Page 201

Using ReadRunner

Reports & Images Over A Serial Connection You can connect to the HawkEye™ 1500 camera serially or over TCP/IP. When you connect serially, ReadRunner displays different buttons than the buttons you see when you are connected over TCP/IP, as shown in Figure 4–61. FIGURE 4–61. Buttons When Connected Serially

1.

Click Hook Reports.

2.

From the pull down menu, select All or Failures.

To display images: 1.

Click Hook Images.

2.

From the pull down menu, select the amount of compression each image should have: –

No Compression

–

4:1 Compression

–

8:1 Compression

–

16:1 Compression

–

32:1 Compression

Commands Sent To and Output From the Camera From the Terminal window, you can display commands sent to and received from the camera, display internal commands, program user buttons, and send remote commands to the camera. To display the Terminal window:

v2.4.1, Nov 2008

HawkEye™ 1500 Series User Manual

4 ReadRunner

Unlike when connected over TCP/IP, when connected over a serial connection you have to request that ReadRunner display reports and images. You can display both reports and images at the same time. To display reports:

4-91

Page 202

Chapter

4

ReadRunner

1.

Press Ctrl+T, or select Terminal Window from the Windows menu. ReadRunner displays the Terminal window, as shown in Figure 4–62.

FIGURE 4–62. ReadRunner Terminal Window

Command Text Box Program User Buttons Show Internal Messages Display Commands Sent To Camera Display Report Output From Camera Clear Terminal Window

The ReadRunner Terminal window displays output from the camera, commands sent to the camera, and internal messages. From this window, you can also program five user buttons (see “Programming User Buttons” on page 4-92). •

Clear Terminal Window, This button clears the terminal window.

•

Display Report Output From Camera, When selected, this button displays output from the camera. By default, this button is selected when you open the Terminal window.

•

Display Commands Sent To Camera, When selected, this button displays commands that you send to the camera. By default, this button is selected when you open the Terminal window.

•

Show Internal Messages, When selected, this button enables the display of every response (or “ack”) from a command sent to the camera. These responses are denoted with a “!”. By default, the display of these responses is disabled.

Programming User Buttons User buttons contain commands that are generated when you click one of the five user buttons in the Terminal window. When you click U, ReadRunner displays the User Buttons window, as shown in Figure 4–63.

4-92

HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008

Page 203

Using ReadRunner

FIGURE 4–63. User Buttons Window

ReadRunner

4

Specify a tool tip and the commands (you can specify more than one) for a user button. When you are finished, click OK. Note: A user button is enabled when both the Tool Tip text box and the Commands text box contain valid information.

v2.4.1, Nov 2008

•

Tool Tip, This text box contains the message that is displayed when the mouse pointer hovers over a user button. For example, if the Tool Tip for user button 1 contains “Virtual Trigger 1,” then “Virtual Trigger 1” is displayed when you put the mouse pointer on the 1.

•

Commands, This text box contains the actual remote commands that are generated when you click a user button. For more information about remote

HawkEye™ 1500 Series User Manual

4-93

Page 204

Chapter

4

ReadRunner commands, see the HawkEye™ 1500 Series Reference & Programmers Manual.

Sending Remote Commands to the Camera From the Terminal window, you can send remote commands to the camera in the Command Text Box area (see Figure 4–62). Note: De-select Display Report Output From Camera before you send remote commands to the camera. To display a list of remote commands, type: help

To display help for a specific command, type: help <command> Where: <command> is the name of the command

To display detailed information for a specific command, type: help <command> verbose Where: <command> is the name of the command verbose specifies that you want to see detailed information

Timing & Rate Information The Chart window displays the Timing rate and Read rate of the camera. To display the Charts window: 1.

4-94

Press Ctrl+H, or select Charting Window from the Windows menu. ReadRunner displays the Chart window, as shown in Figure 4–64 (Rate data displayed) and Figure 4–65 (Timing data displayed).

HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008

Page 205

Using ReadRunner

FIGURE 4–64. ReadRunner Charts Window, Rate Data

Display Rate Data Zoom Out Zoom In v2.4.1, Nov 2008

•

Zoom In/Out, Zoom In displays more detail; Zoom Out displays less detail.

•

Display Rate Data, Displays graphically how well the camera is able to read symbols as a percentage of successful reads (100% means zero noreads). Yellow indicates overall read rate since the camera was powered up. Green indicates read rate for the last 20 reads.

HawkEye™ 1500 Series User Manual

4-95

ReadRunner

4

This window displays rate information about the current images that the HawkEye™ 1500 camera is reading.

Page 206

Chapter

4

ReadRunner

FIGURE 4–65. ReadRunner Charts Window, Timing Data

Display Timing Data

This window displays timing information about the current images that the HawkEye™ 1500 camera is reading. •

Display Timing Data, Displays cycle time, read time, and acquire time graphically. Yellow indicates cycle time. Green indicates decode time. Red indicates acquisition time.

Information About Cameras on the Network The Network Overview window displays information about HawkEye™ 1500 cameras on the network. To display the Network Overview window: 1.

4-96

Press F12, or select Network Overview from the Windows menu. ReadRunner displays the Network Overview window, as shown in Figure 4–66.

HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008

Page 207

Using ReadRunner

FIGURE 4–66. ReadRunner Network Overview Window

Refresh Network Button

4 ReadRunner

Note: Click on a column heading to sort the column. –

Refresh Network, This button clears the screen and displays the current cameras on the network.

–

Name, The network name of the camera.

–

IP Address, The IP address of the camera.

–

Status, The status (ONLINE or OFFLINE) of the camera.

–

Controller, Identifies which connection (INTERNAL, COM2, an IP address) is “controlling” the camera.

–

Cycles, The total number of reads the camera has performed.

–

Passed, The number of successful reads the cameras has performed.

–

Failed, The number of unsuccessful reads the cameras has performed.

–

Alarms, The number (in red) of serious conditions that need attention.

–

Connections, The number of connections to the camera. Note: ReadRunner establishes three connections (image, result, command). You cannot change the number of connections other than through the process of performing some task using ReadRunner.

v2.4.1, Nov 2008

HawkEye™ 1500 Series User Manual

4-97

Page 208

Chapter

4

ReadRunner

–

SW Version, The version of software running on the camera. A +V after a version indicates that the camera has a valid Verification License key installed.

ReadRunner Version Number To display the ReadRunner version number, select About ReadRunner from the Help menu. ReadRunner displays the About ReadRunner window. Note: For proper operation, make sure the version of the software displayed in the Network Overview Window matches the ReadRunner revision used to connect to the camera. Contact Microscan to ensure you have the latest copy of software. •

4-98

Details, This button displays the Settings screen, as shown in Figure 4–67. When a camera is selected, the detail button displays the settings screen.

HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008

Page 209

Using ReadRunner

FIGURE 4–67. Settings Window

The RESET FACTORY command runs these settings

The RESET ALL command runs these settings

ReadRunner

4 v2.4.1, Nov 2008

–

Hardware Settings Installed in Manufacturing, These settings depend on the hardware purchased by the customer.

–

Customer Settings Installed in Manufacturing, These settings depend on the customer’s specifications.

–

Manufacturing Data, These are such things as MAC address, serial numbers, and so on.

HawkEye™ 1500 Series User Manual

4-99

Page 210

Chapter

4

ReadRunner

Note: The RESET FACTORY command restores the camera to factory settings and runs the stored hardware specific commands. The RESET ALL command restores the factory settings, runs the stored hardware commands, and runs the stored customer commands. For more information about either command, see the HawkEye™ 1500 Series Reference and Programmers Manual.

Fine Tuning & Monitoring Your Application The procedures in this section explain: •

“Selecting Symbologies (1D or 2D)” on page 4-100

•

“Learning & Unlearning” on page 4-101

•

“Modifying Decoding Parameters” on page 4-104

•

“Debugging Images” on page 4-120

Selecting Symbologies (1D or 2D) Camera Resolution and Pixels The number of pixels within the CCD array determines camera resolution. The more pixels in the captured image, the higher the resolution or quality of the image. Determining the correct camera resolution for the application is an important part of the HawkEye™ 1500 camera setup. The HawkEye™ 1500 requires that each cell in a Data Matrix symbol have a minimum pixel grid of 5x5 to obtain maximum performance. Ensure that you select a matrix size that allows you to obtain this pixel-to-cell ratio. The example in Figure 4–68 depicts a magnified view of a partial image. Notice that each cell contains the minimum number of pixels.

4-100

HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008