The text of a manual · part 8 of 28
HawkEye 1500 Series Reference & Programmers Manual, pages 71 to 80
Pages 71 to 80 of 276
The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Microscan HE1510, RVSI CiMatrix HE1510 and Siemens HE1510
Page 71
DM_DECODE_NEAR_CENTER See “FINETUNE” on page 1-66.
Rev 2.4.1, Nov 2008
HawkEye 1500 Reference & Programmers Manual
1 Remote Commands Reference
DM_DECODE_NEAR_CENTER
1-57
Page 72
Chapter
1
Remote Commands Reference
DM_ENSURE_ROI See “FINETUNE” on page 1-66.
1-58
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov
Page 73
DM_FINETUNE_RESERVED See “FINETUNE” on page 1-66.
Rev 2.4.1, Nov 2008
HawkEye 1500 Reference & Programmers Manual
1 Remote Commands Reference
DM_FINETUNE_RESERVED
1-59
Page 74
Chapter
1
Remote Commands Reference
DM_IGNORE_SINGLE_EDGES See “FINETUNE” on page 1-66.
1-60
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov
Page 75
DOMAIN This command sets the default TCP/IP domain. For example: acut.com
Syntax DOMAIN {domain name}
Rev 2.4.1, Nov 2008
HawkEye 1500 Reference & Programmers Manual
1 Remote Commands Reference
DOMAIN
1-61
Page 76
Chapter
1
Remote Commands Reference
DWELLTIME This command sets the dwell time of the decoder.
Syntax DWELLTIME {opt} Where: opt, Is the time in milliseconds: Range: 0 - 60 ms Default: 5 ms
1-62
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov
Page 77
ECC This command sets Data Matrix expected Error Correction level. ECC 200 employs Reed-Solomon error correction and is recommended for new applications. Other ECC levels (000, 050, 080, 100, 140) use the convolutional error encoding. ECC250 is customer-specific coding. The default value SPEC allows the algorithm to decode ECC000, 050, 080, 100, 140, and 200 that are included in the AIM/ISO Data Matrix Specification. If not specified, the older non-standard Data Matrix such as ECC120 can also be decoded.
Syntax ECC {level} Where: level, Is one of the following:
Rev 2.4.1, Nov 2008
–
0
–
50
–
80
–
100
–
140
–
200
–
AUTO
–
Spec (default)
HawkEye 1500 Reference & Programmers Manual
1-63
1 Remote Commands Reference
ECC
Page 78
Chapter
1
Remote Commands Reference
EIPENABLE This command enables/disables Ethernet/IP communications. Note: You must reboot the camera after enabling/disabling Ethernet/IP.
Syntax EIPENABLE {opt} Where: opt, Is either of the following:
1-64
–
Y or ON, Enable Ethernet/IP.
–
N or OFF, Disable Ethernet/IP (default)
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov
Page 79
ENSURE CENTERED This command specifies whether or not the image needs to be centered.
Syntax ENSURE CENT[ERED] {opt1} {opt2} Where: opt1, Is either of the following: –
BARCODE, The camera decodes barcodes when the laser (central) line passes through all the bars and spaces.
–
DM, The camera decodes Data Matrix when the center point of image is inside the Data Matrix opt2, Is either of the following:
Rev 2.4.1, Nov 2008
–
ON
–
OFF (default)
HawkEye 1500 Reference & Programmers Manual
1 Remote Commands Reference
ENSURE CENTERED
1-65
Page 80
Chapter
1
Remote Commands Reference
FINETUNE This command controls all decoder fine tuning options. It allows you to select the combination of decoder fine tuning options. By default, FINETUNE is ON.
Syntax FINETUNE {ON | OFF} FINETUNE ENABLEMASK {mask} • bit 0, POSITION_ENHANCE_ENABLED {ON/OFF} Default=Off Enabling this option allows the algorithm to locate more precisely the four corners of the Data Matrix, and may improve the decode capability. This mode is left here for compatibility purposes.
• bit 1, INTENSITY_ENHANCE_ENABLED {ON/OFF} Default=Off Designed to overcome dramatic intensity variation over the matrix border area. For example, certain poorly marked Data Matrices may have some cells that are almost invisible compared to the rest of the cells. Without enabling the option, the system may issue a status/error code, indicating a certain edge cannot be found. Enabling the option will help read this type of Data Matrix more consistently.
• bit 2, NO_QUIET_ZONE_CLUTTER {ON/OFF} Default=Off Enabling this option speeds up the reading process when Data Matrix has sufficient quiet zone. With sufficient quiet zone, a Data Matrix with irregular, curved, or distorted border(s) can be read more efficiently with the option checked. Typically, the border problem is associated with low quality inkjet or dot peen marks or when the Data Matrix is imaged at an compound angle.
• bit 3, DM_IGNORE_SINGLE_EDGES {ON/OFF} Default=Off Enabling this option allows the software to ignore single edges surrounding the Data Matrix in the image.
• bit 4, DM_FINETUNE_RESERVED {ON/OFF} Default=Off This option is reserved for future implementation.
•
1-66 bit 5, DM_ALLOW_STEEP_ANGLE {ON/OFF} Default=Off
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov