The text of a manual · part 9 of 28
HawkEye 1500 Series Reference & Programmers Manual, pages 81 to 90
Pages 81 to 90 of 276
The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Microscan HE1510, RVSI CiMatrix HE1510 and Siemens HE1510
Page 81
In some Data Matrix reading applications, it is not possible to set up the camera such that the focal plane is in parallel with the surface of the Data Matrix label. When the focal plane and the label surface form a steep angle, the Data Matrix in the image will have severe geometrical distortion. Use the following steps to read severely distorted Data Matrix in any orientation:
• a.
Unlearn.
b.
Set Number of Data Matrices to Decode to 1.
c.
In Finetune Method, enable/check Allow Steep Angle. Now, the system is ready to read distorted Data Matrix in Run mode.
bit 6, DM_ALLOW_SEVERE_DAMAGE {ON/OFF} Default=Off Enabling this option increases the robustness of the software in reading Data Matrix with severe border damages. To use it, first perform a successful Learn on a less damaged label. Then, enable (check) the option to read labels with more border damages in Run mode.
• bit 7, DM_ENSURE_ROI {ON/OFF} Default=Off Enabling this option ensures that no Data Matrix is located unless it is fully inside the ROI.
• bit 8, DM_DECODE_NEAR_CENTER {ON/OFF} Default=Off Enabling this option allows a Data Matrix or barcode to be decoded only if the center of the ROI is inside the Data Matrix or barcode.
• bit 9, BC_DECODE_NEAR_CENTER {ON/OFF} Default=Off Enabling this option allows a Data Matrix or barcode to be decoded only if the center of the ROI is inside the Data Matrix or barcode.
• bit 10, DM_CELL_OUTLINE {ON/OFF} Default=Off Enabling this option helps the algorithm decode a Data Matrix with outlined cells only. In this case, the On and Off cells have little or no contrast but they are separated by edges of the cells.
Use the following command to set more than one flag at a time: FINETUNE ENABLEMASK 0x26 where the bits for each selected option are set in the mask.
Rev 2.4.1, Nov 2008
HawkEye 1500 Reference & Programmers Manual
1-67
1 Remote Commands Reference
FINETUNE
Page 82
Chapter
1
Remote Commands Reference
Alternatively, you can set each of the individual FINETUNE parameters singly. For example: BC_DECODE_NEAR_CENTER {ON/OFF} DM_ALLOW_SEVERE_DAMAGE {ON/OFF} DM_ALLOW_STEEP_ANGLE {ON/OFF} DM_CELL_OUTLINE {ON|OFF} {ON/OFF} DM_DECODE_NEAR_CENTER {ON/OFF} DM_ENSURE_ROI {ON/OFF} DM_FINETUNE_RESERVED {ON/OFF} DM_IGNORE_SINGLE_EDGES {ON/OFF} INTENSITY_ENHANCE_ENABLED {ON/OFF} NO_QUIET_ZONE_CLUTTER {ON/OFF} POSITION_ENHANCE_ENABLED {ON/OFF}
1-68
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov
Page 83
HEADER This command sets the Decode Output header to the indicated string. Use this command to specify the text that will precede the decoded output. For example, assume: •
HEADER string = “ACME Part Number: ”
•
Decoded output = 123456
The output would look like: ACME Part Number: 123456
Syntax HEADER {““string””} Where: string, Is 1 to 80 characters. The default is NULL. String may include nonprintable control characters in the following format: \0d = CR \0A = LF The string may include keyword substitution:
Rev 2.4.1, Nov 2008
–
CHECKSUM, This keyword expands to the checksum of the characters in the appropriate Output Format String where the (CHECKSUM) keyword is inserted. The two character ASCII value representation of the Hexadecimal checksum (for example, 2E) is substituted in the Output string. The checksum is calculated as the Exclusive OR (XOR) of all the characters up to the (CHECKSUM) keyword, including the Header and the Trailer characters if (CHECKSUM) is placed at the end of the trailer string.
–
TIMESTAMP, This keyword will be substituted with the current date and time.
HawkEye 1500 Reference & Programmers Manual
1-69
1 Remote Commands Reference
HEADER
Page 84
Chapter
1
Remote Commands Reference
HEIGHT This command sets the expected Data Matrix height. Note: See also “RATIO” on page 1-142 and “WIDTH” on page 1-202.
Syntax HEIGHT {opt} Where: opt, Is either of the following:
1-70
– height, Range: 20 - 1024
–
AUTO, Autoselect (default)
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov
Page 85
HELP This command displays remote commands and descriptions of how to use them. •
List all available commands: HELP
•
List help for a command: HELP {cmd} Where: –
• cmd, Most remote commands
List detailed help for a command: HELP {cmd} V[ERBOSE] Where:
Rev 2.4.1, Nov 2008
– cmd, Select remote commands
–
VERBOSE, Display detailed information about the command
HawkEye 1500 Reference & Programmers Manual
1-71
1 Remote Commands Reference
HELP
Page 86
Chapter
1
Remote Commands Reference
ILLUMINATION This command selects the lighting for the HawkEye™ 1500.
Syntax ILLUM[INATION] {opt} Where: opt, Is one of the following:
1-72
–
OFF, Use ambient lighting.
–
ON, Use constant lighting (default).
–
EXT, Use external lighting.
–
STROBE, Use strobed lighting.
–
POWER[_STROBE], Use power stobed lighting.
–
ON_AND_PSTROBED, Constant on with power strobing at trigger.
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov
Page 87
INFORM This command specifies whether or not each issued command reports back the state of the command just changed.
Syntax INFORM {opt} Where: opt, Is either of the following:
Rev 2.4.1, Nov 2008
–
ON
–
OFF (default)
HawkEye 1500 Reference & Programmers Manual
1-73
1 Remote Commands Reference
INFORM
Page 88
Chapter
1
Remote Commands Reference
INTENSITY_ENHANCE_ENABLED See “FINETUNE” on page 1-66.
1-74
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov
Page 89
IO_MODE This command selects the GPIO output mode.
Syntax IO_MODE {mode} [duration] Where: mode, Is one of the following: –
NONE
–
DV_2LINE_HS, HandShake mode with multiplexed (GOOD, FAIR, POOR, Locate Failure) and DataValid lines assigned. In this mode, the status is NOT cleared until the trigger goes away.
–
DV_3LINE_HS, HandShake mode with GOOD, FAIR, POOR, and DataValid lines assigned. In this mode, the status is NOT cleared until the trigger goes away.
–
DV_2LINE_PULSE, PULSE/PIPELINED with multiplexed (GOOD, FAIR, POOR, Locate Failure) and DataValid lines assigned with DataValid duration: 0 - 30,000ms.
–
DV_3LINE_PULSE, PULSE/PIPELINED with GOOD, FAIR, POOR, and DataValid lines assigned with DataValid duration: 0 30,000ms.
–
DV_HS, HandShake mode with OPT1 = Pass, OPT2 = Fail, for duration.
–
DV_PULSE, PULSE/PIPELINED with OPT1 = Pass | Fail, OPT3 = Data Valid, for duration.
–
HE_HS, HandShake Mode with OPT1 = Pass, OPT2 = Fail.
–
HE_PULSE, PULSE/PIPELINED Mode with OPT1 = Pass, OPT2 = Fail, for duration.
duration, Is the pulse duration. In pulse mode, the status is NOT cleared until the trigger goes away. The range is 0 - 30,000ms.
Rev 2.4.1, Nov 2008
HawkEye 1500 Reference & Programmers Manual
1 Remote Commands Reference
IO_MODE
1-75
Page 90
Chapter
1
Remote Commands Reference
IOASSIGN This command allows variables defined with the SET_CRITERIA command to be assigned to digital output lines. Note: Use the SET_CRITERIA command to configure variable_name definitions before assigning them to an output bit
Syntax IOASSIGN {BIT} {variable_name} Where:
1-76
•
BIT, A valid output point. Valid points include OPTO_OUT1 to OPTO_OUT3 and GPIO_OUT1 to GPIO_OUT4.
• variable_name, Is one of the following: –
ANGLE_FAILURE, Signals when the measured angle is outside of the user’s process limits
–
LOCATE_FAILURE, may be used as an overall indicator or masked to signal particular types of locate failures.
–
DECODE_FAILURE, If used when Match Mode is enabled, it allows the user to distinguish between NO MATCH with a successful Decode and NO MATCH with an unsuccessful Decode
–
RTE, Run time error, including Trigger Overruns, Decode Overruns, and Network errors
–
PASS, may also represent a MATCHED state if a Match Mode is enabled
–
FAIL, may also represent a NO MATCH state if a Match Mode is enabled
–
DV, Data Valid
–
GOOD, (used by the Verification option)
–
FAIR, (used by the Verification option)
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov