Page 221
Fine Tuning & Monitoring Your Application
Range: 8 - 256 Default: 16 –
Vertical Spacing, This pull down menu specifies the vertical spacing. Range: 8 - 256 Default: 16 Read Timeout, This parameter specifies the time to spend inspecting a symbol. For more complete information, see “Read Timeout” on page 4-52. Range: 0 - 9999ms Default: 600ms
–
Min Barcode Height, This pull down menu specifies the minimum height of the barcode. Range: 4 - 400 Default: 4
–
Max Barcode Height, This pull down menu specifies the maximum height of the barcode. Range: 4 - 400 Default: 400
–
Min Barcode Length, This pull down menu specifies the minimum length of the barcode. Range: 20 - 600 Default: 20
–
Max Barcode Length, This pull down menu specifies the maximum length of the barcode. Range: 20 - 600 Default: 600
– v2.4.1, Nov 2008
Min Barcode Width, This pull down menu specifies the minimum barcode width.
HawkEye™ 1500 Series User Manual
4-111
4 ReadRunner
–
Page 222
Chapter
4
ReadRunner
Range: 1 - 100 Default: 1 –
Max Barcode Width, This pull down menu specifies the maximum barcode width. Range: 1 - 100 Default: 100
–
Min Number of Bars, This pull down menu specifies the minimum number of the bars. Range: 2 - 100 Default: 2
–
Max Number of Bars, This pull down menu specifies the minimum number of the bars. Range: 2 - 100 Default: 100
–
Enable Barcodes, When you click this parameter, ReadRunner displays the Symbology/Verification Window. Select the barcodes you want enabled.
–
Min Quiet Zone Length, The minimum length of the Quiet Zone. If for any reason the quiet zone is less than the default value in the image due to camera setup restrictions, the Min Quiet Zone Length parameter can be decreased in order for the algorithm to accept shorter space as quiet zone. On the other hand, if the barcode is big in the FOV such that some space between two adjacent bars exceeds the value specified in the Min Quiet Zone Length, then there is a possibility that this space will be detected as possible quiet zone. To avoid this situation, the Min Quiet Zone Length can be increased. (Supported with the BARQZ terminal command.) Range: 5 - 100 Default: 12 Note: Do not adjust Min Quiet Zone Length unless you understand how the change will affect the system performance. Since Learn Barcode uses the parameter values specified in above dialog box, setting these values inappropriately may cause the Learn Barcode to fail.
4-112
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008
Page 223
Fine Tuning & Monitoring Your Application
–
Min Threshold, The barcode threshold out of 255 grayscale. (Supported with the BARTHRESH terminal command.) Range: 5 - 100 Default: 18
–
Confidence (0 - 100), For barcodes that do not use checksum such as Code 39, I 2 of 5, Codabar, and BC412, the threshold value can help reduce potential misdecodes. The default value is 0, meaning that any possible decode is accepted. When the value is raised, a certain number of decodes must agree before the decode is declared successful. On the other hand, if the value is set too high, then a normally decodable but imperfect barcode may not be decoded. (Supported with the BARCONF terminal command.)
4
Range: 0 - 100 Default: 0 Probe Direction, Enables you to set the direction of the search: •
HORI
•
VERT
•
HORI_VERT (default)
•
VERT_HORI
ReadRunner
–
(Supported with the BARPRB terminal command.) –
BC Decode Near Center, A barcode will not be decoded unless it is near the center of the FOV. (Supported with the BC_DECODE_NEAR_CENTER terminal command, which is part of the FINETUNE terminal command.) Default: Off
Expert Settings To modify expert settings parameters:
v2.4.1, Nov 2008
1.
Press Ctrl+A, or select Advanced Tuning from the Windows menu.
2.
Select Expert Settings in the pull-down window. ReadRunner displays the window shown in Figure 4–74.
HawkEye™ 1500 Series User Manual
4-113
Page 224
Chapter
4
ReadRunner
FIGURE 4–74. Advanced Window - Expert Settings
Undo Auto Learn Auto Learn Parameters
–
Auto Min Exposure, The minimum exposure time for auto photometry. Default: 30
–
Auto Max Exposure, The maximum exposure time for auto photometry. Default: 10030
–
Auto Min Gain, The minimum gain for auto photometry. Default: 150
–
Auto Max Gain, The maximum gain for auto photometry. Default: 410
–
Contrast Report - This is no longer used as a customer-settable parameter. If contrast is calibrated, it is reported as REFLECTANCE_CALIBRATED; if not calibrated, it is reported as UNCALIBRATED.
–
Cell Unit Report, The units to report cell size in MILS or PIXELS. Note: MILS is only valid if the camera is calibrated. See the HawkEye™ 1500 Series Verification Manual.
4-114
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008
Page 225
Fine Tuning & Monitoring Your Application
–
Aperture, Used with ISO15415 calibration. See the HawkEye™ 1500 Series Verification Manual.
Data Matrix Fine Tune To fine tune Data Matrix parameters: 1.
Press Ctrl+A, or select Advanced Tuning from the Windows menu.
2.
Select Data Matrix Fine Tune in the pull-down window. ReadRunner displays the window shown in Figure 4–75.
FIGURE 4–75. Advanced Window - Data Matrix Fine Tune
4 ReadRunner
Undo Auto Learn Auto Learn Parameters v2.4.1, Nov 2008
–
Position Enhance Enabled, Enabling this will instruct the algorithm to locate the four corners of the Data Matrix more precisely and in general reduce the number of error correction used for severely underprinted or overprinted symbols. The default is Off.
–
Intensity Enhanced Enabled, Designed to overcome dramatic intensity variation over the matrix border area. For example, certain poorly marked Data Matrix may have some cells that are almost invisible compared to the rest of the cells. Without enabling the option, the system may issue a status code indicating a certain edge cannot be found. Enabling the option will help read this type of Data Matrix more consistently. The default is Off.
HawkEye™ 1500 Series User Manual
4-115
Page 226
Chapter
4
ReadRunner
–
No Quiet Zone Clutter, Enabling the option will speed up the reading process when Data Matrix has sufficient quiet zone. With sufficient quiet zone, a Data Matrix with irregular, curved, or distorted border(s) can be read more efficiently with the option checked. The border problem typically is associated with low quality inkjet or dot peen marks or when the Data Matrix is imaged at an angle.
–
DM Ignore Single Edges, Allow a more severely damaged Data Matrix to be read by sacrificing speed.
–
DM Finetune Reserved, Reserved for future use.
–
DM Allow Steep Angle, In some Data Matrix reading applications it is not possible to set up the camera such that the focal plane is in parallel with the surface of the Data Matrix label. When the focal plane and the label surface form a steep angle, the Data Matrix in the image will have severe geometrical distortion. Enable the flag to read the distorted Data Matrix symbols.
–
DM Allow Severe Damage, Enabling the option will increase the robustness of the software in reading Data Matrix with severe border damages. To use it, first perform a successful Learn on a less damaged label. Then enable (check) the option to read labels with more border damages in Run mode.
–
DM Ensure ROI, Enabling the option will ensure that no Data Matrix is located unless it is fully inside the ROI.
–
DM Decode Near Center, A Data Matrix will not be decoded unless it is near the center of the FOV. Default: Off
–
DM Cell Outline, Enabling the option will help the algorithm decode a Data Matrix with outlined cells only. In this case, the On and Off cells have little or no contrast but they are separated by edges of the cells.
BC412 Parameters To modify BC412 parameters:
4-116
1.
Press Ctrl+A, or select Advanced Tuning from the Windows menu.
2.
Select BC412 Parameters in the pull-down window. ReadRunner displays the window shown in Figure 4–76.
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008
Page 227
Fine Tuning & Monitoring Your Application
FIGURE 4–76. Advanced Window - BC412 Parameters
Undo Auto Learn Auto Learn Parameters
Polarity, When the polarity is known, select either Dark on Light, or Light on Dark from the drop-down list. When polarity is not known, select AUTO (the default).
–
Start/Stop Checking, When ON, the HawkEye™ 1500 looks for a start pattern and a stop pattern on the BC412 barcode. Default: Off
–
Optional Check Sum Enable - Enable this item if the BC412 barcode contains a checksum character.
–
Optional Remove CS Display, If the CheckSum is present, should it be displayed?
–
Decode Forward/Backward, This is only useful when Start/Stop Checking is OFF. When Decode Forward/Backward is ON (the default) the HawkEye™ 1500 decodes data left-to-right. When Decode Forward/Backward is OFF, the HawkEye™ 1500 decodes data from right to left. This mode should not be used for SEMI BC412 barcode that contains both Start/Stop patterns and Check Sum. Default: On
QR Code Parameters To modify QR Code parameters:
v2.4.1, Nov 2008
1.
Press Ctrl+A, or select Advanced Tuning from the Windows menu.
2.
Select QR Code Parameters in the pull-down window. ReadRunner displays the window shown in Figure 4–77.
HawkEye™ 1500 Series User Manual
4-117
4 ReadRunner
–
Page 228
Chapter
4
ReadRunner
FIGURE 4–77. Advanced Window - QR Code Parameters
Undo Auto Learn Auto Learn Parameters
–
Finder Pattern Misalignment, Select the appropriate value to handle finder pattern alignment error when the cells in the finder pattern and the remaining cells do not line up correctly.
–
Polarity, Select Dark on Light, Light on Dark, or AUTO, depending on how the code is presented to the camera. If AUTO is not used, some performance enhancement should be seen by giving a hint to the locator.
Code 39 Parameters To modify Code 39 parameters: 1.
Press Ctrl+A, or select Advanced Tuning from the Windows menu.
2.
Select Code 39 Parameters in the pull-down window. ReadRunner displays the window shown in Figure 4–78.
FIGURE 4–78. Advanced Window - Code 39 Parameters
Undo Auto Learn Auto Learn Parameters
4-118
–
Optional Check Sum Enable - Enable this item if the Code 39 barcode contains a checksum character.
–
Optional Remove CS Display, If the CheckSum is present, should it be displayed?
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008
Page 229
Fine Tuning & Monitoring Your Application
I2of5 Parameters To modify I2of5 parameters: 1.
Press Ctrl+A, or select Advanced Tuning from the Windows menu.
2.
Select I2of5 Parameters in the pull-down window. ReadRunner displays the window shown in Figure 4–79.
FIGURE 4–79. Advanced Window - I2of5 Parameters
–
Optional Check Sum Enable - Enable this item if the I2of5 contains a checksum character.
–
Optional Remove CS Display, If the CheckSum is present, should it be displayed?
UPC Parameters To modify UPC parameters: 1.
Press Ctrl+A, or select Advanced Tuning from the Windows menu.
2.
Select UPC Parameters in the pull-down window. ReadRunner displays the window shown in Figure 4–80.
FIGURE 4–80. Advanced Window - UPC Parameters
Undo Auto Learn Auto Learn Parameters v2.4.1, Nov 2008
HawkEye™ 1500 Series User Manual
4-119
ReadRunner
4
Undo Auto Learn Auto Learn Parameters
Page 230
Chapter
4
ReadRunner
–
Output UPC as EAN, Specifies whether or not UPC data is displayed as EAN.
Debugging Images Configuring the Part Queue The Part Queue saves the result data to a file path (local or remote). You can configure the camera to save the data when it occurs (rather than in memory), or save the data on demand with a command. The records are stored as a re-usable queue; that is, when the queue is full, the newest record replaces the oldest record. Part Queue is loss-less; it will store a record for every image it sees. Note: The Part Queue uses the default ASCII Command port, which is port 49095. Telnet (which, by default, communicates on port 23) provides a connection to the Camera's low-level Monitor Shell for diagnostics purposes only. A special Shell command is available in this environment for sending HE15xx commands to the Camera via Telnet. The command has the following format: cmd “<HE15xx Reader ASCII Command String>” To configure the Part Queue:
4-120
1.
Press Ctrl+U, or select Configure Part Queue from the Settings menu.
2.
Click Yes when asked if you wish to control camera X. ReadRunner displays the Configure Part Queue window, as shown in Figure 4–81.
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008