The text of a manual · part 31 of 37
Quadrus EZ Reader User's Manual, pages 301 to 310
Pages 301 to 310 of 366
The original document is the PDF (2.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Microscan EZ 6700 EX
Page 301
Ethernet
Step 3, Communicating in Ethernet By now either the reader should be configured with an IP address or the host computer is configured to use the reader's default IP address. Now ESP needs configuration: 1. In ESP under the Connect pull down menu, select Settings… 2. Click the TCP/IP tab. 3. Type in the reader's IP address (as shown on the ESP Communications menu). 4. Click Connect. 5. After a few seconds, ESP should display “CONNECTED” at the bottom of the window.
Quadrus EZ Reader User’s Manual
15-7
Page 302
Step 4, Ethernet Application The Quadrus EZ supports the Microscan communication protocol for readers over two TCP/IP ports. This is the same “protocol” that is supported through the reader's RS-232 Host serial port. Note that on Ethernet, the Quadrus EZ is a server device, which requires the Host to establish the connection. Once the connection is established, however, the reader will send bar code and diagnostic message data whenever it is generated.
Network Protocols Supported The Quadrus EZ supports the following RFC-compliant protocols: IP RFC0791, RFC950 ICMP, PING RFC0792 TCP RFC0793 Sockets BSD v4.3 ARP RFC0826 DHCP client RFC0951, RFC1541, RFC2131, RFC2563 partial support TFTP server Revision 2, RFC1350 Communication with the Quadrus EZ can be established via a Telnet client (raw data only, no IAC command processing), or through a custom “sockets” application. The Quadrus EZ becomes a “server” device. It listens for connect requests from the Host before communication can begin. All Quadrus EZ readers have a unique 48-bit hardware (MACID) address. This address is printed on the reader's product label.
Microscan Protocol/Host RS-232 Supported • Configuration Commands (“K Commands”) • ESP interface commands (“<op>” commands) • Utility commands <A> - <Z> • Host preamble <K141> and postamble <K142> strings are added to command responses and bar code data. • All bar code data formatting is supported (<K740>, <K741>).
Differences from Other Protocols • Y Modem is not supported. This includes Firmware Download command <dy> and Image Send command <uy>. • Reader does not send an immediate response to the reader’s Status command <?>. The response is queued for output between read cycles. Also, the response is formatted with host-port preamble and postamble characters. • Aux port (RS-232) interaction is not supported for transferring data between Ethernet and the aux port (Transparent, Half-, Full- Duplex). These modes only function with the Host RS-232 port, and are not affected by Ethernet. • Reader sends responses to “binary frame” commands out the Video TCP port when connected. If not connected, the response will be sent to the Primary TCP port. 15-8
Quadrus EZ Reader User’s Manual
Page 303
Ethernet
Primary (Command) TCP Port This port is used for all command processing and data outputs (except “binary frame” command responses). The application protocol used is the same as the Host RS-232 port.
Video TCP Port The Video TCP port is transmit-only (output from the reader, read-only by the Host), and is used for “binary frame” data outputs as follows: 1. Response to Image Send command <op,4> 2. Response to Capture and Decode and Save command <op,5> 3. Response to Symbol Information command <op,8> 4. Response to Histogram command <op,14> The primary purpose of this port is for access to a dedicated video stream for Easy Setup Mode functions in Windows-based ESP configuration and evaluation program, in particular. Because the format of the “binary frame” data is quite different from the reader's other command responses and outputs, sending this data on a dedicated, independent TCP port facilitates easier ESP implementation. Also, end users who wish to implement their own applications may find this useful since it has a consistent data type and provides access to a port whose only traffic is that which the host application has initiated. The Video TCP port is read-only from the host's perspective. The reader does not receive any data or commands on this port. The reader only processes commands from the primary (Command) TCP port. Also, the reader only responds to the video port if the video port has a connection to the host and a command is received that requires a “binary frame” response. If the video port is unconnected, the reader will respond to the primary port. This allows hosts the option to operate over a single port.
Quadrus EZ Reader User’s Manual
15-9
Page 304
Image File Transfers The reader's image files can be accessed with either “binary frame” commands <op,4> and <op,5>, or TFTP.
Binary Frames These are primarily intended for ESP's “near-real-time video” purposes. Although it is possible to get a full-size image from the reader using an <op,4> or <op,5> command, for quicker response, it is recommended that TFTP be used.
TFTP Server A TFTP (Trivial File Transfer Protocol) client can access the reader's image files (the reader is a TFTP server). Since TFTP does not support any sort of directory structure, the host application must know the reader's file naming convention, or request an image list from the reader through the primary TCPIP port (or RS-232 port) with the <op,9> command.
Limitations The largest data size per packet (TCP MSS/MTU) the reader can receive and transmit is approximately 550 bytes. Since TCP/IP is used, this will not prevent larger data transmissions, but it will limit throughput. Some host network systems may find an MTU of 550 somewhat limiting, but this should not prevent operation with any network.
15-10
Quadrus EZ Reader User’s Manual
Page 305
Appendices Appendix A General Specifications...............................................................................................A-2 Appendix B Electrical Specifications.............................................................................................A-4 Appendix C Quadrus EZ DPM .....................................................................................................A-8 Appendix D Quadrus EZ FLEX .....................................................................................................A-9 Appendix E Connectivity Accessories.........................................................................................A-10 Appendix F Serial Configuration Commands..............................................................................A-13 Appendix G ASCII Table.............................................................................................................A-20 Appendix H Data Matrix Symbology ...........................................................................................A-22 Appendix I Determine Depth of Field ..........................................................................................A-23 Appendix J Field of View and Lenses .........................................................................................A-24 Appendix K Rapid Capture Mode ...............................................................................................A-28 Appendix L Object Detector ........................................................................................................A-30 Appendix M Operational Tips......................................................................................................A-31 Appendix N Embedded Menus ...................................................................................................A-32 Appendix O Interface Standards.................................................................................................A-33 Appendix P Multidrop Communications ......................................................................................A-34 Appendix Q Glossary of Terms...................................................................................................A-37
Quadrus EZ Reader User’s Manual
A-1
Page 306
General Specifications
Appendix A, General Specifications Mechanical Height: 2.25” (57 mm) Width: 2.5” (64 mm) Depth: 4.2” (107 mm) Weight: 12 oz. (340g)
Environmental Enclosure Rating: IP65 (standard unit) With video I/O option: IP54 Operating Temperature: 0° to 43°C (32° to 109°F) if mounted on a Microscan stand. If mounted on a non-metal surface, maximum operating temperature is 40°C (109°F) Storage Temperature: -50 to 75°C (-58 to 167°C) Humidity: up to 90% (non-condensing)
Emissions/Immunity ITE Disturbances: IEC 55022:1998 (radiated and conducted). Class A General Immunity: IEC 55024:1998 (residential) Heavy Industrial Immunity: IEC 61000-6-2:1999
Light Source Type: High output LEDs
Light Collection Progressive scan, square pixels. Software-adjustable shutter speed, electronic mechanism. CCD array: 659 x 494 pixels CMOS array: 640 by 480 pixels
Symbology Types 2D: Data Matrix (ECC 0-200), QR Code Stacked symbologies: PDF417, MicroPDF417, GS1 DataBar (Composite and Stacked) Linear: Code 39, Code 128, I 2/5, UPC/EAN, Pharmacode, BC412
Video Input (Option)
Quadrus EZ Reader Dimensions
Signal System: EIA (RS-170) Number of Scanning Lines: 525 lines, 30 fps, non-interlaced Input: Analog 1 Vp-p
Video Output (Option) Signal System: EIA Number of Scanning Lines: 525 lines, 2:1 interlaced Input: Analog 1 Vp-p/75 ohm
A-2
Quadrus EZ Reader User’s Manual
Page 307
Appendices
Read Parameters Pitch: ±30° Skew: ±30° Tilt: 360° Decode Rate: Up to 60 decodes per second Focal Range: 2 to 10 inches (factory-adjustable)
Indicators Beeper: Good Read, Match/Mismatch, No Read, serial command confirmation, On/Off LEDs: Read performance, Power, Read Status, Network Status
Communication Protocols Standard Interface: RS-232/422/485 Optional Interface: Ethernet
Electrical Power Requirements: Input, 10 to 28VDC, 200 mV p-p max. ripple, 270 mA at 24VDC (typ. CMOS), 333mA at 24VDC (typ. CCD) Trigger, New Master, Input 1: (Optoisolated) 5 to 28VDC rated (12mA at 24VDC) Outputs 1, 2, 3: (Optoisolated) 1 to 28VDC rated (ICE < 100mA at 24VDC, current limited by user)
Safety Certifications FCC, CE, UL/cUL, BSMI
ISO Certification ISO 9001:2000 Certification No. 06-1080 Issued by TüV USA ©2008 Microscan Systems, Inc. All rights reserved. Specifications subject to change. Product specifications are given for typical performance at 25°C (77°F) using grade A labels. Performance characteristics may vary at high temperatures or other environmental extremes. Warranty–One year limited warranty on parts and labor. Extended warranty available.
Quadrus EZ Reader User’s Manual
A-3
Page 308
Electrical Specifications
Appendix B, Electrical Specifications Maximum Operating Power: CCD: 10Watts; CMOS: 8watts Power Input: 10 to 28VDC, 200mV p-p max. ripple; 346 mA @24VDC (typ.) CCD; 260 mA @24VDC (typ.) CMOS Trigger, New Master, Input 1: 4.5 to 28VDC (12mA @24VDC) (optoisolated) Outputs (1,2,3): 1 to 28VDC rated (ICE <100mA @24VDC, current limited by user) (optoisolated)
Host 25-pin Connector Pin
All
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 a
AuxRS232
I/O
RS-232
Out In Out In Out
TxD RxD RTS Aux TxD CTS Aux RxD
RS-422/485
Ethernet
RxD (+) In TxD (–) Out
RxD (+) In RxD (–) In
RxD (–) In
TxD (–) Out
TxD (+) Out
TxD (+) Out
Chassis ground
Output 1 (+) Signal groundb Output 2 (+) Trigger (–) Trigger (+) Default config.c Input 1 (+)
Output 3 (+)
Out In In In In
Out
Power groundd Power +10 to 28 VDC
In
Output 1 (–) Output 2 (–) Output 3 (–) Input 1 (–) New master (–) New master (+)
Out Out Out In In In a. Chassis ground: Used to connect chassis body to earth ground only. Not to be used as power or signal return. b. Signal ground: Used for communication and signal line grounds only. Not to be used as power or chassis return. c. The default is activated by connecting pin 11 to ground pin 7. d. Power ground: Used for power return only. Caution: If using your own power supply, verify correct connection of power and ground lines. Incorrect connections or use of “Chassis ground,” “Power ground,” and “Signal ground” lines could cause equipment and/or software failure.
A-4
Quadrus EZ Reader User’s Manual
Page 309
Appendices
Optoisolator Outputs Optoisolator circuits can transfer pulses between the reader and peripherals with no direct connection with the reader’s internal circuitry. However, not every optoisolator configuration provides complete isolation. The following diagrams show both fully optoisolated and nonoptoisolated circuits. They are only examples and do not represent all the possible wiring configurations. Iload=5mA
Iload=50mA
Iload=100mA
VOutOn
0.5V
0.5V
1.0V tOn-Typ
5mS
0.7mS
0.8mS tOff-Typ
5µS
5µS
5µS
Outputs (+)
Scanner Output
ILoad Outputs (–)
Output Circuit Examples Fully Optoisolated This circuit is fully optoisolated and the recommended configuration. It allows the user to apply 1 to 28 VDC to the circuit. Caution: The maximum current that can pass through the optoisolator is 100mA.
Host
Isolated Reader Power (+)
1 to 28 V Scanner
Outputs (+)
Output
Input Outputs (–) Power ground
Not Optoisolated, Reader Grounded In this diagram, power is applied externally, but the reader’s power ground is used to complete the circuit. This setup involves some risk to the optoisolator if excessive voltages are applied. Caution: The maximum current that can pass through the optoisolator is 100mA.
Non-isolated Reader
Host Power (+) 1 to 28 V
Scanner
Outputs (+)
Output
Input Outputs (–)
Power ground
Quadrus EZ Reader User’s Manual
A-5
Page 310
Electrical Specifications
Additional Isolated Output Circuit Examples Secondary Relay 1 to 28 V
Isolated Reader
PLC Power +
RELAY
Isolated Reader Power + Scanner
Scanner Output
Outputs (+)
PLC
Input
Outputs (+)
Outputs (–)
Output
V
PLC GND
Power ground Outputs (–) Power ground
A-6