The text of a manual · part 28 of 34
HawkEye 1500 Series User Manual, pages 271 to 280
Pages 271 to 280 of 338
The original document is the PDF (3.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan HE1510, RVSI CiMatrix HE1510 and Siemens HE1510
Page 271
Do not exceed 0.5 amp continuous current draw or you may damage the HawkEye™ 1500.
Lighting Connector For complete information about the Light Port Connector, see “Light Port Connector” on page 2-45.
v2.4.1, Nov 2008
HawkEye™ 1500 Series User Manual
A HawkEye™ 1510
Lighting Connector
A-7
Page 272
Appendix
A-8
A
HawkEye™ 1510
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008
Page 273
B Troubleshooting & Frequently Asked Questions
APPENDIX B
This appendix contains troubleshooting tips and answers to frequently asked questions for the HawkEye™ 1500 Series Smart Camera-Based Reader.
Frequently Asked Questions My camera is connected to the network and serial port, but I have no idea what the current communication settings are. How do I figure it out? The HawkEye™ 1500 can communicate via the serial port or over Ethernet to ReadRunner. First, try using ReadRunner and add a button for either COM1 or COM2, depending on the serial port on your PC you have connected to the camera. Once connected, ReadRunner hooks reports and/or images from the camera on a timed basis. This data is transferred via Xmodem protocol. If you can connect via the serial port, click Settings>Serial/TCP Settings… and examine the network and serial port configuration. If ReadRunner does not connect with the serial port, try using HyperTerminal (provided by the operating system). Run HyperTerminal and create a connection on your serial port with the following settings: • v2.4.1, Nov 2008
Baud rate, 115200
HawkEye™ 1500 Series User Manual
B-1
Troubleshooting & Frequently Asked
B
Page 274
Appendix
B
Troubleshooting & Frequently Asked Questions
•
Parity, N
•
Data bits, 8
•
Stop bits, 1
•
Flow control, None
These are the default camera settings. Connect to the camera and see if you get any text. If nothing comes out, press Ctrl+T. This control character causes the camera to dump an information string. If you don’t get a string, then your serial port parameters do not match the camera. You must try different settings until they match and you get characters from the camera. If you get a string that looks like “->”, type in: cmd “console 0” and reboot the unit. Reconnect to the camera and verify that result strings are properly received and displayed. Once you get a set of serial parameters that work, you can use a series of commands to determine the camera configuration. In HyperTerminal, press Ctrl+S to take control of the unit and take it offline. Then, press Ctrl+P to get a prompt and activate terminal echo over the serial port. The following commands tell you how the camera is configured: IPCONFIG ?, Displays the name of the camera and its current IP address DHCP ?, Returns Y (if DHCP is on) or N (if DHCP is off) You can use this information to verify the network configuration. Use the IP command to change the name of the camera and the address you want to use when DHCP addressing is disabled.
I have DHCP activated, but the camera reports a 169.254.x.x address. What’s happening? If your HawkEye™ 1500 is programmed for DHCP addressing and there is no DHCP available, the HawkEye™ 1500 defaults to a class B address in the 169.254.x.x subnet. This is similar to how Windows 2000 and XP function. It also allows you to connect a Windows 2000 PC and HawkEye™ 1500 with a cross-link Ethernet cable and leave DHCP addressing activated, but still communicate. Both sides of the connection pick a different 169.254.x.x address and should communicate normally.
B-2
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008
Page 275
Frequently Asked Questions
Your PC and camera must be operating on the same subnet. The “Subnet Mask” determines the base address of the subnet. Typically, the subnet is either 255.255.0.0 (Class B) or 255.255.255.0 (Class C). For Class B, this means the first two numbers of the address define the subnet and the last two can be any numbers from 1 to 255 each. For Class C, this means the first 3 numbers define the subnet and the last number can be any number from 1 to 255. You can determine your PC’s network configuration from a Command Prompt by running “ipconfig /all”. This utility displays each network entity and all its details. Ensure that the PC and the camera have identical subnets and valid IP addresses.
How do I restore the camera to factory defaults? ReadRunner allows you to restore the decoder and/or application mode settings to factory defaults. Some settings are persistent still (speaker on/off, communication settings, etc.), so, to truly restore all settings to factory defaults, use the RESET ALL command and reboot the camera. This restores all decoder settings, application mode settings, and communication settings to the defaults. The camera’s name changes back to “HawkEyexxyyzz” (where xxyyzz is the last three octets of the camera’s MAC address), and DHCP is activated.
When should I use DHCP? DHCP is a useful protocol for dynamically addressing client computers using TCP/IP. However, there are some warnings as well. DHCP usually requires clients to “renew” addresses over a period of time. This can cause client addresses to change at any time, depending on how your network is configured. The problem is, if you are receiving data from your HawkEye™ 1500 over TCP/IP and the Ethernet address of either the PC or the camera changes, you will lose connectivity to the camera and need to re-establish it. This can mean loss of data to the client. If your application requires that you cannot lose data, do not use DHCP. Work with your IT department to statically assign addresses to both the PC and the HawkEye™ 1500 so they do not change addresses.
v2.4.1, Nov 2008
HawkEye™ 1500 Series User Manual
B-3
B Troubleshooting & Frequently Asked
How can I tell if the IP configuration of my PC and my camera are valid?
Page 276
Appendix
B
Troubleshooting & Frequently Asked Questions
I have no idea what the current settings are for the camera. What do I do? Should you encounter a situation where you have no idea what the current settings on the camera are, you can reset the camera to its factory defaults and resume from there. To restore the factory default settings to the camera, press Ctrl+Z, or select Restore Factory Defaults from the ReadRunner File menu. Click Yes when asked if you wish to control camera X. ReadRunner displays the message: Camera settings are restored to defaults The HawkEye™ 1500 camera also beeps once.
What if Learn succeeds but read fails? When Learn or Assisted Learn is successful, the Pixels Per Cell should ideally be set to the average cell size in pixels. This value can be estimated by dividing the Matrix Height by the Number of Matrix Rows. If this value is far greater than the default value of 6, then it can increase the decode time significantly. An attempt to optimize the HawkEye™ 1500 for speed for a variety of applications is to always set the Pixels Per Cell to 6 regardless of the actual value. In rare situations, this optimization can have negative impact on the robustness. Therefore, if an image fails to read when Learn is successful, try to increase or decrease the Pixels Per Cell gradually until the image is decoded.
My decode data is very long. Is there a way to disable the sending of this data on the serial port? If your data is very long, it may take a long time to report this data on the serial port. If you are not using the serial port at all, you can gain this time back for processing. You can disable the serial port connectivity by using the CONSOLE command. The CONSOLE command directs the camera to connect its operating system debugging console to a particular serial port. The serial port surfaced on the camera is port 2, so use the command “CONSOLE 2” to redirect the debugging console accordingly. Once the debugging console is set, result data will no longer be sent to the serial port.
B-4
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008
Page 277
Frequently Asked Questions
A connection has taken control of my camera and I can’t regain control. Is there a way to break this control so I can get it back? Yes. You have three options: 1.
Reboot the camera.
2.
Connect your serial cable to the camera, open HyperTerminal, and connect to the camera. Press Ctrl+S to forcibly take control of the camera and take it offline. You should see an information string with details about the name of the camera, current counts, software version, etc., when this happens. Press Ctrl+R to release control and put it back online.
3.
If the camera is under control via an Ethernet connection, disconnect the Ethernet cable from the camera. Wait a few seconds and plug it back in. Any Ethernet connections are cleared and you should be able to reconnect to the camera and regain control.
When I disconnect the network cable from the PC while the camera is under control by ReadRunner, reconnecting the network cable will not allow ReadRunner to take control again. What do I do? ReadRunner cannot regain control of the camera because control was not properly released when the network cable was disconnected from the PC. Use option 3 in the previous FAQ to regain control of the camera.
I had control of the camera over the serial port and left the machine for a few minutes. When I came back, the camera was no longer under control. What happened? When you have control of the camera over the serial port, control is maintained as long as there is input activity on the serial port. If there is no activity for 2 minutes, then the camera is released and put back online (if it was offline). To v2.4.1, Nov 2008
HawkEye™ 1500 Series User Manual
B-5
B Troubleshooting & Frequently Asked
Note: Once this option is set, your camera is unusable over the serial port. To restore the camera’s normal serial port connectivity, issue the command “CONSOLE 0” from the Terminal window in ReadRunner.
Page 278
Appendix
B
Troubleshooting & Frequently Asked Questions override this timeout, take control of the camera and type Ctrl+S a second time. The timeout is now disabled until you release control again. You can use the ONLINE command (see the HawkEye™ 1500 Series Reference and Programmer Manual) to put the unit back online and maintain control.
I’m using the Part Queue to record images on the camera but, after a while, the camera runs much slower. What’s going on? The Part Queue mechanism of the camera can store, typically, up to 30 sets of images and results in a ring buffer. This can consume most of the camera memory and can fragment memory. Memory will be fragmented whenever the Part Queue is cleared, and the queue is cleared either when the images are uploaded or cleared in QueueView. From QueueView, you can also upload the records without clearing the Queue. To avoid this memory fragmentation, upload the Queue without clearing it; the Queue will continue to reuse its records and performance will not be impacted.
Do the version numbers have to match? Yes. For proper operation, the version of the software displayed in the Network Overview Window must match the ReadRunner revision used to connect to the camera. Starting with V2.0, ReadRunner is now capable of communicating and controlling V1.0 and V1.1 camera software.
What’s the timing for normal strobe and power strobe? I’m assuming that both strobe modes would go off immediately after the trigger (or the configured delay) and then stay on for some fixed duration? Is that correct? What's the duration? Is the duration different for each strobe mode? The timing is identical for the Strobe and Power Strobe. The difference is the light intensity output. In Power Strobe, the LEDs are overdriven, and therefore brighter. The duration is controlled by the Exposure setting and is limited to a maximum of 1 msec for Power Strobe as opposed to 20 msec for Strobe.
B-6
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008
Page 279
Frequently Asked Questions
Yes, it is an electronic shutter internal to the CCD. It can be set between 30 usec and 20000 usec. It is the time during which light is integrated by the CCD sensor and also the time the light remains ON when in Strobe or Power Strobe. When using an external fast Xenon strobe, then the duration of the strobe pulse is no longer controlled by the camera and the exposure acts as an electronic shutter as opposed to also controlling the duration of the light remaining on. This allows for shorter light pulses than 30 usec for very fast motion applications.
What exactly happens with auto photometry when using a sensor as a trigger? The HawkEye™ has only one chance to get an image, so I can only imagine that the settings are adjusted after each image, hoping that the adjustment will be appropriate for the next part. Am I correct? In Motion mode, the Auto Photometry is turned off, as this requires up to 5 “small” pictures, which take about 10 msec each. By the time the Exposure and Gain are figured out, the part would have moved out of the field of view. In this mode, Manual Photometry should be used. In Stop and Scan mode, Auto Photometry can be used.
I’m trying to re-install all my computer software after it was attacked by a virus. When I run the ReadRunner install, neither the “Repair” option nor the “Remove” option seems to do anything. How can I re-install ReadRunner once this happens? ReadRunner uses InstallShield as its install engine. All InstallShield installation projects use an identifier (or GUID) to identify whether or not the software is installed on the system. When the installation is run and the GUID is detected, you get the “Repair/Remove” dialog that lets you re-run the install with everything that was selected, or remove the software. However, if a virus has wiped out some of this information, you may not be able to re-install. To forcibly re-install, find the hidden folder “Installshield Installation Information” under C:\Program Files and delete the folder: {2D1FFA0F-F587-11D6-8110-00C04F606F20} v2.4.1, Nov 2008
HawkEye™ 1500 Series User Manual
B-7
B Troubleshooting & Frequently Asked
Is the “Exposure” in the Photometry dialog and command the same as the “Shutter” on the HawkEye™ 15?
Page 280
Appendix
B
Troubleshooting & Frequently Asked Questions
The next time you run the install, it will operate as if the software is installing for the first time.
Sometimes, when using a Logitech mouse and scrolling with the wheel, I see crashes in ReadRunner especially in the Network Overview form. What can I do to fix this behavior? This occurs with older Logitech mouse drivers when trying to scroll the Microsoft FlexGrid control with the wheel. Updating to the latest Logitech drivers will fix this problem available on the Logitech website.
Trouble Reading Setting the HawkEye™ 1500 to Factory Default Settings If you have problems reading or decoding a symbol, it could be because the system is set up with a “learned” Data Matrix. The system may have been configured to read a specific type of symbol; one that does not match the characteristics of the provided symbols (or the one you may have created yourself). If you do not have access to ReadRunner, you can “open up” the decoder to read almost any symbol by depressing the QuicSet button on the back of the camera for 3 to 4 seconds. For more information, see the section titled “QuicSet Decoder Factory Defaults” in the HawkEye™ 1500 Series Quick Start Guide.
Samples of Reader Programming Data Matrices Setting Serial Communications
TTY 2400 N 8 1 N
B-8
TTY 9600 N 8 1 N
TTY 115200 N 8 1 N
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008