The text of a manual · part 22 of 34
HawkEye 1500 Series User Manual, pages 211 to 220
Pages 211 to 220 of 338
The original document is the PDF (3.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan HE1510, RVSI CiMatrix HE1510 and Siemens HE1510
Page 211
Fine Tuning & Monitoring Your Application
FIGURE 4–68. Partial Data Matrix Image
SEE VIEW A
ONE SQUARE EQUALS ONE PIXEL
VIEW A
The X dimension, which refers to the narrowest bar and narrowest space, must consist of at least 2 pixels. In the case of a linear or stacked barcode, the minimum pixel width applies to the X dimension, as shown in Figure 4–69.
4 ReadRunner
FIGURE 4–69. X Dimension
X dimension = X dimension
Learning & Unlearning A learn sequence narrows down the parameters associated with a symbol, resulting in a more reliable decode of the same type of symbol. In most cases, learning speeds up the decoding time. •
Learn Photometry, Locks in the exposure and gain settings, and speeds up image acquisition.
•
Learn Decoder Settings, Locks the Data Matrix size, polarity, etc., and speeds up decoding. Otherwise, the camera looks for all types of symbols.
Once a learn sequence is initiated, all symbols that the HawkEye™ 1500 camera reads must be of the same type and size in order to be decoded. To display the Learn window: 1.
v2.4.1, Nov 2008
Click
HawkEye™ 1500 Series User Manual
4-101
Page 212
Chapter
4
ReadRunner
2.
Click Yes when asked if you wish to control camera X.
3.
Click ReadRunner displays one of the three Learn windows shown in Figure 4–70.
Note: Notice how the text changes for each button depending on the option chosen. FIGURE 4–70. Three Learn Windows
4.
Select one of the following: –
Learn Photometry Only, Specifies that the camera should learn only lighting information.
–
Learn Decoder Settings Only, Specifies that the camera should learn only decoder settings.
–
Learn Photometry and Decoder Settings, Specifies that the camera should learn both lighting information and decoder settings. This is the default.
After you click Learn in the Learn window, the HawkEye™ 1500 camera “learns” the information you specified.
4-102
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008
Page 213
Fine Tuning & Monitoring Your Application
Enabling Assisted Learn This command narrows down the parameters associated with a symbol by explicitly specifying the number of rows and columns, and the polarity. As with a learn, this results in a more reliable decode of the same type of symbol. In most cases, it also speeds up the decoding time. 1.
From the Learn window, select Learn Decoder Settings Only.
2.
Select (check) Enable Assisted Learn. ReadRunner displays the Enable Assisted Learn dialog box, as shown in Figure 4–71.
FIGURE 4–71. Enable Assisted Learn Dialog Box
3.
ReadRunner
4
Specify the following: –
Num Rows, The number of rows expected in the Data Matrix. Range: 8 - 144
–
Num Cols, The number of columns expected in the Data Matrix. Range: 8 - 144
–
Polarity, The expected polarity of the Data Matrix. Valid values are DARK ON LIGHT or LIGHT ON DARK
4.
ReadRunner also displays a box that you must place around the symbol. Use the four corners (one at a time) to move the box around the symbol.
5.
Click Done.
Unlearning To “unlearn” the learned information:
v2.4.1, Nov 2008
HawkEye™ 1500 Series User Manual
4-103
Page 214
Chapter
4
ReadRunner
1.
Click
2.
Click Yes when asked if you wish to control camera X.
3.
Click (Figure 4–70).
4.
Click Unlearn.
5.
Click Done.
ReadRunner displays the Learn window
Note: Unlearn “unlearns” what was set in a previous Learn.
Modifying Decoding Parameters This section describes modifying the following: •
“Data Matrix Parameters” on page 4-104
•
“Barcode Parameters” on page 4-109
•
“Expert Settings” on page 4-113
•
“Data Matrix Fine Tune” on page 4-115
•
“BC412 Parameters” on page 4-116
•
“QR Code Parameters” on page 4-117
•
“Code 39 Parameters” on page 4-118
•
“I2of5 Parameters” on page 4-119
•
“UPC Parameters” on page 4-119
Data Matrix Parameters To modify Data Matrix parameters:
4-104
1.
Press Ctrl+A, or select Advanced Tuning from the Windows menu.
2.
Select Data Matrix Parameters in the pull-down window. ReadRunner displays the window shown in Figure 4–72.
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008
Page 215
Fine Tuning & Monitoring Your Application
FIGURE 4–72. Advanced Window - Data Matrix Parameters
Unlearn Auto Learn Parameters
ReadRunner
4
–
Auto Learn Parameters, This button automatically learns the parameters for the current image.
–
Undo Auto Learn, This button unlearns parameters and resets them to their defaults.
–
Num Datamatrix, This pull down menu specifies the maximum number of Data Matrix symbols to find. Range: 0 (disable/no look) or 1 Default: 1
–
Num Columns, This pull down menu specifies the number of columns to expect in the Data Matrix symbol. Range: 8 - 144, or AUTO (autoselect)
v2.4.1, Nov 2008
HawkEye™ 1500 Series User Manual
4-105
Page 216
Chapter
4
ReadRunner
–
Num Rows, This pull down menu specifies the number of rows to expect in the Data Matrix symbol. Range: 8 - 144, or AUTO (autoselect)
–
ECC Level, This pull down menu specifies the expected Data Matrix Error Correction level. Valid values are AUTO, SPEC (default), 0, 50, 80, 100, 140, or 200. An ECC Level of 200 is the most common.
–
Polarity, This pull down menu specified the polarity. Valid values are:
–
–
–
4-106
•
DL, The Data Matrix is dark on light in the image.
•
LD, The Data Matrix is light on dark in the image.
•
AUTO, The Data Matrix is either DL or LD.
Image Style, This pull down menu selects the Data Matrix symbol image style. Valid values are: •
NORMAL, Data Matrix is imaged normally as opposed to mirrored.
•
MIRROR, A mirrored Data Matrix image is obtained.
•
AUTO, The Data Matrix is either NORMAL or MIRROR. This is the default.
Warp Type, This pull down menu specifies the matrix warping speed. Valid values are: •
Fast, The warping algorithm uses fast but less precise implementation. This is the default.
•
Slow, The warping algorithm uses slow but more precise implementation.
Orientation, This pull down menu specifies the matrix orientation in READ mode. When a Learn is performed, the orientation of the Data Matrix is set to one of the orientation values shown below. In Read mode, the controller is optimized to find the Data Matrix whose orientation is similar to the orientation determined in Learn. More specifically, if the Data Matrix orientation in Read mode stays within the +/-23° from the “learned” orientation, the controller will perform more reliably. If the orientation of the Data Matrix can be arbitrary, then
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008
Page 217
Fine Tuning & Monitoring Your Application you should change the orientation setting after the Learn by setting the orientation to AUTO. All measurements are assumed to be rotated in a CCW direction. Range: 1 - 8, or AUTO (default)
2 = 90°
3 = 180°
4 = 270°
5 = 45°
6 = 135°
7 = 225°
8 = 315°
4
Width/Height Ratio, This pull down menu specifies the expected width to height ratio when AUTO HEIGHT and WIDTH are selected. Range: 3 (3 = 0.3) - 50 (50 = 5.0), or AUTO (default)
–
Read Timeout, This parameter specifies the time to spend inspecting a symbol. For good, easy to read symbols, you might set this value this value lower than the default. For harder to read symbols, you might set this value higher. The purpose of this parameter is to minimize the time the camera takes trying to read a symbol that is bad before it simply fails the symbol and moves on to reading other symbols. For additional information, see “Read Timeout” on page 4-52. Range: 0 - 9999ms Default: 600ms
–
Cell Sample, This pull down menu specifies cell sampling. Range: 1 - 7 Default: 5
– v2.4.1, Nov 2008
Pixels per Cell, This pull down menu specifies the expected cell width. It is recommended that the Field of View (FOV) of the camera be chosen such that the Cell Size of the Data Matrix is between 5 and 10 pixels. The cell size can be estimated as follows using the values obtained after a successful learn:
HawkEye™ 1500 Series User Manual
4-107
ReadRunner
–
1 = 0°
Page 218
Chapter
4
ReadRunner
Matrix Height (in pixels) + Matrix Width (in pixels) __________________________________________ Number of Rows + Number of Columns Typically, the decode algorithm operates with maximum robustness when Pixel Per Cell is set to the estimated cell size. In the HawkEye™ 1500, the Pixel Per Cell is always set to the default value of 6 pixels after a learn in order to speed up the decode process for most of the applications. You can enhance robustness by adjusting this parameter. On the other hand, if the quality of the Data Matrix is high, then lowering the cell size value slightly will not affect the read rates but will further speed up the Read cycle. When the cell size drops to 3 pixels or less, however, the locate/decode time will increase and the robustness of the algorithm may be reduced. Range: 2 - 20 Default: 6 –
Matrix Height, This pull down menu specifies the Data Matrix height. Range: 20 - 1024, or AUTO (default)
–
Matrix Width, This pull down menu specifies the expected matrix width. Range: 20 - 1024, or AUTO (default)
–
4-108
Probe Direction, This pull down menu specifies the Probe direction. Valid values are: •
CRISS_CROSS, The first probe searches horizontally; the second probe searches vertically; the third probe searches horizontally at a different location; the fourth probe searches vertically at a different location and so on until (a) a Data Matrix is decoded, or (b) the search is completed within the ROI, or (c) the Read Time-out is reached. This is the default.
•
HORIZONTAL, All probes search horizontally at different locations until (1) a Data Matrix is decoded, or (b) the search is completed within the ROI, or (c) the Read Time-out is reached.
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008
Page 219
Fine Tuning & Monitoring Your Application
VERTICAL, All probes search vertically at different locations until (1) a Data Matrix is decoded, or (b) the search is completed within the ROI, or (c) the Read Time-out is reached.
•
HORI_VERT, First performs HORIZONTAL search. The VERTICAL search will not be invoked unless no Data Matrix is decoded in HORIZONTAL search. Note that half of the total Read Time-out value is allocated for HORIZONTAL search and half for VERTICAL search. This is the default.
•
VERT_HORI, First performs VERTICAL search. The HORIZONTAL search will not be invoked unless no Data Matrix is decoded in HORIZONTAL search. Note that half of the total Read Time-out value is allocated for HORIZONTAL search and half for VERTICAL search.
–
Probe Speed, This pull down menu specifies the Probe speed. Valid values are NORMAL (default), OVERDRIVE, or TURBO.
–
Probe Threshold, This pull down menu specifies the Probe threshold. Range: 5 - 100 Default: 18
Barcode Parameters To modify Barcode parameters:
v2.4.1, Nov 2008
1.
Press Ctrl+A, or select Advanced Tuning from the Windows menu.
2.
Select Barcode Parameters in the pull-down window. ReadRunner displays the window shown in Figure 4–73.
HawkEye™ 1500 Series User Manual
4-109
4 ReadRunner
•
Page 220
Chapter
4
ReadRunner
FIGURE 4–73. Advanced Window - Barcode Parameters
Undo Auto Learn Auto Learn Parameters
–
Auto Learn Parameters, This button automatically learns the parameters for the current image.
–
Undo Auto Learn, This button unlearns parameters and resets them to their defaults.
–
Num Barcodes, This pull down menu specifies the number of barcodes to decode. Range: 0 or 1 Default: 1
–
4-110
Horizontal Spacing, This pull down menu specifies the horizontal spacing.
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008