Page 91
–
POOR, (used by the Verification option)
Use the CLEAR keyword to disable an I/O assignment; for example: IOASSIGN GPIO_OUT2 CLEAR You can display the state of a single assignment; for example: IOASSIGN GPIO_OUT2 ? You can display the state of all assignments; for example: IOASSIGN ?
Rev 2.4.1, Nov 2008
HawkEye 1500 Reference & Programmers Manual
1 Remote Commands Reference
IOASSIGN
1-77
Page 92
Chapter
1
Remote Commands Reference
IP This command sets up the static IP address when DHCP is disabled. The camera name is used for DHCP or static addressing.
Syntax IP {cameraname} {ipaddress} {subnetmask} {gateway} Where: cameraname, Is the name of the camera. ipaddress, Is the static IP address. subnetmask, Is the subnet mask. gateway, Is the gateway address.
1-78
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov
Page 93
IPCONFIG This command returns the current name, IP address, and subnet mask of the camera.
Syntax IPCONFIG {hostname} {ipaddress} {subnetmask} Where: hostname, Is the name of the camera ipaddress, Is the IP address of the camera subnetmask, Is the subnet mask of the camera
Rev 2.4.1, Nov 2008
HawkEye 1500 Reference & Programmers Manual
1 Remote Commands Reference
IPCONFIG
1-79
Page 94
Chapter
1
Remote Commands Reference
LEARN This command initiates a learn sequence. The LEARN command narrows down the parameters associated with a symbol. This results in a more reliable decode of the same type of symbol. In most cases, it speeds up the decoding time. You can use the LEARN command in combination with the ASSIGN, PID, STORE, and TRIG commands. Once the LEARN command is issued, all symbols that are being read must be of the same type and size in order to be decoded. To open up the decoder to all possible types of symbols again, issue the UNLEARN command. Note: See “LEARNASSIST” on page 1-82 and “UNLEARN” on page 1-188. You can also issue a LEARN command using QuicSet®: 1.
Enter QuicSet® by pressing the QuicSet® recessed button (using a paper clip) once.
2.
Learn the next acquired image by pressing the recessed button two more times quickly.
3.
Exit QuicSet® by pressing the recessed button again.
Syntax LEARN {opt} Where: opt, Is one of the following: –
Both (default)
–
1D
–
2D
–
None
–
Calibrate, Use this command to perform reflectance calibration: 1.
1-80
Center the Calibration Data Matrix in the FOV.
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov
Page 95
Rev 2.4.1, Nov 2008
2.
Enter “contrast” using the TARGET_CALIB_CONTRAST command (see page 1–169).
3.
Enter “r_max” using the TARGET_CALIB_REFLECTANCE (page 1–170).
HawkEye 1500 Reference & Programmers Manual
1 Remote Commands Reference
LEARN
1-81
Page 96
Chapter
1
Remote Commands Reference
LEARNASSIST This command narrows down the parameters associated with a symbol. This results in a more reliable decode of the same type of symbol. In most cases, it speeds up the decoding time. Note: See also “LEARN” on page 1-80 and “UNLEARN” on page 1-188.
Syntax LEARNASSIST {p1x,p1y,p2x,p2y,p3x,p3y,p4x,p4y} {rows}{cols}{polarity} Where: p1x,p1y,p2x,p2y,p3x,p3y,p4x,p4y, Clockwise, the x and y of the four corners. rows, The number of rows to expect in the Data Matrix symbol: Range: 8 - 144, or AUTO, Autoselect (default) cols, The number of columns to expect in the Data Matrix symbol: Range: 8 - 144, or AUTO, Autoselect (default) polarity, Is one of the following:
1-82
–
Dark on light
–
Light on dark
–
AUTO (default)
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov
Page 97
LEARNCANCEL This command cancels a learn request that is waiting to be executed when the next trigger occurs. This occurs when you issue a learn and the unit is in TRIG T mode, waiting for a trigger.
Syntax LEARNCANCEL
Rev 2.4.1, Nov 2008
HawkEye 1500 Reference & Programmers Manual
1-83
1 Remote Commands Reference
LEARNCANCEL
Page 98
Chapter
1
Remote Commands Reference
LEARNEX This command can optionally learn Decoder and/or Photometry values. Note: This is an action command. It cannot be store or queried.
Syntax LEARNEX {Decoder} {Photometry} Decoder, Learn either 1D or 2D; whatever is in the field of view. •
BOTH
•
1D
•
2D
•
NONE
•
CALIBRATE
Photometry, Learn the Gain and Exposure and leave in Manual mode.
1-84
•
PHOTO
•
NONE
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov
Page 99
LIGHT_CTL This command selects the lighting type on an external light controller board. It allows selection of a lighting configured mode in a UID Verifier multifunction light controller attached to the light controller outputs configured with the SET_CRITERIA command: LIGHT_CTL_BIT_1 LIGHT_CTL_BIT_2 LIGHT_CTL_BIT_3 LIGHT_CTL_BIT_4
Syntax LIGHT_CTL {Light Type} Where: Light Type, Is one of the following: •
Rev 2.4.1, Nov 2008
OFF 90 D 45Q 30T_NS 30T_EW 30Q 30S_N 30S_E 30S_S 30S_W
(90°) (Dome Light) (45° Quad Lights) (30° Two Lights North South) (30° Two Lights East West) (30° Quad Lights) (30° Single Light North) (30° Single Light East) (30° Single Light South) (30° Single Light West)
HawkEye 1500 Reference & Programmers Manual
1-85
1 Remote Commands Reference
LIGHT_CTL
Page 100
Chapter
1
Remote Commands Reference
LOAD This command loads info from a job or PID.
Syntax LOAD {pid# | saved | default} Where: pid#, Load/use decoder settings from a PID. This overwrites all the decoder configurable parameters. Range: 0 - 15, and 99 saved, Load the saved job, and all other system, reporting, communication and application parameters. default, Load factory default settings for a job.
1-86
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov