The text of a manual · part 3 of 28
HawkEye 1500 Series Reference & Programmers Manual, pages 21 to 30
Pages 21 to 30 of 276
The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Microscan HE1510, RVSI CiMatrix HE1510 and Siemens HE1510
Page 21
TABLE 1–4. System Configuration Commands (Continued)
Command
Page
TRIGGER_REDIRECT_EN ABLE
“TRIGGER_REDIRECT_ENABLE” on page 1-182
TRIGTABLE
“TRIGTABLE” on page 1-183
UDP_BROADCAST
“UDP_BROADCAST” on page 1-187
WAVELENGTH
“WAVELENGTH” on page 1-201
TABLE 1–5. Communication Control Related Commands
Command
Page
DHCP
“DHCP” on page 1-51
DOMAIN
“DOMAIN” on page 1-61
EIPENABLE
“EIPENABLE” on page 1-64
INFORM
“INFORM” on page 1-73
IP
“IP” on page 1-78
IPCONFIG
“IPCONFIG” on page 1-79
PROMPT
“PROMPT” on page 1-137
TERMINAL ECHO
“TERMINAL ECHO” on page 1-174
TTY
“TTY” on page 1-186
TABLE 1–6. Decoder Configuration Commands (PID Info)
Command
Page
BARCODE
“BARCODE” on page 1-15
BARCODE ENABLEMASK
“BARCODE ENABLEMASK” on page 1-16
BARCONF
“BARCONF” on page 1-18
BARHGT
“BARHGT” on page 1-19
BARHPS
“BARHPS” on page 1-20
BARLEN
“BARLEN” on page 1-21
BARNUM
“BARNUM” on page 1-22
BARPRB
“BARPRB” on page 1-23
BARQZ
“BARQZ” on page 1-24
BARTHRES
“BARTHRES” on page 1-25
Rev 2.4.1, Nov 2008
HawkEye 1500 Reference & Programmers Manual
1 Remote Commands Reference
Remote Commands
1-7
Page 22
Chapter
1
Remote Commands Reference
TABLE 1–6. Decoder Configuration Commands (PID Info) (Continued)
1-8
Command
Page
BARVPS
“BARVPS” on page 1-26
BARWDT
“BARWDT” on page 1-27
CELL SAMPLE
“CELL SAMPLE” on page 1-40
CELL SIZE
“CELL SIZE” on page 1-41
COLS
“COLS” on page 1-44
ECC
“ECC” on page 1-63
ENSURE
“ENSURE CENTERED” on page 1-65
FINETUNE
“FINETUNE” on page 1-66
HEIGHT
“HEIGHT” on page 1-70
MATCHCOUNT
“MATCHCOUNT” on page 1-94
MATCHSERIAL
“MATCHSERIAL” on page 1-99
MATCHSTRING
“MATCHSTRING” on page 1-100
MORPHOLOGY
“MORPHOLOGY” on page 1-101
NEGATIVE
“NEGATIVE” on page 1-102
NUMBC
“NUMBC” on page 1-104
NUMDM
“NUMDM” on page 1-105
ORIENT
“ORIENT” on page 1-112
POLARITY
“POLARITY” on page 1-132
PROBE
“PROBE DIRECTION” on page 1-134
RATIO
“RATIO” on page 1-142
ROI
“ROI” on page 1-153
ROWS
“ROWS” on page 1-154
STYLE
“STYLE” on page 1-167
THRES
“THRESHOLD” on page 1-175
TIMEOUT
“TIMEOUT” on page 1-177
WARP
“WARP” on page 1-200
WIDTH
“WIDTH” on page 1-202
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov
Page 23
TABLE 1–7. Product Identification (PID) Control Configuration Commands
Command
Page
ASSIGN
“ASSIGN” on page 1-13
ASSIGNEX
“ASSIGNEX” on page 1-14
DELETE
“DELETE” on page 1-50
DIR
“DIR” on page 1-53
LEARN
“LEARN” on page 1-80
LEARNASSIST
“LEARNASSIST” on page 1-82
LEARNCANCEL
“LEARNCANCEL” on page 1-83
LOAD
“LOAD” on page 1-86
PID
“PID” on page 1-130
REMOVE
“REMOVE” on page 1-145
STORE
“STORE” on page 1-166
UNLEARN
“UNLEARN” on page 1-188
VIEW
“VIEW” on page 1-198
TABLE 1–8. Part Queue Configuration/Control Commands
Command
Page
PARTQ
“PARTQ” on page 1-115
PARTQCAPACITY
“PARTQCAPACITY” on page 1-116
PARTQCLEAR
“PARTQCLEAR” on page 1-117
PARTQCOUNT
“PARTQCOUNT” on page 1-118
PARTQFAIL
“PARTQFAIL” on page 1-119
PARTQFTP
“PARTQFTP” on page 1-120
PARTQFTPEX
“PARTQFTPEX” on page 1-122
PARTQREQ
“PARTQREQ” on page 1-123
PARTQREQFORMAT
“PARTQREQFORMAT” on page 1-124
PARTQSAVE
“PARTQSAVE” on page 1-126
PARTQSUM
“PARTQSUM” on page 1-127
Rev 2.4.1, Nov 2008
HawkEye 1500 Reference & Programmers Manual
1-9
1 Remote Commands Reference
Remote Commands
Page 24
Chapter
1
Remote Commands Reference
Command Conventions The following conventions apply to remote command descriptions: •
{ }, Indicates that the information is required.
•
[ ], Indicates that the information is optional.
Terminal Shortcuts TABLE 1–9. Terminal Shortcuts
Shortcut
1-10
What It Does
Ctrl+O
Turn off report output.
Ctrl+P
Toggle the state of the prompt and echo.
Ctrl+Q
Turn off command output.
Ctrl+R
Release control of the unit and put it back online.
Ctrl+S
Take control of the unit and bring it offline (forcibly).
Ctrl+T
Dump the heartbeat string to the terminal.
Ctrl+U
Toggle the display of report strings on the terminal.
Ctrl+W
Turn on command output.
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov
Page 25
Keyword Output Conditions Table 1–10 lists the valid keywords for the listed commands. TABLE 1–10. Keyword Output Conditions
Local Permutations
A N G L E
C H E C K S U M
DECFL
X
D A T A
D A T A H E X
D E T A I L E D
P I D #
T I M E S T A M P
X
X
HEADER
X
X
LOCFL
X
X
V E R I _ 1 _ I A Q G *
V E R I _ D E T A I L
V E R I _ F O R M A T T E D
V E R I _ G R A D E
V E R I _ S T A T U S *
MATCHFL
X
X
X
X
X
X
X
X
X
X
X
X
OKDEC
X
X
X
X
X
X
X
X
X
X
X
X
OKMATCH
X
X
X
X
X
X
X
X
X
X
X
X
RTE
X
X
TRAILER
X
X
Note: You must have a verification license for VERI_1_IAQG and VERI_STATUS.
Rev 2.4.1, Nov 2008
HawkEye 1500 Reference & Programmers Manual
1 Remote Commands Reference
Keyword Output Conditions
1-11
Page 26
Chapter
1
Remote Commands Reference
APERTURE This command sets the synthesized aperture size in mils. It is required for the ISO/IEC 15415 verification process.
Syntax APERTURE {size} Where: size, The synthesized aperture size in mils:
1-12
–
4 - 20
–
AUTO (set to be 80% of grid size); this is the default
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov
Page 27
ASSIGN This command assigns the learned decoder parameters from the indicated PID# to a trigger. When the specified trigger occurs (to initiate the read and decode of an image), the PID parameters are loaded into the decoder while the image is being acquired. This allows multiple learned symbols to be used when online. Note: We recommend you use the ASSIGNEX command in applications instead of ASSIGN, since we will be removing ASSIGN in future versions. See also “LEARN” on page 1-80 and “STORE” on page 1-166.
Syntax ASSIGN {pid} {trig} Where: pid, The product ID number: Range: 1 - 15, 99 (default) trig, The trigger number: Range: 0 - 27
Rev 2.4.1, Nov 2008
HawkEye 1500 Reference & Programmers Manual
1-13
1 Remote Commands Reference
ASSIGN
Page 28
Chapter
1
Remote Commands Reference
ASSIGNEX This command assigns the learned decoder parameters from the indicated PID# to a trigger. When the specified trigger occurs (to initiate the read and decode of an image), the PID parameters are loaded into the decoder while the image is being acquired. This allows multiple learned symbols to be used when online. This command allows the setting of a single trigger. For example: ASSIGNEX 4 {pid} This command allows the inquiry of a single trigger. For example: ASSIGNEX 4 ? Note: See also “LEARN” on page 1-80 and “STORE” on page 1-166.
Syntax ASSIGNEX {trig} {pid} Where: pid, The product ID number: Range: 1 - 15, 99 (default) trig, The trigger number: Range: 0 - 27
1-14
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov
Page 29
BARCODE This command controls all 1-D symbologies except BC412, Postnet, Pharmacode, and QR Code.
Syntax BAR[CODE] {ON | OFF}
Rev 2.4.1, Nov 2008
HawkEye 1500 Reference & Programmers Manual
1 Remote Commands Reference
BARCODE
1-15
Page 30
Chapter
1
Remote Commands Reference
BARCODE ENABLEMASK This command selects a combination of 1-D symbologies.
Syntax BARCODE ENABLEMASK {mask} Where: mask, Is any of the following:
1-16
– bit 0, Code 128
– bit 1, Code 39
– bit 2, Code 93
– bit 3, I2of5
– bit 4, Codabar
– bit 5, UPC EN8
– bit 6, UPC E
– bit 7, UPC Supp
– bit 8, PDF417
– bit 9, BC412
– bit 10, Postnet
– bit 11, Pharmacode
– bit 12, RSS-14
– bit 13, RSS-LIMITED
– bit 14, RSS-EXPANDED
– bit 15, RSS-STACKED
– bit 16, RSS-COMPOSITE
– bit 17, QR-CODE
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov