & @} - - voc, fEO
~I
HS-1 Handheld Scanner User’s Manual
Page 136
RS-232 Cable Pinouts
Appendices
3e Se eal wn LeRARA AB |p SIDE 1 2 DC - JACK i 9PIN D-SUB eat [| (FEMALE) ae 10 9PIN (F) FUNCTION RJ 45 NC reo)" SS 5 - - - GND iments: il 3(RXD), - - PC- - DATA - - - - 5 2(TxD), - - PC-CLK, - 6 NC i ee ca Wiis), - - KpeCLK 8 8(RTS), - - KB -DATA 9g SHELL SHIELD NC HS-1 Handheld Scanner User’s Manual A-7
Page 137
Serial Configuration Commands
Appendix C, Serial Configuration Commands Note: For a list of utility commands such as read rate requests, device control options, and scanner status requests, see Serial Utility Commands on page 7-2. Communications Host Port Connections Keyboard Mapping Communications Mode Host Port Protocol Preamble Postamble Read Cycle Trigger Mode Hand Presentation Timing No Read Message Beeper Volume Symbologies Code 128/EAN 128 Code 39 Codabar Interleaved 2 of 5 Code 93 PDF417 DataBar Omnidirectional (RSS-14) DataBar Limited (RSS Limited) DataBar Expanded (RSS Expanded) MSI Code Plessey Code Industrial 2 of 5 UPC/EAN China Postal Code Symbology Identifier
A-8
<K100,baud rate,parity,stop bits,data bits> <K116,keyboard mapping,caps lock mode,numeric key> <K117,communications mode> <K140,protocol> <K141,status,preamble characters> <K142,status,postamble characters> <K203,trigger mode> <K205,time between identical decodes> <K714,status,No Read message> <K752,beeper mode> <K464,status,0,minimum symbol length,1,1,0,application record separator character> <K470,status,check character status,check character output status, 0,0,minimum symbol length,full ASCII set> <K471,status,0,start/stop match output status,0,symbol length status, symbol length,check character status,check character output status> <K472,status,check character status,check character output status, symbol length #1,symbol length #2,guard bar,range mode status> <K475,status,0,minimum symbol length> <K476,status> <K482,status> <K483,status> <K484,status> <K486,status,check character mode,check character output status, 0,minimum symbol length> <K487,status,check character output status,0,minimum symbol length> <K488,status,check character status,check character output status, format,symbol length #1,symbol length #2> <K489,UPC-A status,UPC-E status,EAN-8 status,EAN-13 status, supplementals required,supplemental 2 status,supplemental 5 status,UPC-A as EAN-13,UPC-E as UPC-A,EAN-8 as EAN-13> <K498,status,check digit mode,min length,max length> <K753,0,symbology identifier status>
HS-1 Handheld Scanner User’s Manual
Page 138
Appendices
Serial Command Format Serial commands are of two types: utility and configuration.
Rules that apply to both utility and configuration commands • A less than < and greater than > character enclose the commands. • Commands and data are “case sensitive.” That is, characters must be entered as upper or lower case, as specified.
Serial Utility Commands These are sent during operations and are not followed by <A> or <Z>.
Serial Configuration “K” Commands These begin with a single “K” character followed by a 3-digit numeric character, data fields, and an initializing command, as follows: <Knumeric parameter,data,data,...etc.><initializing command> An initializing command <A> or <Z> may follow the command. A <Z> initializes the HS-1’s memory and saves for power-on; an <A> initializes the HS-1’s memory but does not save for power-on. For example, to enable UPC and save the change for power-on, send <K473,1><Z>. To change Baud Rate and reset without saving changes for power-on, send <K100,3><A>.
Serial Configuration Command Conventions • All data fields (except the last) must be followed by a comma (without a space). • NUL cannot be used. The characters <, >, and , can be used, but only if entered as hex pairs. • All fields preceding a modified field must be included. • If there is no change in preceding fields, then commas alone can be entered in these fields. For example, if only the last field in the following command is changing, <K100,4,1,0,0> can be entered as <K100,,,,0>. • All fields following a modified field can be omitted. For example, to change Baud Rate only, send <K100,3>.
HS-1 Handheld Scanner User’s Manual
A-9
Page 139
Communication Protocol Commands
Concatenating Configuration Commands Commands can be concatenated (added together) in a single string or data block. For example, <K145,1><K220,1><K450,1><A> enables LRC, sets End of Read Cycle mode to New Trigger, enables Narrow Margins, and resets the data buffers (without saving the changes for power-on).
Serial Command Status Request To ensure that any command was received and accepted, you can send the Show Scanner Status command: <?>. The status of a specific serial command can be requested by entering the command followed by a question mark. For example, send <K142?> to request the status of Postamble.
Entering Control Characters in Serial Commands To enter control characters within a serial command, hold down the Ctrl key while typing the desired character. Example: To enter a carriage return and line feed (^M^J), enter <K141,1,CNTL-m CNTL-j>
A-10
HS-1 Handheld Scanner User’s Manual
Page 140
Appendices
Appendix D, Communications Protocol Communications Protocol Command Table Protocol Command (Mnemonic displayed on menu)
Control Characters (Entered in menu or serial command)
Hex Value
Effect of Command
RES
^D
04
Reset
REQ
^E
05
Request
EOT
^D
04
Reset
STX
^B
02
Start of Text
ETX
^C
03
End of Text
ACK
^F
06
Acknowledge
NAK
^U
15
Negative Acknowledge
XON
^Q
11
Begin Transmission
XOFF
^S
13
Stop Transmission
HS-1 Handheld Scanner User’s Manual
A-11