Page 181

STYLE

1

This command selects whether the Data Matrix symbol is viewed as if through a mirror or direct.

Remote Commands Reference

STYLE

Syntax STYLE {style} Where: style, Is one of the following:

Rev 2.4.1, Nov 2008

–

AUTO

–

MIRROR

–

NORMAL (default)

HawkEye 1500 Reference & Programmers Manual

1-167

Page 182

Chapter

1

Remote Commands Reference

TARGET This command turns the Target Laser on or off.

Syntax TARGET {opt} Where: opt, Is either of the following:

1-168

–

ON (default)

–

OFF

–

T, Turn on laser for two seconds after acquisition.

HawkEye 1500 Reference & Programmers Manual

Rev 2.4.1, Nov

Page 183

TARGET_CALIB_CONTRAST This command sets the calibration target contrast value.

Syntax TARGET_CALIB_CONTRAST {value} Where: value, 50 - 100 (default = 80)

Rev 2.4.1, Nov 2008

HawkEye 1500 Reference & Programmers Manual

1 Remote Commands Reference

TARGET_CALIB_CONTRAST

1-169

Page 184

Chapter

1

Remote Commands Reference

TARGET_CALIB_REFLECTANCE This command sets the calibration target reflectance value.

Syntax TARGET_CALIB_REFLECTANCE {value} Where: value, 50 - 100 (default = 90)

1-170

HawkEye 1500 Reference & Programmers Manual

Rev 2.4.1, Nov

Page 185

TBL This command sets the opto isolated input trigger’s bounce latch time. Note: See also “TD” on page 1-172 and “TE” on page 1-173.

Syntax TBL {time} Where: time, Is the bounce latch time: Range: 0 - 10000ms Default: 20ms

Rev 2.4.1, Nov 2008

HawkEye 1500 Reference & Programmers Manual

1 Remote Commands Reference

TBL

1-171

Page 186

Chapter

1

Remote Commands Reference

TD This command sets the opto isolated input trigger’s interrupt detection delay. Note: See also “TBL” on page 1-171 also “TE” on page 1-173.

Syntax TD {delay} Where: delay, Is the delay: Range: 0 - 10000ms Default: 0ms

1-172

HawkEye 1500 Reference & Programmers Manual

Rev 2.4.1, Nov

Page 187

TE This command sets the opto isolated input trigger’s edge direction. Note: See also “TBL” on page 1-171 and “TD” on page 1-172.

Syntax TE {direction} Where: direction, Is one of the following:

Rev 2.4.1, Nov 2008

–

B, Both

–

N, Negative (default)

–

P, Positive

HawkEye 1500 Reference & Programmers Manual

1 Remote Commands Reference

TE

1-173

Page 188

Chapter

1

Remote Commands Reference

TERMINAL ECHO This command enables/disables echoing of typed data.

Syntax TERMINAL ECHO {opt} Where: opt, Is either of the following:

1-174

–

ON

–

OFF (default)

HawkEye 1500 Reference & Programmers Manual

Rev 2.4.1, Nov

Page 189

THRESHOLD This command selects the threshold method in binarizing.

Syntax THRES[HOLD] {opt} Where: opt, Is one of the following methods: –

GLOBAL, Should always be used unless it produces excessive SYMBOL_UNDECODABLE

–

LOCAL, Effective if Data Matrix cells are not printed with equal space

–

ADAPTIVE, Effective when the Data Matrix area has uneven background

The default is: THRES:Global, Local, Adaptive or Global+Local+Adaptive

Rev 2.4.1, Nov 2008

HawkEye 1500 Reference & Programmers Manual

1 Remote Commands Reference

THRESHOLD

1-175

Page 190

Chapter

1

Remote Commands Reference

TIME This command displays current time in the unit.

Syntax •

Display the current time in hex: TIME ?

•

Display the current time in seconds, since THU JAN 01 00:00:00 1970. This message sets the time in the HawkEye™ 1500 for time stamping of images: TIME

1-176

HawkEye 1500 Reference & Programmers Manual

Rev 2.4.1, Nov