Page 141
PARTQSUM This command displays a summary of the part queue.
Syntax PARTQSUM {opt1} Where: opt1, Is the kind of summary to display:
Rev 2.4.1, Nov 2008
–
All, Display a complete summary. This is the default.
–
#, Display a summary of the # record. This is a zero-based index.
HawkEye 1500 Reference & Programmers Manual
1 Remote Commands Reference
PARTQSUM
1-127
Page 142
Chapter
1
Remote Commands Reference
PHOTOEX This command sets both Auto and Manual settings in one command.
Syntax PHOTOEX {opt1} {opt2} {opt3} {opt4} {opt5} {opt6} {opt7} Where: opt1, Sets the Photometry control: –
AUTO
–
MANUAL, Sets the operating Gain and Exposure opt2, The desired exposure if Manual control is selected opt3, The desired gain if Manual control is selected. Sets up the range for the auto photometry algorithm if Auto control. opt4, Min exposure, The minimum shutter/exposure duration value used for Auto control. (30 - 100,000 usec) opt5, Max exposure, The maximum shutter/exposure duration value used for Auto control. (Min exp - 100,000 usec) opt6, Min gain, The minimum gain value used for Auto control. (0 - 1023) opt7, Max gain, The maximum gain value used for Auto control. (Min Gain - 1023)
1-128
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov
Page 143
PHOTOMETRY This command selects Photometry settings and controls. An application can use user selected gain and exposure or it can use the auto-photometry algorithm to determine the correct settings at each trigger.
Syntax •
Define automatic photometry control. Perform photometry control at each trigger and prior to each image scan: PHOTO[METRY] AUTOMATIC [opt2] [opt3] [opt4] [opt5] Where: opt2, Min exposure, The minimum shutter/exposure duration value used for Auto control. (30 - 100,000 usec) opt3, Max exposure, The maximum shutter/exposure duration value used for Auto control. (Min exp - 100,000 usec) opt4, Min Gain, The minimum gain value used for Auto control. (0 - 1023) opt5, Max Gain, The maximum gain value used for Auto control. (Min Gain - 1023)
•
Define manual photometry control. Do not perform automatic photometry at each trigger. If opt2 and opt3 are supplied, use these values at each scan. Each PID can have its own gain and exposure settings: PHOTO[METRY] MANUAL [opt2] [opt3] Where: opt2, Exposure range (30 - 100,000 usec) opt3, Gain (0 - 1023)
Rev 2.4.1, Nov 2008
HawkEye 1500 Reference & Programmers Manual
1-129
1 Remote Commands Reference
PHOTOMETRY
Page 144
Chapter
1
Remote Commands Reference
PID This command allows you to train the decoder to rapidly and accurately decode the symbol in the current field of view. After the parameters are established, you can save the predictable parameters with the STORE command. The camera can store up to 15 predictable parameter sets, which are identified by ID 1 - 15 (PIDs). Each PID contains the following information: TABLE 1–13. Parameters Stored in Each PID
Parameter
Notes
Photometry
Gain & Exposure only. NOTE: If Autophotometry is ON (System parameters), then these PID settings are NOT used.
PreProcessing
Morphology operator and iterations
Decoder
All decoder parameters.
By default, Microscan supplies factory default PID99, which is programmed to read most codes with the HawkEye™ 1500. The default parameters are loaded into the current working area at boot time. After you start changing parameters from the ones in the current working area, the PID number changes to PID0, indicating that it has no home. You should store the info to a PID so that when you issue a SAVE command, your data is available. By default, if you issue the SAVE command without storing PID0, the data is stored to PID1. Depending on which PID is in the working area when you issue the SAVE command, the PID will be loaded the next time you boot the camera. PID 0 is the current PID info being used. PID 99 is the default PID information used to start from factory defaults. There are options and configurations available to advanced users. ASSIGN {pid#} {trigger#} You can ASSIGN {pid#} to {trigger#}. Because there are 28 real/virtual triggers, you can program the camera to “trigger” and indicate that a specific symbol is in the field of view and ready to be decoded. The camera pre-loads the decoder with the specific parameters for that product as the image is being lifted. When the image is in RAM, the “learned” parameters are used to rapidly and accurately
1-130
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov
Page 145
decode the image. Thus, several “learned” products can be used on the same line without stopping and re-programming the camera. VIEW PID {pid#} You can VIEW PID {pid#} to validate what you have stored. LOAD PID {pid#} If you do not want to use multiple PIDs, you can LOAD PID {pid#} into the current parameters and any trigger will use those parameters.
Rev 2.4.1, Nov 2008
HawkEye 1500 Reference & Programmers Manual
1-131
1 Remote Commands Reference
PID
Page 146
Chapter
1
Remote Commands Reference
POLARITY This command sets expected polarity of the Data Matrix.
Syntax POL[ARITY] {opt} Where: opt, Is one of the following:
1-132
–
AUTO (default)
–
DL, Dark on light
–
LD, Light on dark
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov
Page 147
POSITION_ENHANCE_ENABLED See “FINETUNE” on page 1-66.
Rev 2.4.1, Nov 2008
HawkEye 1500 Reference & Programmers Manual
1 Remote Commands Reference
POSITION_ENHANCE_ENABLED
1-133
Page 148
Chapter
1
Remote Commands Reference
PROBE DIRECTION This command sets the Probe direction.
Syntax PROBE DIRECTION {opt} Where: opt, Is one of the following:
1-134
–
HORI(zontal)
–
HORI_VERT (default)
–
VERT(ical)
–
VERT_HORI
–
CRISS_CROSS
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov
Page 149
PROBE SPEED This command sets the Probe speed. Caution: Increasing the probe speed may adversely affect the robustness of the reading.
Syntax PROBE SPEED {opt} Where: opt, Is one of the following:
Rev 2.4.1, Nov 2008
–
NORMAL (default)
–
OVERDRIVE
–
TURBO
HawkEye 1500 Reference & Programmers Manual
1-135
1 Remote Commands Reference
PROBE SPEED
Page 150
Chapter
1
Remote Commands Reference
PROBE THRESHOLD This command sets the Probe threshold level that the edge should exceed.
Syntax PROBE THRESHOLD {opt} Where: opt, Is the probe threshold level: Range: 5 - 100 Default: 18
1-136
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov