Page 231

Fine Tuning & Monitoring Your Application

FIGURE 4–81. Configure Part Queue Window

3.

v2.4.1, Nov 2008

Specify parameters from the following pull down menus: –

Part Queue On/Off, Enables (On) or disables (Off) the part queue.

–

Qualifier, Specifies what you want to store in the part queue: •

All

•

Passed

•

Failed

•

Verify Good, Fair, Poor, Failed

•

Verify Good, Fair, Poor

•

Verify Good

•

Verify Fair

•

Verify Poor

•

Verify Failed

HawkEye™ 1500 Series User Manual

4-121

ReadRunner

4

Page 232

Chapter

4

ReadRunner

–

•

Verify Poor, Failed

•

Verify Fair, Poor, Failed

Specific Failure, Specifies what kind of failures you want to store: •

All

•

Location Failure

•

Decode Failure

•

Match Failure

•

Runtime Error

Note: This field is activated when you select Failed for the Qualifier parameter. –

Maximum Records, Specifies the maximum number of images you want to store in the part queue. The approximate limit will be displayed next to this field, and depends on the amount of memory on the camera and the PartQ options selected.

–

Save Method, The Part queue must be activated for either mode to function. Then, you can specify the qualifier and number of records to save. Note: When left at zero, Maximum Records has a different meaning for each mode. •

Save in camera memory, This is the default. All available memory stores read records. Typically, there is enough space for the last 30 records (when programmed to store Images as well), and about 5000 records (when programmed to store reports without images). Older records are dropped to make room for new ones over time such that the last N records are always available in memory. Note: When programmed in this mode, records saved on the camera can be retrieved by a remote client at any time over TCP or Serial. Retrieving records over TCP does not impact performance of the Reader; however retrieving reports over Serial will degrade the performance of the Reader.

4-122

HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008

Page 233

Fine Tuning & Monitoring Your Application

You can use the part queue mechanism to buffer Read cycle reports over time (30 cycles with images, 5000 cycles without) such that, if the communication to the camera over TCP is lost, past read data can be siphoned out of the camera once the client reconnects. This logic can be easily initiated by the client on reconnects by sending the PARTREQ command. Save on remote system (FTP), Records are written to the remote host with a unique cycle number in their file name. There is no wrap-around, so, if they are not purged on the remote host, this could potentially fill-up the remote disk file system. When the Maximum Records is non-zero, the records will wrap around after the Nth one has been saved, re-using the file names. When you select Save on remote system (FTP), the Host IP (i.e., xx.xx.xx.xx, for example 10.2.1.98) and path needs to be specified. The Path uses the UNIX directory convention “/” as a directory separator. Optionally, Results and/or Images can be saved. An FTP server must be running on the destination host for this option to function. The FTP Server must be configured with a “Camera” Account as follows: User Name: target Password: password The credentials of that special user must be set to have write permissions to the destination PATH entered in the Configure Part Queue form. The root of the path should be restricted by the FTP Server for that account if desired. Note: Selecting this option will drastically impact the performance of the camera. The Read Rate (i.e. Reads/sec) will significantly decrease; therefore, this option should only be used in special tuning or debugging situation. If the Reader job is triggered, the camera may overrun; you need to make sure that there is enough idle time between triggers to save the data via FTP. For a clean 100BaseT Ethernet Network, it should take in the order of 100 to 200 msec to send an image via FTP. This mechanism does not guarantee that every read cycle will be v2.4.1, Nov 2008

HawkEye™ 1500 Series User Manual

4-123

4 ReadRunner

•

Page 234

Chapter

4

ReadRunner saved via FTP. Use Save to Memory if capturing the last N records is important without missing one. Uploading using FTP with QueueView can cause lost data. It was discovered that a customer with more than one HawkEye 1500 Smart Camera reader connected to an FTP server and using high trigger rates, could lose a text or image file due to the limitations of a network data throughput. A FTP server, while capable of supporting multiple connections, is not always able to handle a new connection request at a particular time and returns an ECONNREFUSED status to the HawkEye 1500 Smart Camera reader. This error is detected and multiple retries are attempted to provide a very high likelihood of success. We therefore recommend the following guidelines be considered when using the QueueView FTP feature:

4-124

–

The transfer of files becomes part of the decision process for determining worst-case HawkEye 1500 Smart Camera reader trigger rates. We recommend no less than 3 seconds between triggers with 1 HawkEye 1500 Smart Camera. Triggering faster than the files can be successfully transferred will cause “Decode Process Overruns” with loss of data.

–

The number of HawkEye 1500 Smart Camera readers on a network segment communicating to a single FTP server also should be limited to prevent contention for access to the FTP server. We recommend that the minimum trigger interval, on a single HawkEye 1500 Smart Camera application using the QueueView FTP feature, be 3 seconds. For additional HawkEye 1500 Smart Cameras, this minimum trigger interval should then be increased by 1 second for each HawkEye 1500 Smart Camera added. For example, when using 2 HawkEye 1500 Smart Cameras, the interval between triggers should be a total of 4 seconds (3 seconds plus 1 second for the additional HawkEye 1500 Smart Camera reader equals 4 seconds). When using 5 HawkEye 1500 Smart Cameras, the interval between triggers should be a total of 7 seconds (3 seconds plus 1 second for each of the 4 additional HawkEye 1500 Smart Camera readers = 7 seconds). Adding additional FTP servers and network segments should be considered to keep minimum trigger rates low.

HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008

Page 235

Fine Tuning & Monitoring Your Application

4.

v2.4.1, Nov 2008

The worst-case bandwidth requirements on the network segment should never exceed 40% of the theoretical bandwidth. If the network is 10BaseT, 40% x 10,000,000 bits per second / 8 bits per byte = 500Kbytes/second. A HawkEye 1500 Smart Camera reader image is 326Kbytes and a text report is 1Kbyte. With FTP protocol overhead added, one HawkEye 1500 Smart Camera reader's image and text report takes nearly all of the available bandwidth for 1 second.

–

The HawkEye 1500 Smart Camera will attempt to connect to the FTP server for each text or image file result. In the event that a connection fails, the HawkEye 1500 Smart Camera will retry this connection up to 100 times, spaced from 1 to 10 ms apart. In the event of an unsuccessful FTP connection, the HawkEye 1500 Smart Camera will stop retrying and get ready to accept the next trigger. This will result in data loss. If additional triggers come in before the FTP transfer is done on the buffered data, it will result in data loss. If the network is broken, it will result in data loss. Note that there is no nonvolatile storage on the HawkEye 1500 Smart Camera so a power failure will result in lost data.

–

Host IP, The IP address of the system running the FTP server.

–

Path, The directory on the FTP server where the files will be written.

–

Save Results (.txt), Yes or No. This only applies to FTP reports.

–

Save Images (.bmp), Yes or No. This also applies to “Save in camera memory” save method.

–

Max FTP Records, Is either of the following: •

0 = Records with the file names containing a 9 digit decimal representation of the cycle count “_000000000_”.

•

1-9999 = Sequentially labeled records with the file names containing a 4 digit representation “_0000_”, wrapping at N records and overwriting old records

Click OK.

HawkEye™ 1500 Series User Manual

4-125

4 ReadRunner

–

Page 236

Chapter

4

ReadRunner

Uploading Images Using QueueView You can use ReadRunner to activate the Part Queue on the camera and save specific images inline with the running inspection. You can save All images, Passed images, or Failed images (decode failures, locator failures, match failures, or runtime errors). You can specify the number of records to store (the maximum is up to the amount of memory on the camera). Once images are stored on the camera, you can use QueueView to pull them off the camera, examine them, and save them to disk. To start QueueView and upload records: 1.

Select Start, Programs, ReadRunner 2.4, Utilities, and finally HawkEye QueueView. The QueueView window is displayed. Figure 4–82 describes the QueueView options and buttons.

FIGURE 4–82. QueueView Window

Save Images as Bitmap/TIFFs Back / Forward Clear the images from camera without uploading Upload Part Queue (clear from camera)

List of Cameras

4-126

Refresh Part Queue Information

HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008

Page 237

Fine Tuning & Monitoring Your Application

–

List of Cameras, Select the camera whose part queue you want to view.

You can edit the text in this drop down list of cameras to enter a static IP address for a reachable camera on a different subnet:

Highlight <Enter_Static_IP_Address>.

b.

Enter the IP address and press Return.

–

Refresh Part Queue Information, This button clears the screen and displays the most current cameras on the network.

–

Upload Part Queue (clear from camera), Uploads the images to QueueView and removes them from the camera.

–

Clear images from camera without uploading, If you click this button, QueueView displays the Are you sure... dialog box, as shown in Figure 4–83.

FIGURE 4–83. Are you sure? Dialog Box

–

Arrow Keys, Allows you to move through all the images uploaded from the part queue. When you click on a specific image, the report information for that image is displayed in the report panel.

–

Save Images, Select one of the following: •

Save Current Image, Saves the current image.

•

Save All Images, Saves all images.

•

Select Image Folder, Specifies the folder where you want to save the image or images.

Note: These buttons are activated after you upload the part queue.

v2.4.1, Nov 2008

HawkEye™ 1500 Series User Manual

4-127

4 ReadRunner a.

Page 238

Chapter

4

ReadRunner

–

Save Images as Bitmap, Specifies that QueueView should save images onto the PC as .bmp files.

–

Save Images as TIFFs, Specifies that QueueView should save images onto the PC as .tif files. This is the default.

–

Verify, If this report contains verification results, then this button activates a verification report display.

2.

From the List of Cameras pull down menu, select a camera.

3.

Click Upload Part Queue (clear from camera).

QueueView loads the entire Part Queue.

Saving Images to the PC Using QueueView To save images to the PC using QueueView: 1.

Click either Save Images as Bitmap or Save Images as TIFFs.

2.

Select Select Image Folder.

QueueView displays a screen similar to the following: FIGURE 4–84. Select Folder Window

4-128

HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008

Page 239

Fine Tuning & Monitoring Your Application

3.

Specify where you want to save the images. Click OK.

4.

Click either Save Current Image or Save All Images.

QueueView saves the image(s) to the specified location on the PC. The file names of the saved images have the following format: sqa001_000001173.tif File Extension Cycle Number Camera Name

Saving the Current Image To save the current image, press F9, or select Save Current Image from the File menu. ReadRunner saves the current image in the Images folder within the ReadRunner folder. The file name of the saved image has the following format:

ReadRunner sqa001_000001173.tif File Extension Cycle Number Camera Name

Loading Image Files to the Camera If the camera fails to read an image, you can save that failed image onto the PC (see “Configuring the Part Queue” on page 4-120), and then load the image back to the camera for debugging purposes. To load an image file to the camera:

v2.4.1, Nov 2008

1.

Press Ctrl+I, or select Load Image Files To Camera from the File menu.

2.

Click Yes when asked if you wish to control camera X. ReadRunner displays the Select Images window, as shown in Figure 4–85.

HawkEye™ 1500 Series User Manual

4

4-129

Page 240

Chapter

4

ReadRunner

FIGURE 4–85. Select Images Window

3.

4.

Navigate to the appropriate folder, select the file(s) you want to load onto the camera, and click Open. ReadRunner loads the file(s) onto the PC for debugging. –

If the failure was a decode failure, you will want to modify the advanced parameters until it passes (see “Modifying Decoding Parameters” on page 4-104).

–

If the failure was a location failure, you may need to adjust the ROI (see “Defining the Region of Interest” on page 4-26).

Press Ctrl+Q to return the camera to acquisition (see “Returning the Camera to Acquisition” on page 4-130).

Returning the Camera to Acquisition After loading an image file to the HawkEye™ 1500 camera for reading, you can return the camera to acquisition using this menu item. To return the camera to acquisition:

4-130

1.

Press Ctrl+Q, or select Use Camera for Acquisition from the File menu.

2.

Click Yes when asked if you wish to control camera X. ReadRunner resumes reading images placed in its field of view.