Page 191
Using ReadRunner
TABLE 4–10. UII/CPN with Data Fields
UII/CPN
DF0
Valid UII
UII:UII_data Example: UII:12345678
Constructed UII type Example: Contruct_1
Valid CPN
CPN:CPN_data Example: CPN:87654321
Constructed CPN type Example: PNR
Valid LBN
LBN:LBN_data Example: LBN:87654321
Constructed LBN type Example: 30T
Valid UII & CPN
UII:UII_data CPN:CPN_data Example: UII:12345678 CPN:87654321
Constructed UII/CPN type Example: Construct_1/PNR
Valid UII & LBN
UII:UII_data LBN:LBN_data Example: UII:12345678 LBN:87654321
Constructed UII/LBN type Example: Construct_1/30T
Valid UII & Invalid CPN
UII:UII_data (30P ERROR: xxxx)
Constructed UII type Example: Construct_1
UII:UII_data (PNR ERROR: xxxx)
Valid UII & Invalid LBN
4
UII:UII_data (240 ERROR: xxxx) UII:UII_data (30T ERROR: xxxx)
Invalid UII & Valid CPN
(UII ERROR: xxxx) CPN:CPN_data
Constructed CPN type: 30P, PNR, 240
Invalid UII & Valid LBN
(UII ERROR: xxxx) LBN:LBN_data
Constructed LBN type: 30T
Invalid UII
(UII ERROR: xxxx)
Original decoded data
(15434 ERROR: xxxx) Example: (UII ERROR: DATA ELEMENT CHARACTER) Invalid CPN
(30P ERROR:xxxx)
Original decoded data
(PNR ERROR:xxxx)
Invalid LBN
(240 ERROR:xxxx) (30T ERROR:xxxx) (15434 ERROR: xxxx)
Invalid UII & Invalid CPN Invalid UII & Invalid LBN
(UII ERROR: xxxx) (30P ERROR: xxxx)
Original decoded data
(UII ERROR: xxxx) (PNR ERROR: xxxx) (UII ERROR: xxxx) (240 ERROR: xxxx) (UII ERROR: xxxx) (30T ERROR: xxxx)
Notes: 1.
v2.4.1, Nov 2008
The error messages, xxxx, are listed in Table 3–6, “Report Error Codes,” on page 3-32.
HawkEye™ 1500 Series User Manual
4-81
ReadRunner
Content of Decoded Data Matrix
Page 192
Chapter
4
ReadRunner
2.
DF1 - DF7: If the UII/CPN field is “(15434 ERROR: xxxx)”, DF1 - DF7 are filled in with an empty string. Otherwise, the fields are used to display data elements. If there are less than seven data elements, an empty string is filled in at the end. If there are more than seven elements, only first seven elements are displayed.
3.
There is a space between UII and CPN in both tables (UII:12345678 CPN:87654321).
4.
The constructed UII type can be Contruct_1, Contruct_2, Construct_1_2, or IUID_EQUIVALENT.
5.
The constructed CPN type can be PNR, 30P, or 240. The constructed LBN type can be 30T.
Keyword Example Assume that you want to display formatted verification data every time there is a successful decode. You would do the following: 1.
Start ReadRunner.
2.
Click Add Camera to connect to a camera.
3.
From the Settings menu, click Output Settings.
4.
Click Yes when asked if you wish to control camera X. With the Decode Pass as (VERI_AIMDPM)(DATA)\0D\0A in Figure 4–54, ReadRunner displays the Output setting window shown in Figure 4–54.
FIGURE 4–54. Output Settings Window
5.
In the Decode Pass text box, type: (VERI_FORMATTED)
4-82
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008
Page 193
Using ReadRunner
6.
Click Apply and OK.
7.
From the Settings menu, click Symbology and Verification to display the Symbology / Verification window.
8.
Select AIM (ISO 16022).
9.
Click Apply and OK.
10.
From the Windows menu, click Terminal Window.
11.
Click the Display Report Output From Camera button. You will see a screen containing information similar to the following:
4 ReadRunner
FIGURE 4–55. Decode Pass Text Box Contains (VERI_FORMATTED)
12.
If you replace (VERI_FORMATTED) with (VERI_DETAIL) in the Decode Pass text box of the Output Setting window, the output would look similar to the following:
FIGURE 4–56. Decode Pass Text Contains (VERI_DETAIL)
v2.4.1, Nov 2008
HawkEye™ 1500 Series User Manual
4-83
Page 194
Chapter
4
ReadRunner
Finally, you can also customize the number of beeps that the camera emits on these pass/fail conditions. By default, the camera beeps once when the decode passes. You can configure each pass/fail condition with up to 3 beeps. The format string keywords are furthermore expanded to allow custom binary data to be output from the camera. The camera support the new keywords “(CDxx)” and “(IDxx)” where xx is a 2-digit decimal number. The number corresponds to a specific field of data, as listed in Table 4–11 and Table 4–12. All the data that was available in the Camera report and could only be accessed by programming can now be programmed into the Formatted Output strings sent by the camera over TCP. They are not available on standard output; just TCP1 through TCP4. TABLE 4–11. CD Fields
Field
4-84
Description
00
All Data
01
Overall Pass/Fail
02
Count of triggers
03
Count of passes
04
Count of failures
05
Count of successful locates
06
Count of failed locates
07
Count of successful decodes
08
Count of failed decodes
09
Count of successful matches
10
Count of failed matches
11
Count of alarms
12
Count of trigger overruns
13
Count of decode overruns
14
Count of acquisition timeouts
15
PID
16
Symbol Pass/Fail
17
Located / Not Located
18
Decoded / Not Decoded
19
Matched / Not Matched (0) (0 if matching is not active)
20
Detailed Decode Failure
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008
Page 195
Using ReadRunner
TABLE 4–11. CD Fields (Continued)
Field
Description
21
Overall AIM Verification Grade
22
Unformatted decode data Length/raw data
23
Photometry Settings Auto|Manual/Gain/Exposure
24
Image Timestamp
25
Image Data Raw Width/Height/Gray-scale Values
Field
Description
01
Image Data Bmp 32-bit Length/Binary Values
02
Image Data Tiff 32-bit Length/Binary values
All data is written in binary format on the corresponding output port (TCP only). Any 32-bit data is first converted to network order before being sent. The Enabled check box specifies whether or not the data in each text box gets sent out the serial port:
v2.4.1, Nov 2008
•
Header, Enter the header information you want displayed. When you select the checkbox for a given string, the header information precedes the text.
•
Trailer, Enter the trailer information you want displayed. When you select the checkbox for a given string, the trailer information follows the text.
•
Decode Pass, When checked, send the data in the text box out the serial port on every successful decode.
•
Decode Fail, When checked, send the data in the text box out the serial port on every unsuccessful decode.
HawkEye™ 1500 Series User Manual
4-85
ReadRunner
4
TABLE 4–12. ID Fields
Page 196
Chapter
4
ReadRunner
•
RT Error, A Runtime error, which includes any alarms, trigger overruns or process overruns. Currently, any alarm that is set is network related: connection was dropped, connection timed out, etc.
•
Locate Fail, When checked, send the data in the text box out the serial port on every unsuccessful locate.
•
Match String, A string to use for matching a decoded symbol. For example, if you are reading a serial number, you would use matching to validate that the decoded symbol matched against a certain string. Wildcards are supported: –
?, Any single character
–
*, Any preceding or following characters
•
Match Pass, When checked, send the data in the text box out the serial port on every successful match.
•
Match Fail, When checked, send the data in the text box out the serial port on every unsuccessful match.
Toggling the Target Laser The target laser helps you to align and adjust the position of the HawkEye™ 1515 and 1525 cameras. To toggle the state of the target laser, do one of the following: •
Click the target laser icon (see Figure 4–57) at the bottom of the main ReadRunner window.
FIGURE 4–57. Toggling Target Laser
Target Laser Off Target Laser On Target Laser Pulse Mode
•
From the Application Mode window, select or de-select one of the following from the Target Laser pulldown menu: –
4-86
Off
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008
Page 197
Using ReadRunner
On
–
Strobe (2 sec)
From the Settings menu, select Targeting Laser, and then select or de-select one of the following: –
Off
–
On
–
2 Second Strobe
DO NOT LOOK AT THE LASER. WHEN READING PARTS THAT ARE HIGHLY REFLECTIVE, BE CAREFUL THAT THE LASER IS NOT REFLECTED INTO SOMEONE’S EYE.
Toggling the Beeper You can toggle the beeper so that you hear/don’t hear beeps from the HawkEye™ 1500 camera. This overrides any settings in the Output Settings window (see “Output Format Strings” on page 4-71). To toggle the state of the beeper, do one of the following: 1.
Click the beeper icon (see Figure 4–58) at the bottom of the main ReadRunner window.
FIGURE 4–58. Toggling Beeper
Beeper Off Beeper On 2.
From the Settings menu, select Beeper. Note: A checkmark preceding Beeper in the Settings menu indicates that the beeper is on.
v2.4.1, Nov 2008
HawkEye™ 1500 Series User Manual
4-87
4 ReadRunner
•
–
Page 198
Chapter
4
ReadRunner
3.
From the keyboard, press Shift+F5.
Controlling the Beep You can control the beeper so that you hear/don’t hear beeps from the HawkEye™ 1500 camera under various conditions. To control the beeper: 1.
Do either of the following: a.
From the Settings menu, select Beep Control.
b.
From the keyboard, press Ctrl+B.
ReadRunner displays the Beep Control dialog box, as shown in Figure 4–59. FIGURE 4–59. Beep Control Dialog Box
2.
4-88
Specify the number of beeps, if any, you want for each condition. Your choices are: –
OFF
–
1 Beep
–
2 Beeps
–
3 Beeps
3.
Select the Enable Beeper checkbox.
4.
Close the Beep Control dialog box.
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008
Page 199
Using ReadRunner
Saving Parameters on the Camera to Flash This menu item saves the current memory settings to flash so that the camera is properly restored when it reboots. To save the parameters on the camera to flash: 1.
Press Ctrl+S, or select Save Parameters on Camera from the File menu.
2.
Click Yes when asked if you wish to control camera X. ReadRunner displays the message: Camera Parameters are saved to flash ReadRunner also saves the parameters to the ReadRunner.ini file.
Click OK.
4
Restoring Defaults Decoder Restoring defaults to the decoder is the same as doing an unlearn. To restore the default settings to the decoder: 1.
From the File menu, select Restore Defaults and then Decoder.
2.
Click Yes when asked if you wish to control camera X. ReadRunner restores the decoder settings to their defaults and saves them to Flash.
Application Mode Restoring defaults to the Application Mode options is the same as selecting Demo Mode: •
Continuous Triggers
•
No Retries
•
Illumination is on
•
Auto Photometry
To restore the default settings for the Application Mode: 1.
v2.4.1, Nov 2008
From the File menu, select Restore Defaults and then Application Mode.
HawkEye™ 1500 Series User Manual
4-89
ReadRunner
3.
Page 200
Chapter
4
ReadRunner
2.
Click Yes when asked if you wish to control camera X. ReadRunner restores the Application Mode options to the default information listed above and saves them to Flash.
Decoder & Application Mode To restore the default settings to both the decoder and the Application Mode options: 1.
Press Ctrl+Z, or select Restore Defaults and then Both from the File menu.
2.
Click Yes when asked if you wish to control camera X. ReadRunner restores the decoder settings and the Application Mode options to their defaults and saves them to Flash.
Displaying... Verification Report To display a Verification Report: 1.
Press F2, or select Verification Report from the Windows menu. ReadRunner displays the Verification Report window specific to the Verification Mode selected (DPM Verification in this example), as shown in Figure 4–60.
FIGURE 4–60. Verification Report Window
4-90
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008