Page 151
PROMPT This command controls the user-defined command prompt.
Syntax PROMPT {opt} [""prompt string""] Where: opt, Is either of the following: ON OFF (default) prompt string, Up to a 40-character prompt string. The default is > . The string may include control characters by preceding the control char with ’\’, and followed by two hex characters. For example: ""\07"" for bell ""\\"" for a backslash character
Rev 2.4.1, Nov 2008
HawkEye 1500 Reference & Programmers Manual
1 Remote Commands Reference
PROMPT
1-137
Page 152
Chapter
1
Remote Commands Reference
QRFINDER This command sets the QR finder misalignment parameter.
Syntax QRFINDER {opt} Where: opt, Is one of the following:
1-138
–
0, QR_FINDER_SHIFT_NONE (default)
–
1, QR_FINDER_SHIFT_IN1
–
2, QR_FINDER_SHIFT_IN2
–
3, QR_FINDER_SHIFT_IN3
–
4, QR_FINDER_SHIFT_OUT1
–
5, QR_FINDER_SHIFT_OUT2
–
6, QR_FINDER_SHIFT_OUT3
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov
Page 153
QUICSET QuicSet® provides audible and visual feedback about the optical alignment of the camera and the symbol positioned under it. QuicSet® also determines the correct Gain and Exposure settings for the symbol. To enter QuicSet® mode, press the recessed QuicSet button once. Note: The QuicSet® button is located on the connector side of the camera, which is opposite the lens side. You will need a paper clip. The yellow Mode LED should start flashing. Physically position the camera above the symbol. You will hear a series of beeps. The beeps have three tones: •
Lowest Tone, Symbol is in the field of view
•
Middle Tone, Symbol is close to being in the optimal read position
•
Highest Tone, Symbol is in optimal read position
The LEDs on the front of the camera illuminate to indicate positioning: •
All LEDs on, Optimal setting
•
Mode LED flashing, Poor symbol alignment
Move the camera until you hear the highest tone, and then lock down the camera. To exit QuicSet®, press the QuicSet button once. You should hear three short beeps, and the Mode light should be steady on, indicating that the camera has stored the Gain and Exposure parameters. The camera is now online, running an application. The QuicSet® feature is effective only if Photometry is set to manual. You can initiate the LEARN and UNLEARN commands using the QuicSet button. In the Terminal window, type HELP LEARN V or HELP UNLEARN V for more information.
Syntax •
Run QuicSet®: QUIC[SET] Y
Rev 2.4.1, Nov 2008
HawkEye 1500 Reference & Programmers Manual
1-139
1 Remote Commands Reference
QUICSET
Page 154
Chapter
1
Remote Commands Reference
•
Cancel QuicSet®: QUIC[SET] N
•
Display the current setting for QuicSet®: QUIC[SET] ?
1-140
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov
Page 155
QUICSETPLUS This command allows you to specify what functions QuicSet® can perform.
Syntax QUICSETPLUS {TrigPolDetect} {MatchStringDetect} {Allow Learn} {Allow Save} Where: TrigPolDetect, (Y | N) If Y, then the trigger polarity of the OPTO IN signal at the time of successful exit from QuicSet® is set automatically as the triggering “edge.” The default is N. MatchStringDetect, (Y | N) If Y, then the data encoded in the symbol used for QuicSet® alignment is set automatically as the “match string.” For more information about match string, type HELP MATCH. The default is N. Allow Learn, (Y | N) If Y, then allow Learn and Unlearn button presses while in QuicSet alignment. The default is Y. Allow Save, (Y | N) If Y, automatically save all data to Flash after Learn or Unlearn. Otherwise, just RAM will be updated. The default is Y.
Rev 2.4.1, Nov 2008
HawkEye 1500 Reference & Programmers Manual
1-141
1 Remote Commands Reference
QUICSETPLUS
Page 156
Chapter
1
Remote Commands Reference
RATIO This command sets the expected width to height ratio. In READ mode, when HEIGHT and WIDTH are set to AUTO, RATIO can set the expected ratio. If the ratio may change, use RATIO AUTO. For a square Data Matrix, the ratio is 1.0, which means you should use RATIO 10. Note: See also “HEIGHT” on page 1-70 and “WIDTH” on page 1-202.
Syntax RATIO {opt} Where: opt, Is either of the following:
1-142
– ratio, Range: 3 - 50 (3 = 0.3; 50 = 5.0)
–
AUTO, Autoselect (default)
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov
Page 157
READ_LICENSE
1
This command determines whether or not an Option’s license is installed. It also allows you to check the status of installed options.
Remote Commands Reference
READ_LICENSE
Syntax READ_LICENSE [VERIFICATION | ?] •
•
READ_LICENSE VERIFICATION returns: –
VERIFICATION ON (if enabled)
–
PARAMETER INVALID (if disabled or unavailable)
READ_LICENSE ? displays a list of enabled options. For example: READ_LICENSE UIDCK ON READ_LICENSE VERFICATION ON
Rev 2.4.1, Nov 2008
HawkEye 1500 Reference & Programmers Manual
1-143
Page 158
Chapter
1
Remote Commands Reference
RELEASE This command releases control of the camera, allowing other users access to it.
Syntax RELEASE
1-144
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov
Page 159
REMOVE This command removes the assigned PID from the indicated trigger. When the specified trigger occurs, (to indicate the read and decode of an image), the default current PID parameters will be used by the decoder.
Syntax REMOVE {trig} Where: trig, Is the trigger number: Range: 0 - 27
Rev 2.4.1, Nov 2008
HawkEye 1500 Reference & Programmers Manual
1-145
1 Remote Commands Reference
REMOVE
Page 160
Chapter
1
Remote Commands Reference
REPORTCANCEL This command cancels a pending REPORTREQ command. This command is only used by ReadRunner.
Syntax REPORTCANCEL
1-146
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov