Page 281
Trouble Reading
Setting Triggers
B TRIG T
Troubleshooting & Frequently Asked
TRIG C
Resetting
RESET DECODER
RESET APPMODE
RESET FACTORY
Setting Targeting
TARGET OFF
TARGET ON
Setting Beeper
BEEP Y
BEEP N
Setting Illumination
ILLUM OFF
ILLUM ON
ILLUM STROBE
Resetting ROI
ROI RESET v2.4.1, Nov 2008
HawkEye™ 1500 Series User Manual
B-9
Page 282
Appendix
B
Troubleshooting & Frequently Asked Questions
Setting Learn/Unlearn
LEARN
UNLEARN
Setting Photometry
PHOTO MAN
PHOTO AUTO
Saving
SAVE
Setting DHCP
DHCP Y
B-10
DHCP N
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008
Page 283
C Upgrading Camera Software
C Upgrading Camera Software
APPENDIX C
This appendix describes how to upgrade the HawkEye™ 1500 Series Smart Camera-Based Reader’s software using either HawkEye™ Flasher or the HawkEye™ bootloader. Note: In this chapter, we use specific camera and software version numbers as an example. Please use the latest HawkEye™ software available and substitute in your version numbers in the procedures.
Overview The HawkEye™ 1500 uses Flash memory to store a series of binary images that are executed when the camera starts up. These images include:
v2.4.1, Nov 2008
•
Bootloader, Simple menu-driven interface that examines Flash memory and downloads and executes .SEC files (via the serial port).
•
FPGA, Binary image that drives the image acquisition hardware.
•
BootParams, Binary image that sets up networking and other persistent parameters.
•
Registry, Binary image used for all decoder, acquisition, and serial communication parameters.
• vxWorks Kernel, The camera operating system itself.
HawkEye™ 1500 Series User Manual
C-1
Page 284
Appendix
C
Upgrading Camera Software
Caution: While the versions of vxWorks kernel and Bootloader should be kept the same by downloading both, downloading the registry will wipe out customer configurations, and should be used only when this is desired. Typically, when you upgrade the camera’s software, you upgrade only the Bootloader, Registry and vxWorks Kernel, and you use the HawkEye™ Flasher to do so. You can use the Flasher to upgrade your camera over the network or by using the serial port. These files are installed on your hard drive in the “Camera Binaries” folder under ReadRunner (typically, “C:\Program Files\ReadRunner\Camera Binaries”). Use the HawkEye™ Bootloader only when you have no network connection to the camera and your camera fails to start up.
Using HawkEye™ Bootloader The HawkEye™ Bootloader is a simple, menu-driven interface embedded on the camera that examines and updates the camera’s flash memory. When using the bootloader, you transfer .SEC files to the camera via the serial port and execute the files. These .SEC files automatically update the appropriate section of flash memory. Note: All .SEC files were written to flash memory at the Microscan factory when your camera was assembled. There is no specific need to re-write any portions of this flash memory with the bootloader. Use the bootloader to update your camera only when instructed to do so. The .SEC files that created your camera’s software image are installed on your hard drive in the “ReadRunner/Camera Binaries” folder. The .SEC files on the CD include: • bootloader_Reader.sec, Bootloader image
• registry_Reader.sec, Registry image
• vxWorks_Reader.sec, vxWorks kernel image
To run the bootloader:
C-2
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008
Page 285
Using HawkEye™ Bootloader
Power up your camera while pressing in the Quicset button.
2.
Connect the serial cable to the camera and your PC.
3.
Run HyperTerminal by selecting Start>Programs>Accessories.
4.
Connect to the appropriate serial port using the following settings:
5.
–
Baud Rate, 115200
–
Data Bits, 8
–
Parity, N
–
Stop Bits, 1
–
Flow Control, None
C Upgrading Camera Software
1.
Click OK. The following information is displayed: HawkEye BootLoader HE1500 Ver 5.45 (206MHz, 32MB RAM, 4MB Flash) d m dt et dbp mbp dm dfb der wmr wpr cpu flsh ram cach x r j e h >> v2.4.1, Nov 2008
Dump memory Modify memory Display tests Execute test Dump boot params Modify boot params Display menu Dump flash blocks Dump enet regs Write MAC reg Write PHY reg Dump CPU registers Get Flash size Get RAM size I-Cache control File transfer Reset unit Jump to app Display error Help
HawkEye™ 1500 Series User Manual
C-3
Page 286
Appendix
C
Upgrading Camera Software
6.
Press X to download a .SEC file.
7.
Select Send File from the Transfer menu.
8.
Browse for bootloader_Reader.sec on the CD, select Xmodem as the protocol, and then click Send, as shown in Figure C–1.
FIGURE C–1. Send File Window
Xmodem transfers the file to the camera’s memory, as shown in Figure C–2. FIGURE C–2. Xmodem File Send Window
When complete, the bootloader menu is re-displayed. 9.
C-4
When complete, press J to jump to the camera application.
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008
Page 287
Using HawkEye™ Flasher
Using HawkEye™ Flasher The HawkEye™ Flasher is a simple application you use to upgrade your camera’s software. It allows you to select a camera, a Registry file, a Bootloader file, and/or a vxWorks kernel file, then update the camera accordingly. FIGURE C–3. Flasher Window
Upgrading Camera Software
C v2.4.1, Nov 2008
HawkEye™ 1500 Series User Manual
C-5
Page 288
Appendix
C
Upgrading Camera Software
The cameras that are detected on the local network are listed in the “Camera:” box, along with “COM1:” and “COM2:”. You can flash cameras on a separate subnet by selecting <Static IP Address> in the Camera drop down window and typing in the IP address of the camera. Camera devices are automatically added to the list as they are detected on the network. The last camera you selected is automatically selected when detected on the network. All file selections and settings are also restored each time you run Flasher, except for those cameras defined with <Static IP Address>. The files you select with the Flasher are .BIN files; that is, these files are binary executable images readable by the camera. The files are transferred to the camera’s memory and are then moved to the Flash memory. Caution: Before updating your camera’s Registry, be sure to save your camera’s configuration to the hard drive using ReadRunner. Otherwise, the configuration will be lost. The Flasher monitors this entire process. When the process finishes, the Flasher automatically reboots the camera and reports the new software version. The Flasher also supports several command line options: •
“-quit”, When this option is given, the Flasher automatically updates the last camera you selected according to the previous settings.
•
“-doreg”, This option sets the “Load Registry File” option.
•
“-noreg”, This option clears the “Load Registry File” option.
•
“-dokernel”, This option sets the “Load vxWorks Kernel File” option.
•
“-nokernel”, This option clears the “Load vxWorks Kernel File” option.
•
“-dobtl”, This option sets the “Load Bootloader” option.
•
“-nobtl”, This option clears the “Load Bootloader” option.
•
“-cam name”, This option allows you choose the specific camera to update, by name.
Use the following procedure to upgrade the camera using Flasher: 1.
C-6
Select Start, Programs, ReadRunner #.#, Utilities, and HawkEye Flasher. The Flasher window is displayed, as shown in Figure C–3.
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008
Page 289
Using HawkEye™ Flasher
2.
From the Camera pull down menu, select the camera whose software you want to upgrade. Note: You can also select <Static IP Address>. If you do so, the “Enter Camera Static IP Address” dialog box is displayed. Enter a valid IP address and click OK. Select Load Registry File. This is the camera’s system Registry, and is similar to the Window’s Registry.
4.
Click ... and navigate to the Camera Binary folder in the ReadRunner folder. Highlight registry.bin.
5.
Select Load vxWorks Kernel File. This is the camera’s software kernel.
6.
Click ... and navigate to the Camera Binary folder in the ReadRunner folder. Highlight vxWorks.bin.
7.
Select Load Bootloader File. This is the software that boots the camera. Click ... and navigate to the Camera Binary folder in the ReadRunner folder. Highlight bootloader.bin. Note: Always load the version of the Bootloader that corresponds to the version of vxWorks.bin to assure consistency, unless explicitly told not to in the HawkEye™ 1500 Release Notes.
8.
Click Update!
Flasher stores the files in the flash memory of the camera. This process takes about 40 seconds.
v2.4.1, Nov 2008
HawkEye™ 1500 Series User Manual
C-7
Upgrading Camera Software
C
3.
Page 290
Appendix
C-8
C
Upgrading Camera Software
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008