The text of a manual · part 33 of 37
Quadrus EZ Reader User's Manual, pages 321 to 330
Pages 321 to 330 of 366
The original document is the PDF (2.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Microscan EZ 6700 EX
Page 321
Appendices Image Processing Timeout <K245,image processing timeout> Hollow Mode <K517,hollow status> Output Format Format Extract <K740,output index,start location,length> Format Insert <K741,output index,length,hex string> Format Assign <K742,symbol number,status> Format Status <K743,output format status> <K744,filter number,symbology type,length,wildcard, placeholder, Output Filter Configuration data,unused,database index> Ordered Output Filter <K745,number of filters> Format Extract <K740,output index,start location,length>
Quadrus EZ Reader User’s Manual
A-17
Page 322
Serial Configuration Commands
Serial Command Format Serial commands are of two types: utility and configuration.
Rules that apply to both utility and configuration commands • A less than < and greater than > characters enclose the commands. • Commands and data are “case sensitive.” That is, characters must be entered as upper or lower case, as specified.
Serial Utility Commands These are sent during operations and are not followed by a <A> or <Z>.
Serial Configuration “K” Commands These begin with a single K character followed by a 3-digit numeric character, data fields, and an initializing command, as follows: <Knumeric parameter,data,data,...etc.><initializing command> An initializing command <A> or <Z> may follow the command. A <Z> initializes the reader’s memory and saves for power-on; an <A> initializes the reader’s memory but does not save for power-on. For example, to enable UPC and save the change for power-on, send <K473,1><Z>. To change Baud Rate and reset without saving changes for power-on, send <K100,3><A>.
Serial Configuration Command Conventions • All data fields (except the last) must be followed by a comma (without a space). • The following characters cannot be used: , < > NULL. • All fields preceding a modified field must be included. • If there is no change in preceding fields, then commas alone can be entered in these fields. For example, if only the last field in the following command is changing, <K100,4,1,0,0> can be entered as <K100,,,,0>. • All fields following a modified field can be omitted. For example, to change Baud Rate only, send <K100,3>.
Concatenating Configuration Commands Commands can be concatenated (added together) in a single string or data block. For example, <K145,1><K220,1><K450,1><A> enables LRC, sets End of Read Cycle mode to New Trigger, enables Narrow Margins, and resets the data buffers (without saving the changes for power-on).
A-18
Quadrus EZ Reader User’s Manual
Page 323
Appendices
Serial Command Status Request To ensure that any command was received and accepted, you can send the Show Reader Status command: <?>. The status of a specific serial command can be requested by entering the command followed by a question mark. For example, send <K142?> to request the status of Postamble.
Entering Special Characters in Serial Commands To enter control characters within a serial command, hold down the control key while typing the desired character. Example: To enter a carriage return and line feed (^M^J), enter <K141,1,CNTL-m CNTL-j>
Entering Special Characters in Embedded Menus Control Characters Control characters entered on the command line are displayed in the menu as mnemonic characters, such as: <CR><LF><NUL><NUL>. Press SP (the space bar) once, then enter the control character by holding down the control key and simultaneously pressing the desired character. For example to define a line feed, press SP, then Control and J simultaneously. It is displayed as ^J on the command line and as <LF> in the menu when the screen is refreshed.
To Define a Carriage Return as a Character Press SP, then CR. It is displayed as ^M on the command line and as <CR> in the menu when the screen is refreshed.
To Define a Space as a Character Press SP twice. It is displayed as a blank space in the menu when the screen is refreshed. While it appears that nothing has been assigned, the hex value 20 will be sent during data transmission.
To Select NUL as the Character Press SP, then a 0 (zero). It is displayed as <NUL> in the menu when the screen is refreshed.
Quadrus EZ Reader User’s Manual
A-19
Page 324
ASCII Table
Appendix G, ASCII Table ASCII Table with Control Characters Dec 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
A-20
Hex 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F
Mne NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US
Ctrl ^@ ^A ^B ^C ^D ^E ^F ^G ^H ^I ^J ^K ^L ^M ^N ^O ^P ^Q ^R ^S ^T ^U ^V ^W ^X ^Y ^Z ^[ ^\ ^] ^^ ^_
Dec 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63
Hex 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F
Ch SP ! “ # $ % & ' ( ) * + , . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ?
Dec 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95
Hex 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F
Ch @ A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ \ ] ^ _
Dec 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127
Hex 60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F
Ch ` a b c d e f g h i j k l m n o p q r s t u v w x y z { | } ~ D
Quadrus EZ Reader User’s Manual
Page 325
Appendices Communication Protocol Commands Protocol Command (Mnemonic displayed on Microscan menu)
Control Characters (Entered in menu or serial command)
Hex Code
Effect of Command
RES
^D
04
Reset
REQ
^E
05
Request
EOT
^D
04
Reset
STX
^B
02
Start of Text
ETX
^C
03
End of Text
ACK
^F
06
Acknowledge
NAK
^U
15
Negative Acknowledge
XON
^Q
11
Begin Transmission
XOFF
^S
13
Stop Transmission
Quadrus EZ Reader User’s Manual
A-21
Page 326
Data Matrix Symbology
Appendix H, Data Matrix Symbology Individual element (or module) A white corner on a white background symbol indicates an even number of elements per side, a black corner indicates an odd number. Even number of elements per side indicates an ECC 200; an odd number indicates 000 to 140 (in most cases) Alternating finder pattern on two sides used to define cell structure Solid finder pattern on two sides define physical size, orientation and symbol distortion
Data Matrix Symbol Comparisonl Symbol Features Number of rows and columns (including finder pattern) Element in upper right hand corner Error correction routine Symbol sizes (not including quiet zones) Append in structured format Subdivide code word stream into blocks for error detection Extended channel interpretation for other character sets Data encoded in:
A-22
ECC 000 - 140 Odd (except for some closed applications) Dark (for light background symbols) Convolution 17 to 21 sizes (squares only) No
ECC 200 Even
No
Light (for light background symbols) Reed-Solomon 24 squares 6 rectangular Yes, up to 16 symbols Yes, for symbols with more than 255 code words
No
Yes, optional
Base 11, 27, 41, 37, ASCII, 8-bit Byte
ASCII, C40, text, X12, EDIFACT, and Base 256
Quadrus EZ Reader User’s Manual
Page 327
Appendices
Appendix I, Determine Depth of Field If symbols appear in the FOV at a consistent distance in your application, you could simply set up for the recommended focal length and omit this test. However, if your symbols appear at varying focal lengths, we recommend that you perform the following test to determine the inner and outer read distances for your symbol type. 1. Position the symbol at the focal distance recommended on the back of your reader. 2. Position the symbol relative to the reader so that the distance to the reader can be shortened or extended. Ideally, you should have the symbol mobile and the reader mounted on a stand. 3. Move the symbol towards the reader and away from the reader until the decode rate and/or green LED light drops off in each direction as shown in the illustration on the right.
u
De p th of f ield
This will give you a sense of the depth of field (inner and outer ranges) for your symbol’s density and focal distance. Note: Depth of field will vary according to lens type. Typically, the narrow and medium lens type readers will have less depth of field than the wide and extra wide readers.
Quadrus EZ Reader User’s Manual
A-23
Page 328
Field of View and Lenses
Appendix J, Field of View and Lenses Representations of two lens type views are shown in the drawing below. Notice that while FOVs vary considerably by lens type and focal distance (the distance from the front of the reader - also called “object distance”), the image sensor sizes are fixed. This is the case with the both the CMOS and CCD which use the same sensor size for all lens types. Wide lens
FOV
Image sensor
Extra wide angle lens
Image sensor
FOV
Pixels and Resolution Wider lenses mean a wider Wide angle lens Extra-wide angle lens FOV, but lower resolutions. This is because the number of pixels on the image sensor, whether CCD or CMOS, is the same for all lens types. So if you increase the FOV - by going to a larger lens type or a longer focal distance - the resolution (the number of pixels available for a given area) diminishes. In the representations to the right, the extra-wide lens has the same number of pixels available as the wide angle at similar distances, but since the wide angle’s FOV is about half that of the extra-wide’s FOV, its resolution is therefore double. This can be stated in two rules: 1. At any given focal distance, the smaller the lens type, the higher the resolution. 2. For any given lens type, the shorter the focal distance, the higher the resolution.
A-24
Quadrus EZ Reader User’s Manual
Page 329
Appendices
Relative Sizes of FOVs by Lens Type at 4” Focal Distance Note: FOV representations are approximate and should not to be used for actual measurement.
.49” 12.4mm
.78” 19.8mm
Narrow
1.41” 35.8mm
.71” 18.0mm
.56” 14.2mm
.37” 9.40 mm
1.88” 47.8mm
.95” 24.1mm
Medium
Wide
Extra wide
Quadrus EZ Maximum 2D Symbol Sizes Maximum Element Sizes by Lens Type at 4” (101.6mm) Focal Distance Lens Type Field of View X-dimension
Narrow
Medium
Wide
Extra Wide
.49” (12.4mm)
.78” (19.8mm)
.95” (24.1mm)
1.88” (47.8mm)
.37” (9.40mm)
.56” (14.2mm)
.71” (18.0mm)
1.41” (35.8mm)
.355” (9.0mm) 64 x 64 48 x 48
.538” (13.7mm)
.68” (17.3mm)
1.35” (34.3mm)
64 x 64 48 x 48
88 x 88 64 x 64 64 x 64 48 x 48
Y-dimensiona
Symbol .005” (.127mm) .0075 (.191mm) .010 (.254mm) .015 (.381mm)
Adjusted Yb Aligned to FOV Rotatedc Aligned to FOV Rotated Aligned to FOV Rotated Aligned to FOV Rotated
88 x 88 64 x 64 a. The Y-dimension = X-dimension x 75%. b. A 20 pixel combined top and bottom buffer (96%) around the symbol is the adjusted Y-dimension. c. When 2D symbols are rotated 45°, their maximum Y-dimension is divided by 1.41 to assure readability.
Notes: • Dynamic symbols that are close in size to the maximum field of view limitations may prove difficult to read unless their vertical placements are precisely controlled. • Good read opportunities are enhanced in Rapid Capture mode by ensuring the maximum number of Rapid Captures occur while the symbol is in the field of view.
Quadrus EZ Reader User’s Manual
A-25
Page 330
Field of View and Lenses CCD Focal Distance, FOV, DOF and Symbol Size by Lens Type Focal Distance Inches mm 3.50 3.75 4.00 4.25 4.50 4.75 5.00
88.9 95.3 101.6 108.0 114.3 120.7 127.0
2.25 3.00 3.50 4.00 5.00 6.00 7.00 8.00 9.00 10.00
57.2 76.2 88.9 101.6 127.0 152.4 177.8 203.2 228.6 254.0
2.00 3.00 4.00 5.00 6.00 7.00 8.00 9.00 10.00
50.8 76.2 101.6 127.0 152.4 177.8 203.2 228.6 254.0
2.50 3.00 4.00 5.00 6.00 7.00 8.00 9.00 10.00
63.5 76.2 101.6 127.0 152.4 177.8 203.2 228.6 254.0
2.50 3.00 4.00 5.00 6.00 7.00 8.00 9.00 10.00
63.5 76.2 101.6 127.0 152.4 177.8 203.2 228.6 254.0
A-26
Field of View Depth of Field Inches mm Inches mm Narrow Lens 0.33 8.4 0.20 5.1 0.39 9.9 0.20 5.1 0.44 11.2 0.20 5.1 0.49 12.4 0.20 5.1 0.55 14.0 0.20 5.1 0.59 15.0 0.40 10.2 0.65 16.5 0.40 10.2 Medium Lens 0.44 11.2 0.10 2.5 0.59 15.0 0.50 12.7 0.68 17.3 0.50 12.7 0.77 19.6 0.50 12.7 0.94 23.9 1.00 25.4 1.12 28.4 1.00 25.4 1.30 33.0 2.20 55.9 1.49 37.8 2.50 63.5 1.63 41.4 2.60 66.0 1.78 45.2 4.20 106.7 Wide Lens 0.49 12.4 0.10 2.5 0.72 18.3 0.50 12.7 0.93 23.6 1.00 25.4 1.13 28.7 2.00 50.8 1.35 34.3 2.20 55.9 1.56 39.6 2.80 71.1 1.76 44.7 4.20 106.7 1.96 49.8 4.20 106.7 2.17 55.1 4.80 121.9 Extra Wide Lens (for 2D symbols) 1.26 32.0 1.00 25.4 1.45 36.8 1.00 25.4 1.84 46.7 1.00 25.4 2.22 56.4 2.00 50.8 2.58 65.5 3.60 91.4 2.94 74.7 4.20 106.7 3.33 84.6 4.20 106.7 3.70 94.0 5.80 147.3 4.18 106.2 6.00 152.4 Extra Wide Linear Lens (for linear symbols) 1.26 32.0 0.60 15.2 1.45 36.8 1.10 27.9 1.84 46.7 1.40 35.6 2.20 55.9 2.80 71.1 2.60 66.0 3.00 76.2 2.96 75.2 3.80 96.5 3.33 84.6 3.80 96.5 3.73 94.7 5.00 127.0 4.14 105.2 6.80 172.7
Symbol Element Size Inches mm 0.0050 0.0050 0.0050 0.0050 0.0050 0.0075 0.0075
0.127 0.127 0.127 0.127 0.127 0.191 0.191
0.0050 0.0075 0.0075 0.0075 0.0100 0.0100 0.0150 0.0150 0.0150 0.0200
0.127 0.191 0.191 0.191 0.254 0.254 0.381 0.381 0.381 0.508
0.0050 0.0075 0.0100 0.0150 0.0150 0.0150 0.0200 0.0200 0.0200
0.127 0.191 0.254 0.381 0.381 0.381 0.508 0.508 0.508
0.0150 0.0150 0.0150 0.0200 0.0300 0.0300 0.0300 0.0400 0.0400
0.381 0.381 0.381 0.508 0.762 0.762 0.762 0.1016 0.1016
0.0075 0.0100 0.0100 0.0150 0.0150 0.0200 0.0200 0.0200 0.0300
0.191 0.254 0.254 0.381 0.381 0.508 0.508 0.508 0.762
Quadrus EZ Reader User’s Manual