Page 31

You can turn on individually many barcode types using the following commands: •

BAR128 {? | ON | OFF}

•

BAR25 {? | ON | OFF}

•

BAR39 {? | ON | OFF}

•

BAR412 {? | ON | OFF}

•

BAR93 {? | ON | OFF}

•

BARABAR {? | ON | OFF}

•

BARUPC {? | ON | OFF}

•

BARUPE {? | ON | OFF}

•

BARUPS {? | ON | OFF}

Rev 2.4.1, Nov 2008

HawkEye 1500 Reference & Programmers Manual

1-17

1 Remote Commands Reference

BARCODE ENABLEMASK

Page 32

Chapter

1

Remote Commands Reference

BARCONF This command sets the barcode confidence level. For barcodes that do not use checksum (Code 39, I 2 of 5, Codabar, and BC412), the threshold value can help reduce potential mis-decodes. When the value is raised, a certain number of decodes must agree before the decode is declared successful. On the other hand, if the value is set too high, then a normally decodable but imperfect barcode may not be decoded.

Syntax BARCONF {level} Where: level, Is the confidence level: Range: 0 - 100 Default: 0 (Any possible decode is accepted)

1-18

HawkEye 1500 Reference & Programmers Manual

Rev 2.4.1, Nov

Page 33

BARHGT This command sets the minimum and maximum height of a barcode.

Syntax BARHGT {opt1} {opt2} Where: opt1, Is either of the following: –

MIN (default: 4 pixels)

–

MAX (default: 400 pixels)

opt2, Is the height of the barcode: Range: 4 - 400

Rev 2.4.1, Nov 2008

HawkEye 1500 Reference & Programmers Manual

1 Remote Commands Reference

BARHGT

1-19

Page 34

Chapter

1

Remote Commands Reference

BARHPS This command sets the horizontal probe spacing in pixels. Note: See also “BARVPS” on page 1-26.

Syntax BARHPS {spacing} Where: spacing, Is the horizontal probe spacing: Range: 8 - 256 pixels Default: 16 pixels

1-20

HawkEye 1500 Reference & Programmers Manual

Rev 2.4.1, Nov

Page 35

BARLEN This command sets the minimum and maximum length of a barcode. If barcodes of different type or size need to be decoded, each barcode should be learned separately and the barcode properties recorded by the user. To read them all, the barcode properties list should be manually set to contain all the barcode properties learned from each barcode. Note: See also “BARWDT” on page 1-27.

Syntax BARLEN {opt1} {opt2} Where: opt1, Is either of the following: –

MIN (default: 20 pixels)

–

MAX (default: 600 pixels)

opt2, Is the length of the barcode: Range: 20 - 600

Rev 2.4.1, Nov 2008

HawkEye 1500 Reference & Programmers Manual

1-21

1 Remote Commands Reference

BARLEN

Page 36

Chapter

1

Remote Commands Reference

BARNUM This command sets the minimum and maximum number of barcodes to be decoded.

Syntax BARNUM {opt1} {opt2} Where: opt1, Is either of the following: –

MIN (default: 2)

–

MAX (default: 100)

opt2, Is the number of barcodes to be decoded: Range: 2 - 100

1-22

HawkEye 1500 Reference & Programmers Manual

Rev 2.4.1, Nov

Page 37

BARPRB This command sets the barcode search method.

Syntax BARPRB {method} Where: method, Is one of the following:

Rev 2.4.1, Nov 2008

–

HORI

–

HORI_VERT (default)

–

VERT

–

VERT_HORI

HawkEye 1500 Reference & Programmers Manual

1 Remote Commands Reference

BARPRB

1-23

Page 38

Chapter

1

Remote Commands Reference

BARQZ This command sets the barcode quiet zone length. If for any reason the quiet zone is less in the image due to camera setup restrictions, you can lower the length in order for the algorithm to accept shorter space as quiet zone. On the other hand, if the barcode is big in the FOV such that some space between two adjacent bars exceeds the value specified, then it is possible that this space will be detected as possible quiet zone. To avoid this situation, increase the value of length. Note: Do not adjust this value unless you understand how the change will affect the system performance.

Syntax BARQZ {length} Where: length, Is the quiet zone length: Range: 5 - 100 Default: 12

1-24

HawkEye 1500 Reference & Programmers Manual

Rev 2.4.1, Nov

Page 39

BARTHRES This command sets the barcode threshold out of 255 grayscale.

Syntax BARTHRES {opt} Where: opt, Is the threshold: Range: 5 - 100 grayscale levels Default: 18

Rev 2.4.1, Nov 2008

HawkEye 1500 Reference & Programmers Manual

1 Remote Commands Reference

BARTHRES

1-25

Page 40

Chapter

1

Remote Commands Reference

BARVPS This command sets the vertical probe spacing in pixels. Note: See also “BARHPS” on page 1-20.

Syntax BARVPS {opt} Where: opt, Is the vertical probe spacing: Range: 8 - 256 pixels Default: 16 pixels

1-26

HawkEye 1500 Reference & Programmers Manual

Rev 2.4.1, Nov