Page 161

REPORTREQ This command retrieves the next report from the system while running. This command is only used by ReadRunner.

Syntax REPORTREQ {opt1} {opt2} {opt3} Where: opt1, Compression 0, Lossless compression NOT IMPLEMENTED 1, JPEG with quality value=1, 4:1 compression ratio 4, JPEG with quality value=4, 8:1 compression ratio 26, Decimated image with JPEG quality=2, 16:1 compression ratio 27, Decimated image with JPEG quality=5, 32:1 compression ratio 255, No compression applies; image uploaded in full NONE, No compression applies; image uploaded in full (DEFAULT) opt2, Is either 0 (keep image out) or 1 (include image) opt3, NEXTFAIL or LASTFAIL, Retrieves the next failed or last failed report. If not specified, retrieves the next report.

Rev 2.4.1, Nov 2008

HawkEye 1500 Reference & Programmers Manual

1-147

1 Remote Commands Reference

REPORTREQ

Page 162

Chapter

1

Remote Commands Reference

RESET This command resets some or all settings and, in some cases, reboots the unit.

Syntax RESET [opt] Where: opt, Is one of the following:

1-148

–

ALL, Performs a RESET FACTORY, saves it to Flash, and then reboots the unit.

–

APPMODE, Reset the acquisition parameters and lighting (essentially everything in the Application Mode dialog of ReadRunner) and save it to flash.

–

DECODER, Reset the decoder to factory defaults, reset photometry to Auto, and save it to flash.

–

HARD, Reboot the unit.

–

FACTORY, Reset all settings to factory defaults. This includes all connectivity options. The camera will be set to DHCP Y, the camera name will be set to “HawkEye” (where xxyyzz are the last three octets of the camera’s MAC address), default IP address, CONSOLE 0, BEEP Y. All decoder parameters, acquisition parameters, and BOOT PARA MS (except for the MAC address) will be set to factory defaults. All will be save to flash.

–

SOFT, This takes the camera offline (if necessary), performs the equivalent of RESET APPMODE and RESET DECODER, removes any saves PIDs as seen with the DIR command, and then restores the starting offline status. No changes are made to the BOOT PARAMS and the camera is not rebooted.

HawkEye 1500 Reference & Programmers Manual

Rev 2.4.1, Nov

Page 163

RETRY This command sets the retry mode, which allows the reader to try different decoder or light parameters, as well as to try multiple image captures.

Syntax •

Set read cycle to single attempt mode with no retries on failure. This is the default: RETRY NONE

•

Set read cycle to multiple retry attempts within the specified time limit: RETRY TIME opt Where: opt, Is 35 - 60000ms

•

Set read cycle to a specified number of attempts: RETRY COUNT opt Where: opt, Is 1 - 15

•

Report only successful attempts. If duplicate data occurs, report it only if opt ms have elapsed since last decode: RETRY SUPERMARKET opt Where: opt, Is 0 - 60000ms; (0 = infinite ISWT)

•

While the GPIO signal is present on Pin 9, keep retrying: RETRY GPIO

•

Rev 2.4.1, Nov 2008

Retry up to three PIDs if the first decode failed. You may define a list of up to three PIDs to be tried on decode failure. The decode occurs on the same image. The last PID used will be left as the current PID unless there is a PID assigned to the trigger and, if so, the PID assigned to the trigger will be the next loaded and used:

HawkEye 1500 Reference & Programmers Manual

1-149

1 Remote Commands Reference

RETRY

Page 164

Chapter

1

Remote Commands Reference

RETRY LIST [pid# | pid# | pid#] Where: pid#, Is the PID number. •

Retry once using the specified lighting: RETRY LIGHT {opt} {pid} Where: opt, Is one of the following: •

OFF, Use ambient lighting.

•

ON, Use constant lighting; this is the default.

•

EXTERNAL, Use external lighting.

•

STROBE, Use strobe lighting.

•

POWER[_STROBE], Use power stobed lighting.

•

ON_AND_PSTROBED, Constant on with power strobing at trigger.

pid, You may define a valid PID to be tried on decode failure. The gain and exposure from the indicated PID will be used only if the Photometry is set. This mode is used commonly with the internal lighting provided and on retry using an external light (user provided) usually with Dot Peen marks.

1-150

HawkEye 1500 Reference & Programmers Manual

Rev 2.4.1, Nov

Page 165

RETRYEX This command sets the retry modes of the system for all modes. It is identical to the RETRY command; however, it is meant to be used by custom FBI or C++ code and requires all fields to be specified. In addition, RETRYEX can be queried. ReadRunner uses RETRYEX to program all the retry modes in the camera. RETRY is meant to be used instead by a user typing the command manually in the Terminal Window or Hypercritical program. Note: Each field must contain valid information regardless of the mode.

Syntax •

Set read cycle to single attempt mode with no retries on failure. This is the default: RETRY NONE

•

Set read cycle to multiple attempts within the specified time limit: RETRY TIME opt Where: opt, Is 35 - 60000ms

•

Set read cycle to a specified number of attempts: RETRY COUNT opt Where: opt, Is 1 - 15

•

Report only successful attempts. If duplicate data occurs, report it only if opt ms have elapsed since last decode: RETRY SUPERMARKET opt Where: opt, Is 35 - 60000ms

•

Rev 2.4.1, Nov 2008

While the GPIO signal is present on Pin 9, keep retrying:

HawkEye 1500 Reference & Programmers Manual

1-151

1 Remote Commands Reference

RETRYEX

Page 166

Chapter

1

Remote Commands Reference

RETRY GPIO •

Retry up to three PIDs if the first decode failed. You may define a list of up to three PIDs to be tried on decode failure. The decode occurs on the same image. The last PID used will be left as the current PID unless there is a PID assigned to the trigger and, if so, the PID assigned to the trigger will be the next loaded and used: RETRY LIST [pid# | pid# | pid#] Where: pid#, Is the PID number.

•

Retry once using the specified lighting: RETRY LIGHT {opt} {pid} Where: opt, Is one of the following: •

OFF, Use ambient lighting.

•

ON, Use constant lighting; this is the default.

•

EXTERNAL, Use external lighting.

•

STROBE, Use strobe lighting.

•

POWER[_STROBE], Use power stobed lighting.

•

ON_AND_PSTROBED, Constant on with power strobing at trigger.

pid, You may define a valid PID to be tried on decode failure. The gain and exposure from the indicated PID will be used only if the Photometry is set. This mode is used commonly with the internal lighting provided and on retry using an external light (user provided), usually with Dot Peen marks.

1-152

HawkEye 1500 Reference & Programmers Manual

Rev 2.4.1, Nov

Page 167

ROI This command defines the region of interest (ROI) for the symbol.

Syntax •

Define the coordinates of the region of interest: ROI {ux, uy, lx, ly} Where:

•

– ux, 0 - 658 (658 = default); u corresponds to upper left

– uy, 0 - 493 (493 = default); u corresponds to upper left

– lx, 0 - 658 (0 = default); l corresponds to lower right

– ly, 0 - 493 (0 = default); 1 corresponds to lower right

Define the region of interest based on the most recently decoded Data Matrix: ROI AUTO {pad} Where: pad, Is one of the following:

•

–

1, 50 pixels larger than the Data Matrix

–

2, 100 pixels larger than the Data Matrix

–

3, 150 pixels larger than the Data Matrix

–

4, 200 pixels larger than the Data Matrix

Reset the region of interest back to the original area (full ROI): ROI RESET

Rev 2.4.1, Nov 2008

HawkEye 1500 Reference & Programmers Manual

1 Remote Commands Reference

ROI

1-153

Page 168

Chapter

1

Remote Commands Reference

ROWS This command specifies the number of rows to expect in the Data Matrix symbol. The algorithm uses the value specified without having to re-compute it from image to image. Note: See also “COLS” on page 1-44.

Syntax ROWS {opt} Where: opt, Is either of the following: – rows, Is the number of rows: Range: 8 - 144

–

1-154

AUTO, Autoselect (default)

HawkEye 1500 Reference & Programmers Manual

Rev 2.4.1, Nov

Page 169

RTE This command customizes the overrun message output of the HawkEye™ 1500. This command only affects the STANDARD output. See “OUTPUT” on page 1-113 for more details.

Syntax RTE {cntrl} [""string""] [{Hdrcntrl} {Trlcntrl} {Beepcntrl}] Where: cntrl, Is the RTE message active (Y or N)? string, (1 - 39 characters); the string may include keyword substitution: –

CHECKSUM, This keyword expands to the checksum of the characters in the appropriate Output Format String where the (CHECKSUM) keyword is inserted. The two character ASCII value representation of the Hexadecimal checksum (for example, 2E) is substituted in the Output string. The checksum is calculated as the Exclusive OR (XOR) of all the characters up to the (CHECKSUM) keyword, including the Header and the Trailer characters if (CHECKSUM) is placed at the end of the trailer string.

–

TIMESTAMP, This keyword will be substituted with the current date and time.

Note: The following parameters are optional. However, it you enter one of them, you must enter all of them at the same time. Hdrcntrl, Print the header before the RTE string (Y or N)? Trlcntrl, Print the trailer before the RTE string (Y or N)? Beepcntrl, Sound this many beeps (0 - 3) when this report is issued. The default is 0.

Rev 2.4.1, Nov 2008

HawkEye 1500 Reference & Programmers Manual

1-155

1 Remote Commands Reference

RTE

Page 170

Chapter

1

Remote Commands Reference

RUN_SETTINGS This command runs the factory set commands without resetting customer tuning.

Syntax RUN_SETTINGS {opt} Where: opt, Is one of the following: –

BOTH, Run the factory installed command sequences seen in the Hardware Settings and Customer Settings of the Settings window.

–

CUSTOMER, Run the factory installed command sequences seen in the Customer Settings of the Settings window.

–

FACTORY, Run the factory installed command sequences seen in the Hardware Settings of the Settings window.

Displaying the Settings Window Use the following procedure to display the Settings window: 1.

In ReadRunner, click Add Camera.

2.

Highlight a camera name and click OK.

3.

Click (to select) the camera button for the camera you just added.

4.

From the Help menu, click About ReadRunner.

5.

Click Details. ReadRunner displays a screen similar to the one in Figure 1–1.

1-156

HawkEye 1500 Reference & Programmers Manual

Rev 2.4.1, Nov