The text of a manual · part 32 of 37
Quadrus EZ Reader User's Manual, pages 311 to 320
Pages 311 to 320 of 366
The original document is the PDF (2.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Microscan EZ 6700 EX
Page 311
Appendices
Optoisolator Inputs All discrete inputs can be fully isolated pulses as PNP or NPN circuits. Inputs include trigger, new master, and input 1. Generic Waveform Characteristics Minimum
Input (+) I load
Maximum
VIN-HIGH/IINHIGH
4.5V/4mA
28V/33mA
VIN-LOW/IIN-LOW
0 V/0mA
2 V/2mA
Pulse Widthmin
48 µS
Input (–)
Input Examples Fully Optoisolated PNP Source +V
Isolated Scanner V CC
NPN Source
Isolated Scanner V CC
+V Input (+)
Signal Input (+)
Input (–)
Input (–)
Signal
Not Optoisolated PNP Source
Non-isolated Scanner V CC
Power (+) Input (+)
+V
V CC Signal
NPN Source
Non-isolated Scanner Power (+)
+V
Input (+) Input (–)
Input (–)
Power ground
Quadrus EZ Reader User’s Manual
Power ground
Signal
A-7
Page 312
Quadrus EZ DPM
Appendix C, Quadrus EZ DPM The Quadrus EZ is now available in an option specifically for direct part mark applications. The Quadrus EZ DPM Imager (FIS-6700-04XXG-XXXX) is optimized to read low-contrast direct part marks on challenging surfaces such as metal, plastic, rubber, and glass. The even illumination provided by the light diffuser and unique LED array minimizes specular reflection and improves symbol readability. Contact your distributor or refer to Microscan’s Product Pricing Catalog for detailed information about focal distance options and Quadrus EZ DPM accessories. Input/Output ports (back) EZ Button for out-of-the-box testing and configuration
Illumination diffuser
Standard illumination often creates specular reflection on parts with highly reflective or irregular surfaces. This can negatively impact direct part mark readability. The Quadrus EZ DPM Imager reduces specular reflection by diffusing LED illumination.
Standard
Diffused
Recommended Applications • Automotive assembly and power train • Aerospace assembly • Electronics manufacturing • Medical device manufacturing Important: The Quadrus EZ DPM Imager retains all other standard Quadrus EZ functionality. A-8
Quadrus EZ Reader User’s Manual
Page 313
Appendices
Appendix D, Quadrus EZ FLEX The Quadrus EZ FLEX (FIS-6700-2001G) retains the firmware functionality of the standard Quadrus EZ, and adds the flexibility of a manual focus C-Mount lens and external LED illumination. Contact your distributor or refer to Microscan’s Product Pricing Catalog for detailed information about focal distance options and Quadrus EZ FLEX accessories. Ethernet and Video I/O ports (back) EZ Button for out-of-the-box testing and configuration
Optional C-Mount lens
Components for a Complete Solution
General Purpose Lens/Illumination 98-000100-02
Complete Solution
Micro-Density Lens/Illumination 98-000100-01
Complete Solution
Camera FIS-6700-2001G
Recommended Applications • Factory automation • Parts traceability • Work-in-progress
Quadrus EZ Reader User’s Manual
A-9
Page 314
Connectivity Accessories
Appendix E, Connectivity Accessories Three interface options are available for Quadrus EZ connectivity.
IB-150 Kit The IB-150 interface links the Quadrus EZ to the host, power supply, trigger, and aux port connections. In addition to multidrop and daisy chain hookups, the aux port can plug into the IB-152 interface for terminal strip wiring. Quadrus EZ
Quadrus EZ Cable T RIGGER POWER
HOST
IB-150 Interface
READER
QUAD RUS EZ ™
AUX PORT
IB-150
IB-150 Port Connectors
Trigger 4-pin Connector
Pin
Reader
Host
Aux Port
Pin
Function
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Chassis ground TxD RxD RTS/Aux TxD CTS/Aux RxD Output 1 (+) Signal GND Output 2 (+) Trigger (–) Trigger (+) Default Input 1 (+) RxD (+) TxD (–) Output 3 (+) RxD (–) Power ground +10 to 28 VDC TxD (+) Output 1 (–) Output 2 (–) Output 3 (–) Input 1 (–) New master (–) New master (+)
Chassis ground TxD RxD RTS/Aux TxD CTS/Aux RxD Output 1 (+) Signal GND Output 2 (+) Trigger (–) Trigger (+) Default Input 1 (+) RxD (+) TxD (–) Output 3 (+) RxD (–) NC NC TxD (+) Output 1 (–) Output 2 (–) Output 3 (–) Input 1 (–) New master (–) New master (+)
Chassis ground RxD TxD NC NC Output 1 (+) Signal GND Output 2 (+) Trigger (–) Trigger (+) Default Input 1 (+) RxD (+) TxD (–) Output 3 (+) RxD (–) Power ground +10 to 28VDC TxD (+) Output 1 (–) Output 2 (–) Output 3 (–) Input 1 (–) New master (–) New master (+)
1 2 3 4
Power + 10 to 28VDC (out)a Trigger (–) (in)b Power Ground Trigger (+) (in)a
A-10 a. For NPN type, connect pins 1 and 4. b. For PNP type, connect pins 2 and 3.
Power 3-pin Connector Pin
Function
1 2 3
Power Ground Chassis Ground Power + 10 to 28VDC (in)
Note: The IB-151 should be used whe establishing an Ethernet connection.
Quadrus EZ Reader User’s Manual
Page 315
Appendices
IB-151 Ethernet/USB Interface USB (USB-B) and standard Ethernet (RJ-45) connections can be made through the IB-151 interface which plugs directly into the host port of the Quadrus EZ. The IB-151 has an second 25-pin port to pass through all but the RS-422/485 connections. Ethernet (socket)
USB Connector (socket) Quadrus EZ
3 2
1
4
QU ADRU S E Z ™
IB-151 8
1
Category 5 cabling less than 50 m in length is recommended
1
25
Host Connector (plug)
IB-151 Ethernet Pin 1 2 3 4 5 6 7 8
Ethernet Port Ethernet TX (+) Ethernet TX (–) Ethernet RX (+) NC NC Ethernet RX (–) NC NC
IB-151 USB Pin 1 2 3 4
USB Port +5VDC Data (–) Data (+) GND
IB-151 Host Pin 13 14 16 19
Host Porta NC NC NC NC a. All other pins are as shown on the reader port of the IB-150.
Important Notes For ethernet connection, the IB-151 is recommended for the following reasons: • Protection components are installed within the IB-151 to address ethernet susceptibility to line transients and electrostatic discharge (ESD) that can cause communication dropouts and connection termination. • The IB-150’s matching cable does not provide the proper matched impedance that the standard CAT 5 cable provides, thus allowing higher emission levels which exceed Class A CE limits and possible further signal degradation.
Quadrus EZ Reader User’s Manual
A-11
Page 316
Connectivity Accessories
IB-152 Terminal Strip Interface Kit Custom terminal strip wiring can be done through the IB-152 interface, which can either connect directly to the Quadrus EZ or indirectly by way of the aux port of the IB-150. Note: The IB-152 kit includes a gender changer. The gender changer is only used for direct connection between the IB-152 and the Quadrus EZ.
IB-150 QUAD RUS E Z ™
TRIGGER POWER
HOST
IB-150 Interface
READER
AUX PORT
Quadrus EZ Gender Changer
IB-152
Note: Inside terminal assembly can be flipped over as required by application.
Steps for wiring the IB-152 Interface:
25
1. Remove two screws from top case at these locations.
(plug)
1 2. Pry at this point to separate cases 3. Connect external wires to terminal connections as marked. (See host or aux port pinouts on IB-150.)
12 11 10 9
8
7
6
5
4
25
22
A-12
2
1
13
24 23
3
14 21 20 19 18 17
15 16
Quadrus EZ Reader User’s Manual
Page 317
Appendices
Appendix F, Serial Configuration Commands The following table is a summary of all the available serial configuration commands, presented in the order found in the chapters. Serial Configuration Commands Communications Host Port Connections Host Port Protocol Host 232/422 Status
<K100,baud rate,parity,stop bits,data bits> <K140,protocol> <K102,host 422> <K101,aux port mode,baud rate,parity,stop bits,data Auxiliary Port bits,daisy chain ID status,daisy chain ID> Daisy Chain Autoconfigure <K150DAISY> Daisy Chain ID <K151,daisy chain reader #,daisy chain reader ID> <K125,IP address,subnet address,gatewayaddress,IP Ethernet Configuration address mode,primary TCP port,video TCP port> Preamble <K141,status,preamble characters> Postamble <K142,status,postamble characters> Response Timeout <K143,response timeout> LRC <K145,status> Aux Port System Data Status <K146,aux port system data> Read Cycle Multisymbol <K222,number of symbols,multisymbol separator> Trigger Mode/Duration <K200,trigger mode,trigger filter duration> External Trigger State <K202,extermal trigger state> Serial Trigger Character <K201,serial trigger character> Start Trigger Character <K229,start character> Stop Trigger Character <K230,stop character> End of Read Cycle <K220,end of read cycle,read cycle timeout> Active Camera <K240,active camera> <K241,capture mode,number of captures,rapid capture Captures mode> <K242,time before 1st capture,time between capture 1 and Capture Timing 2,,,,,,,,time between capture 7 and 8> <K243,switching mode,number of internal camera captures, Dual Camera Operations number of external camera captures,internal camera timeout, external camera timeout> Store Noread Image <K244,image storage type,image storage mode>
Quadrus EZ Reader User’s Manual
A-13
Page 318
Serial Configuration Commands
Symbologies Data Matrix QR Code Code 39 Code 128 BC412 Interleaved 2 of 5 UPC/EAN Pharmacode DataBar Expanded DataBar Limited DataBar-14 PDF417 Micro PDF417 Composite Narrow Margins/ Symbology ID Background Color Unique Item Identifiers (UII) I/O Parameters Symbol Data Output Noread Message Bad Symbol Message No Symbol Message 1D/Stacked Symbology Qualification
A-14
<K479,ECC 200 status,ECC 000 status,ECC 050 status,ECC 080 status,ECC100 status,ECC140 status,ECC 120 status,ECC 130 status> <K480,status> <K470, status,check digit status,check digit output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> <K474,status,fixed symbol length status,fixed symbol length> <K481, status,check digit output,fixed symbol length status,fixed symbol length> <K472,status,check digit status,check digit output,symbol length #1,symbol length #2,guard bar> <K473,UPC status,EAN status,supplementals status,separator status,separator character,supplemental type> <K477,status,fixed symbol length status,fixed symbol length,min. no. of bars,bar width status,direction,fixed threshold value> <K484,status,fixed symbol length status,fixed symbol length> <K483,status> <K482,status> <K476,status,[unused],fixed symbol length status,fixed symbol length,[unused],codeword collection> <K485,status,[usused],fixed symbol length status,fixed symbol length> <K453,mode,separator status,separator> <K450,narrow margins,symbology identifier status> <K451, background color> <K455,status,errstatus>
<K705,symbol data output status,when to output> <K714,noread message status,noread message> <K715,[unused],message> <K716,[unused],message> <K717,minimum number of bars,minimum number of qualified scans,start/stop status>
Quadrus EZ Reader User’s Manual
Page 319
Appendices <K718,finder pattern status,symbol size mode,symbol size 1,symbol size 2,symbol size tolerance,dimension mode,dimension 1,dimension 2,dimension tolerance,orientation mode,orientation value> Read Duration Output <K706,status,separator> LED Indicators <K750,green flash mode,x-pattern status,green flash duration> Beeper <K702,beeper status> LED Configuration <K737,LED mode,ISO/IEC 15415 grade,DPM grade> <K701,serial command echo status,serial command beep staSerial Verification tus,control/hex output> Video Output <K760,video output mode,trigger image mode,image frame> Image Output <K739,image output mode,comm port,file format,JPEQ quality> Image Captioning <K762,mode> Synchronous Trigger <K761,synchronous trigger mode> <K770,global status,default on power-on,load IP database,save EZ Button for power-on> <K771,position 1 mode,position 2 mode,position 3 mode,posiEZ Button Modes tion 4 mode> Input 1 <K730,input mode,active state> Output 1 Parameters <K810,output on,active state,pulse width,output mode> <K780,trend analysis mode,number of triggers,number to outTrend Analysis Output 1 put on> <K800,output on symbol contrast,symbol contrast threshSymbol Quality (ISO/IEC old,output on print growth,print growth threshold,output on axial non-uniformity,axial non-uniformity threshold,output on unused 15415) to Output 1 ecc,unused ecc threshold> <K820,output on dot center offset,dot center offset,output on Symbol Quality (Inkjet/ cell fill,cell fill,output on dot ovality,dot ovality threshold,output Direct) on angle of distortion,angle of distortion threshold> to Output 1 Diagnostic Warnings <K790,over temp,service unit,external camera disconnect> to Output 1 Output 2 <K811,output on,active state,pulse width,output mode> <K781,trend analysis mode,trigger evaluation period,number to Trend Analysis Output 2 output on> <K801,output on symbol contrast,symbol contrast threshSymbol Quality (ISO/IEC old,output on print growth,print growth threshold,output on axial non-uniformity,axial non-uniformity threshold,output on unused 15415) to Output 2 ecc,unused ecc threshold> <K821,output on dot center offset,dot center offset,output on Symbol Quality (Inkjet/ cell fill,cell fill,output on dot ovality,dot ovality threshold,output Direct) on angle of distortion,angle of distortion threshold> to Output 2 Diagnostic Warnings <K791,over temp,service unit,external camera disconnect> to Output 2 2D Symbology Qualification
Quadrus EZ Reader User’s Manual
A-15
Page 320
Serial Configuration Commands Symbol Quality Total Read Time (global) <K710,[not changed in this context],total read time> Symbol Quality Separator/ <K708,symbol quality separator,data matrix output mode> Data Matrix Output Mode ISO/IEC 15415 Symbol <K709,symbol contrast,print growth,axial nonuniformity, unused Quality ecc> <K710,percent cell damage,[see Total Read Time above],capture Grading Symbol Quality time,locate time,decode time,pixels per element,ecc level,matrix size,quiet zone> Matchcode <K223,type,sequential matching,match start position,match Matchcode Type length,wild card character,sequence on noread,sequence on mismatch> Sequence Step <K228,sequence step> New Master Pin <K225,status> Number of Master Sym<K224,number of master symbols> bols Enter Master Symbol <K231,master symbol number,data> Data Read Next Symbol as <G master symbol number> Master Symbol Request Master Symbol <K231?,>[for all] or <K231?,master symbol number> Data Delete Master Symbol <K231, master symbol number,> Data Diagnostics Power-on/Reset Counts External Camera Message Over Temperature Message Service Message Camera Region of Interest CCD Image Sensor CMOS Image Sensor Illumination Source Thresholding Image Processing Mode Multiple Symbols in Fast Linear Mode A-16
<K406,power-on,resets,power-on saves,customer default saves> <K410,disconnect msg status,disconnect message,connect msg status,control message> <K402,over temperature status,warning message> <K409,status,service message,threshold,resolution> <K516,top,left,height,width> <K540,shutter speed,gain> <K541,shutter speed,gain,contrast,offset> <K535,illumination source> <K512,threshold mode,threshold value> <K513,processing mode> <K518,number of symbols> Quadrus EZ Reader User’s Manual