Page 171
FIGURE 1–1. Settings Window
RUN_SETTINGS FACTORY restores these settings
RUN_SETTINGS BOTH restores these settings
RUN_SETTINGS CUSTOMER restores these settings
•
Hardware Settings Installed in Manufacturing, These settings depend on the hardware purchased by the customer.
•
Customer Settings Installed in Manufacturing, These settings depend on the customer’s specifications.
•
Manufacturing Data, These are such things as MAC address, serial numbers, and so on.
Rev 2.4.1, Nov 2008
HawkEye 1500 Reference & Programmers Manual
1 Remote Commands Reference
RUN_SETTINGS
1-157
Page 172
Chapter
1
Remote Commands Reference
SAVE This command saves the current configuration (regardless of boot option).
Syntax SAVE {opt} Where: opt, Is either of the following:
1-158
–
BOOT, Load the job on boot. This is the default.
–
NOBOOT, Clear the BOOT option.
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov
Page 173
SELF_TRIGGER This command generates periodic virtual triggers. Enabling SELF_TRIGGERing allows continuous triggering at a fixed interval without requiring external hardware. Motion and Stop-and-Scan application modes are the typical use for this command. A <duration> of 0 disables the SELF_TRIGGERing.
Syntax SELF_TRIGGER {virtual trigger number} {duration} Where: Virtual trigger number, 0 - 27 duration, 0 - 30,000ms (default = 0)
Rev 2.4.1, Nov 2008
HawkEye 1500 Reference & Programmers Manual
1-159
1 Remote Commands Reference
SELF_TRIGGER
Page 174
Chapter
1
Remote Commands Reference
SET_CRITERIA This command allows criteria for variable testing to be configured for the IOASSIGN command.
Syntax SET_CRITERIA {variable_name} {Type} {arg1} {arg2} Where: variable_name, The supported variable_names are: –
ANGLE_FAILURE
–
LOCATE_FAILURE
–
DECODE_FAILURE
–
RTE
–
PASS
–
FAIL
–
DV
–
GOOD (reserved for verification option)
–
FAIR (reserved for verification option)
–
POOR (reserved for verification option)
–
EXPRESSION1 (reserved for future use)
–
EXPRESSION2 (reserved for future use)
Type, The supported Types are: –
BOOL No arguments required The contents of the variable_name is a Boolean data type determines ON/OFF states.
–
1-160
MASK
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov
Page 175
arg1, bit_mask entered as a hex value like 0x200 arg2 is not required The contents of the variable_name will be ANDed with the argument value to isolate a bit in a value; in other words, a particular bit in an error code could be used to trigger a digital output. –
NOMINAL_DEV arg1, a nominal value arg2, deviation from the nominal value This tests the contents of a variable name to see if it is in the range of “Nominal +/- Deviation.” Use this type with ANGLE_FAILURE as 0° +/- 10° will be translated correctly, while MAX_MIN will reject any entered Minimum greater than the entered Maximum.
–
MAX_MIN arg1, maximum value arg2, minimum value This tests the contents of a variable name to see if “Minimum < value < Maximum.”
INPUT_POS, Trigger edge directions INPUT_NEG INPUT_BOTH For the 3 Input Types: arg1, The delay (0 - 10000ms) before performing the trigger. arg2, The latch time (0 - 10000ms) to wait for the line to become stable. –
EXPR, (Reserved for future use)
Note: Only integer value are supported.
Rev 2.4.1, Nov 2008
HawkEye 1500 Reference & Programmers Manual
1-161
1 Remote Commands Reference
SET_CRITERIA
Page 176
Chapter
1
Remote Commands Reference
SET_LICENSE This command allows you to enter manually a license key to enable Options. Note: Licenses only activate the desired Option on the camera for which it was issued. Double check that the Serial Numbers match. For example: SET_LICENSE D8R3Z-6UUV4-3SXTM-K7LB6-D5GT9
Syntax SET_LICENSE {key string}
1-162
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov
Page 177
SHOW This command shows a group of current settings based on category.
Syntax •
Show current values of all commands in a job: SHOW ALL
•
Show current values of specific commands in a specific job: SHOW {cat} {job} Where: cat, 3, Serial Reporting commands 4, System Configuration commands 5, Communication Related commands job, 0, Current settings (default) 1, Saved job 99, Factory defaults.
•
Show current values of commands in a PID: SHOW {cat} [pid]
Rev 2.4.1, Nov 2008 cat, 6, Fine Tuning Symbology/Decoder pid, 0 - 15, 99
HawkEye 1500 Reference & Programmers Manual
1 Remote Commands Reference
SHOW
1-163
Page 178
Chapter
1
Remote Commands Reference
SIGOUT This command sets the polarity for the I/O lines.
Syntax SIGOUT {name} {level} Where: name, Is one of the following: –
OPTO_OUT1
–
OPTO_OUT2
–
OPTO_OUT3
–
GPIO_OUT1
–
GPIO_OUT2
–
GPIO_OUT3
–
GPIO_OUT4 level, Is the level:
1-164
–
H, high
–
L, low
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov
Page 179
STATS This command tracks reading statistics.
Syntax •
Display the current statistics (this is the default): STATS ?
•
Reset the statistics: STATS RESET
Rev 2.4.1, Nov 2008
HawkEye 1500 Reference & Programmers Manual
1 Remote Commands Reference
STATS
1-165
Page 180
Chapter
1
Remote Commands Reference
STORE This command stores all parameters associated with decoding a symbol. The STORE command can store up to 15 learned symbols. Note: You must issue the SAVE command to store all 15 PIDs to Flash. The STORE command overwrites any saved parameters previously saved with the STORE command.
Syntax STORE {pid#} Where: pid#, Is the PID number: Range: 1 - 15
1-166
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov