Page 11

Contents

Microscan HawkEye™ Reader Object Type Library 2-33 MiCoordinator 2-33 Methods 2-33 Events 2-33 MiDevice 2-34 Methods 2-34 Events 2-36 MiASCIIConnection 2-36 Methods 2-36 MiReportConnection 2-37 Methods 2-37 MiImageConnection 2-37 Methods 2-37 Connection Events 2-38 Events 2-38

Microscan HawkEye™ Reader ActiveX Type Library 2-39 MiTimeplot 2-39 Methods 2-39 MiImageView 2-40 Methods 2-40 Events 2-41 MiDrawObj 2-42 Methods 2-42 MiDC 2-42 Methods 2-42 Pen Style Constants for SetPen 2-43 MiDrawHandles 2-43 Methods 2-44

CHAPTER 3

C++ Samples for TCP/IP Socket Communication 3-1 Example 1 – PartQ Data Retrieval 3-1 Example 2 – Output Socket Data Retrieval

Index

Rev 2.4.1, Nov 2008

3-3

Index-1

HawkEye 1500 Reference & Programmers Manual xi

Page 12

Contents xii

HawkEye 1500 Reference & Programmers Manual

Rev 2.4.1, Nov

Page 13

Preface

Welcome!

PREFACE

Purpose of This Manual This manual describes remote commands and ReadRunner remote libraries.

Manual Conventions The following typographical conventions are used throughout this manual. •

Items emphasizing important information is bolded.

•

Menu selections, menu items and entries in screen images are indicated as: Run (triggered), Modify..., etc.

Rev 2.4.1, Nov 2008

HawkEye 1500 Reference & Programmers Manual xiii

Page 14

Preface xiv

HawkEye 1500 Reference & Programmers Manual

Rev 2.4.1, Nov

Page 15

1 Remote Commands Reference

CHAPTER 1

This chapter lists and describes the HawkEye™ 1500 remote commands. Commands are listed alphabetically.

Basic Operation & Fine Tuning This section describes the basic operations and fine-tuning used with the HawkEye™ 1500.

Command Basics The HawkEye™ 1500 responds to a series of ASCII string commands sent from the host computer over RS-232 and Ethernet ports. Each command must follow the designated command syntax for the camera to respond successfully. The command sequence consists of the command word(s) followed by any additional keyword or parameters required, and terminated with a carriage return <CR> or <Enter>.

Action Commands Action commands cause an action to take place. They have no settings that can be queried by the user. For example, the SAVE command is an action command that initiates the action of saving system parameters to the FLASH storage system on the camera. There is nothing to query about SAVE.

Rev 2.4.1, Nov 2008

HawkEye 1500 Reference & Programmers Manual

1-1

Remote Commands Reference

1

Page 16

Chapter

1

Remote Commands Reference

Configuration Commands Configuration commands “set” a parameter or “query” the contents of a parameter. For example, the ROWS command sets the number of rows to a specific number. All configuration commands follow the same syntax and format: •

A configuration command followed by a “?” means query the current value (return to the user the current value of the configuration command). For example: ROWS ?

Would result in the following: ROWS AUTO •

(or whatever the current value is at that time)

A configuration command followed by a blank (no parameter) means show the user a quick 'help' on the command syntax. For example: ROWS <ENTER>

Would result in the following: ROWS {rows|AUTO}, Set the number of rows to expected: 8-144, AUTO=default •

A configuration command followed by 'DEF[AULT]' means set the current value of the command to its default value. The default value being the value that was initially set from the Factory Default configuration. For example: ROWS DEF[AULT]

Would result in the current value of ROWS to be set to its default value of AUTO. To get help on a particular Action command, you would issue the word “HELP” followed by the command of interest. For example:

1-2

HawkEye 1500 Reference & Programmers Manual

Rev 2.4.1, Nov

Page 17

HELP RESET

Would result in the following: RESET [opt] - Reset the unit - Reset user settings type Help Reset v[erbose] If more detailed help information is desired (and available), issue: HELP RESET V[erbose]

Which would result in printing more verbose help information. RESET [opt] - Reset the unit - Reset user settings type Help Reset v[erbose] RESET FACTORY - Reset all settings to factory defaults. This includes all connectivity options. The camera will be set to DHCP Y, camera name 'HawkEye', default IP address, CONSOLE 0, BEEP Y. Essentially, all decoder parameters, acquisition parameters, and BOOTPARAMS stuff (except for the MAC address) would be reset to factory defaults. All would be saved to flash. RESET DECODER - This would be the same as LOAD 99 and would reset the decoder (only) to defaults. Photometry would also be reset to Auto. This would save to flash, whereas LOAD 99 would not. RESET APPMODE - This would reset the acquisition parameters and lighting (essentially everything in the Application Mode dialog of RR. This would save to flash. RESET HARD - This reboots the unit. RESET SOFT - This goes offline, restores the registry to factory default, and goes back online. RESET ALL - This does a 'reset factory', saves to flash, and 'reset hard'. For the most part, commands are NOT case sensitive. When entering strings (as required by a particular command), the string must be entered in quotes. Characters in quotes are case sensitive. You get what you type.

Getting Help on a Particular Command If you are not using ReadRunner to control the camera or, if you are and wish to command the camera via the Command Terminal Window, the following describes the available options:

Rev 2.4.1, Nov 2008

HawkEye 1500 Reference & Programmers Manual

1-3

1 Remote Commands Reference

Basic Operation & Fine Tuning

Page 18

Chapter

1

Remote Commands Reference

HELP <ENTER>

Displays a listing of all the available commands divided into eight categories. Once you see the command that is most likely the one of interest, you can get quick help by typing: HELP {command} or verbose help on the command by typing: HELP {command} V[erbose]

Additionally, you can get help on configuration commands by typing the command with no parameter information provided. For example: HELP ROWS <ENTER>

Would result in the following: ROWS {rows|AUTO} - Set the number of rows to expected: 8-144, AUTO=default

Remote Commands Table 1–1 through Table 1–8 group commands based on function. TABLE 1–1. Housekeeping Query Commands

1-4

Command

Page

HELP

“HELP” on page 1-71

QUICSET

“QUICSET” on page 1-139

SHOW

“SHOW” on page 1-163

STATS

“STATS” on page 1-165

VERSION

“VERSION” on page 1-196

HawkEye 1500 Reference & Programmers Manual

Rev 2.4.1, Nov

Page 19

TABLE 1–2. System Operation Control Commands

Command

Page

CAPTURE

“CAPTURE” on page 1-39

CONTROL

“CONTROL” on page 1-48

OFFLINE

“OFFLINE” on page 1-106

ONLINE

“ONLINE” on page 1-111

RELEASE

“RELEASE” on page 1-144

RESET

“RESET” on page 1-148

RUN_SETTINGS

“RUN_SETTINGS” on page 1-156

SAVE

“SAVE” on page 1-158

VT

“VT” on page 1-199

TABLE 1–3. Serial Reporting Configuration Commands

Command

Page

DECFL

“DECFL” on page 1-49

HEADER

“HEADER” on page 1-69

IOASSIGN

“IOASSIGN” on page 1-76

LOCFL

“LOCFL” on page 1-87

MATCH_LIST

“MATCH_LIST” on page 1-91

MATCH_LIST_ENABLE

“MATCH_LIST_ENABLE” on page 1-93

MATCHFL

“MATCHFL” on page 1-97

OKDEC

“OKDEC” on page 1-107

OKMATCH

“OKMATCH” on page 1-109

OUTPUT

“OUTPUT” on page 1-113

RTE

“RTE” on page 1-155

SET_CRITERIA

“SET_CRITERIA” on page 1-160

TRAILER

“TRAILER” on page 1-179

VERENABLE

“VERENABLE” on page 1-189

VERIFY

“VERIFY” on page 1-192

VERIFY AIMDPM

“VERIFY AIMDPM” on page 1-195

VERSTATUS

“VERSTATUS” on page 1-197

Rev 2.4.1, Nov 2008

HawkEye 1500 Reference & Programmers Manual

1 Remote Commands Reference

Remote Commands

1-5

Page 20

Chapter

1

Remote Commands Reference

TABLE 1–4. System Configuration Commands

1-6

Command

Page

APERTURE

“APERTURE” on page 1-12

CAL_MEAN_LIGHT

“CAL_MEAN_LIGHT” on page 1-38

CALIBRATED

“CALIBRATED” on page 1-36

CALIBRATED_STRING

“CALIBRATED_STRING” on page 1-37

CELL_UNIT

“CELL_UNIT” on page 1-42

CELL_UNIT_REPORT

“CELL_UNIT_REPORT” on page 1-43

CONTRAST

“CONTRAST” on page 1-46

CONTRAST_REPORT

“CONTRAST_REPORT” on page 1-47

DWELLTIME

“DWELLTIME” on page 1-62

ILLUMINATION

“ILLUMINATION” on page 1-72

IO_MODE

“IO_MODE” on page 1-75

LIGHT_CTL

“LIGHT_CTL” on page 1-85

MATCH

“MATCH” on page 1-89

MATCHEX

“MATCHEX” on page 1-95

PHOTOMETRY

“PHOTOMETRY” on page 1-129

QUICSETPLUS

“QUICSETPLUS” on page 1-141

RETRY

“RETRY” on page 1-149

SELF_TRIGGER

“SELF_TRIGGER” on page 1-159

SIGOUT

“SIGOUT” on page 1-164

TARGET

“TARGET” on page 1-168

TARGET_CALIB_CONTRA ST

“TARGET_CALIB_CONTRAST” on page 1-169

TARGET_CALIB_REFLECT ANCE

“TARGET_CALIB_REFLECTANCE” on page 1-170

TBL

“TBL” on page 1-171

TD

“TD” on page 1-172

TE

“TE” on page 1-173

TRIG

“TRIG{GER}” on page 1-181

HawkEye 1500 Reference & Programmers Manual

Rev 2.4.1, Nov