Page 191

TIMEOUT

1

This command limits the time spent in the algorithm trying to inspect/decode the symbol just lifted.

Remote Commands Reference

TIMEOUT

Caution: Only an Applications Engineer trained in systems use should change this parameter. Another method to limit the time spent in the algorithm is to turn off all 2-D symbologies if the parts being read are always 1-D.

Syntax TIMEOUT {READ | EDAC} Where: READ, 0 - 9999ms; default is 600ms EDAC, 0 - 9999ms; default is 45ms

Rev 2.4.1, Nov 2008

HawkEye 1500 Reference & Programmers Manual

1-177

Page 192

Chapter

1

Remote Commands Reference

TIMESYNC This command uses the SNTP server to synchronize local time on the camera (per RFC 868).

Syntax TIMESYNC {interval} [server] Where: interval, Interval (in seconds) to query for time server, Name of time server

1-178

HawkEye 1500 Reference & Programmers Manual

Rev 2.4.1, Nov

Page 193

TRAILER This command sets the Report Trailer to the indicated string. Use TRAILER to “follow” the decode output with text. For example, to prompt the user for the next read: TRAILER “Next item:” The fourth option of the following commands determines whether or not the trailer is printed: •

BATCHFL

•

DECFL

•

LOCFL

•

MATCHFL

•

OKDEC

•

OKMATCH

•

RTE

Syntax TRAILER {string} Where: string, (1 to 80 characters); the string may include control characters by preceding the control char with ’\’, and followed by two hex characters. For example: ""\07"" for bell ""\\"" for a backslash character The string may include keyword substitution: –

Rev 2.4.1, Nov 2008

CHECKSUM, This keyword expands to the checksum of the characters in the appropriate Output Format String where the (CHECKSUM) keyword is inserted. The two character ASCII value representation of the Hexadecimal checksum (for example, 2E) is substituted in the Output string. The checksum is calculated as the

HawkEye 1500 Reference & Programmers Manual

1-179

1 Remote Commands Reference

TRAILER

Page 194

Chapter

1

Remote Commands Reference

Exclusive OR (XOR) of all the characters up to the (CHECKSUM) keyword, including the Header and the Trailer characters if (CHECKSUM) is placed at the end of the trailer string. –

1-180

TIMESTAMP, This keyword will be substituted with the current date and time.

HawkEye 1500 Reference & Programmers Manual

Rev 2.4.1, Nov

Page 195

TRIG{GER} This command sets the triggering mode of the HawkEye™ 1500.

Syntax •

Set triggering mode to continuous read: TRIG C

•

Set triggering mode to read only when triggered: TRIG T

•

Enter a character string to signal a virtual trigger: TRIG U <chars> Where: chars, Is the set of printable characters to be used as the virtual trigger. You can define up to five printable characters. This “string” trigger can be sent over serial or the ASCII PLC TCP/IP connection port. Note: TRIG U with no string specified sets the trigger string to a space character “ “. This is the default trigger character.

Rev 2.4.1, Nov 2008

HawkEye 1500 Reference & Programmers Manual

1 Remote Commands Reference

TRIG{GER}

1-181

Page 196

Chapter

1

Remote Commands Reference

TRIGGER_REDIRECT_ENABLE This command controls whether or not the physical trigger will be redirected to the application in the form of an empty cycle report instead of performing the trigger. This allows the application to decide if it is an appropriate time to perform the trigger by either throwing away the cycle report or sending a VT command back to the camera.

Syntax TRIGGER_REDIRECT_ENABLE {ON | OFF=default}

1-182

HawkEye 1500 Reference & Programmers Manual

Rev 2.4.1, Nov

Page 197

TRIGTABLE This command alters the dynamics of hardware lines, and configures virtual triggers. Note: I/O management of Physical INPUT and OUTPUT lines is now done with SET_CRITERIA and IOASSIGN commands. To prevent the TRIGTABLE commands from causing conflicts, TRIGTABLE is no longer allowed to work on trigger numbers 3, 4, 5, and 6. To alter the dynamics of an actual hardware line: •

Any hardware line that can cause an interrupt (including the QuicSet® button) can have the polarity, latch and delay modified using the TRIGTABLE command. Use the following trigger number on the HawkEye™ 1500: –

•

2, Opto Isolated Trigger Input

There are also several GP outputs that indicate read results. These are marked as outputs. The Edge options on these outputs are valid only for those outputs and have no effect on inputs since they are virtual. Use the following trigger numbers on the HawkEye™ 1500 to affect just the output edges: –

12, Opto Isolated Output 1

–

13, Opto Isolated Output 2

–

14, Opto Isolated Output 3

–

16, General Purpose Output 2

–

17, General Purpose Output 3

–

18, General Purpose Output 4

To program the functionality of a physical or virtual trigger: •

Rev 2.4.1, Nov 2008

Each of the 28 triggers can trigger the unit. The Opto Isolated trigger is automatically wired into the unit and will be used primarily to cause physical trigger inputs to the system.

HawkEye 1500 Reference & Programmers Manual

1-183

1 Remote Commands Reference

TRIGTABLE

Page 198

Chapter

1

Remote Commands Reference

•

The General Purpose inputs can be wired to the external connector (see the HawkEye™ 1500 Series User Manual) to also cause real interrupts. All of the other trigger numbers can be used as virtual triggers. The user or GUI simply needs to send the command “VT #” and the unit will respond as though an actual interrupt occurred.

Syntax •

Enable or disable the following triggers for initiating a Decode sequence: TRIGTABLE {opt1} {opt2} Where: opt1, 0 - 27 or GPIO opt2, Is either ENABLE or DISABLE If GPIO is enabled, then when an Opto Isolated Sensor Input trigger occurs, the three GPIO input lines 2, 3, 4 are read to determine a VT # to occur.

•

Set trigger latch time (debounce) in milliseconds: TRIGTABLE {opt1} LATCH {opt3} Where: opt1, Is the trigger number (2, 9) opt3, Is the time in milliseconds (0 - 1000)

•

Set delay from trigger to recognition of trigger in milliseconds: TRIGTABLE {opt1} DELAY {opt3} Where: opt1, Is the trigger number (2, 9) opt3, Is the time in milliseconds (0 - 1000)

•

Set trigger edge detection Positive or Negative: TRIGTABLE {opt1} EDGE {opt3} Where:

1-184

HawkEye 1500 Reference & Programmers Manual

Rev 2.4.1, Nov

Page 199

opt1, Is the trigger number (2, 9) opt3, Is the edge (POSITIVE or NEGATIVE) •

Set the functionality of the trigger to be a Read or Learn: TRIGTABLE {opt1} {opt2} Where: opt1, Is the trigger number (0 - 27) opt2, Is either READ (default) or LEARN

Rev 2.4.1, Nov 2008

HawkEye 1500 Reference & Programmers Manual

1 Remote Commands Reference

TRIGTABLE

1-185

Page 200

Chapter

1

Remote Commands Reference

TTY This command sets multiple TTY settings.

Syntax TTY [baud] [parity] [databits] [stopbits] [flowcontrol] Where: Baud, 600 - 256000bps parity, O or E or None databits, 7 or 8 stopbits, 1 or 2 flowcontrol, Is one of the following:

1-186

–

N, None

–

H, Hardware

–

X, XonXoff

HawkEye 1500 Reference & Programmers Manual

Rev 2.4.1, Nov