Page 291
Output Format
Length Definition:
Specifies the length of the decoded symbol allowed to occupy this location in multi-symbol output. Note: To filter or order a symbol, the symbol must meet all requirements of the selected filter index.
Serial Cmd:
<K744,filter number,symbology type,length,wildcard,placeholder,data, unused,database index>
Default:
0
Options:
0 to 64
Wildcard Definition:
This is the character to be used in the data output field when performing a data filter comparison. The wildcard character represents the end of matching, and allows for variable lengths of symbol output.
Serial Cmd:
<K744,filter number,symbology type,length,wildcard,placeholder,data, unused,database index>
Default:
“ * “ = 2A (hex)
Options:
Any ASCII input in the form of a pair of hex characters. Example: 2A = * 00 = disabled
Placeholder Definition:
The placeholder character requires a character to be present, but does not compare the data value.
Serial Cmd:
<K744,filter number,symbology type,length,wildcard,placeholder,data, unused,database index>
Default:
“ ? ” = 3F (hex)
Options:
Any ASCII input in the form of a pair of hex characters. Example: 3F = ? 00 = disabled
Quadrus EZ Reader User’s Manual
14-11
Page 292
Output Filter Configuration
Data Definition:
This is the data string to be used when comparing symbol data for output filtering and ordering. This data string may also contain wildcard and placeholder characters to facilitate matching. Remember that in order to filter or order symbol data, it must meet all the requirements of the selected filter index. Examples: • Filter data = “123*”. This will match data strings of “123”, “123456”, and “123ABC”, but not “12”. • Filter data = “123*AB?C”. This will be interpreted as “123*”. • Filter data = “123?”. This will match “1234” and “123A”, but not “123”, “12345”, or “1234C”. • Filter data = “123?A”. This will match “1234A” and “123BA”, but not “123”, “1234C”, or “1234ABCD”. • Filter data = “123?A?”. This will match “1234AB” and “123BAT”, but not “1234A” or “123BATS”. • Filter data = “12??*”. This will match “1234”, “123456”, and “123ABC”, but not “12” or “123”. • Filter data = “123?A*”. This will match “1234A”, “123BA”, and “123BATS”, but not “1234” or “1234C”.
Serial Cmd:
<K744,filter number,symbology type,length,wildcard,placeholder,data, unused,database index>
Default:
00
Options:
Any ASCII input in the form of a pair of hex characters. Examples: 41422A = AB* Data [0] = null represents string matching disabled.
Database Index Definition:
The index of the database entry that decodes a given symbol must equal this setting for filtering to occur. A setting of 0 allows any database index for this filter entry.
Serial Cmd:
<K744,filter number,symbology type,length,wildcard,placeholder,data, unused,database index>
Default:
0 (any index)
Options:
0 to 10
14-12
Quadrus EZ Reader User’s Manual
Page 293
Output Format
Ordered Output Filter Definition:
Number of Filters refers to the number of active output filters. 0 disables all output filters. Any non-zero numeral will enable filtering to be performed using the filter indexes covered by this value. For example, if the number of filters is 1, then only filter index # 1 will be applied. If the number of filters is 2, then only filter index # 1 and filter index # 2 will be applied, etc.
Serial Cmd:
<K745,number of filters>
Default:
0
Options:
0 to 10
Quadrus EZ Reader User’s Manual
14-13
Page 294
Ordered Output Filter
14-14
Quadrus EZ Reader User’s Manual
Page 295
15 Ethernet Contents Step 1 Setup............................................................................................................................... 15-2 Step 2 Preliminary Steps ............................................................................................................ 15-3 Step 3 Communicating in Ethernet............................................................................................. 15-7 Step 4 Ethernet Application ........................................................................................................ 15-8
This section only applies to Quadrus EZ readers that are designed for Ethernet connectivity. While it is possible to connect the Quadrus EZ directly to your host computer by Ethernet TCP/IP, typical usage is in a networked environment with either a switch or router. Note: The characters NULL <> and , can only be entered through embedded menus, not through ESP or serial commands.
Quadrus EZ Reader User’s Manual
15-1
Page 296
Step 1, Setup For Ethernet setup, you will need: • A Quadrus EZ Ethernet-ready reader with application code -14 or newer and ESP version 1.2 or newer. • An IB-151 Ethernet/USB interface. • An IB-150 kit (interface and cable). • An Ethernet switch or router. RJ45 Ethernet cables (use a crossover cable if connecting directly to the host computer). • A Laptop or Desktop host computer with Ethernet connectivity to a network and Windows 98 or 2000.
15-2
Quadrus EZ Reader User’s Manual
Page 297
Ethernet
Step 2, Preliminary Steps 1. Plug the IB-151 interface into the Quadrus EZ. 2. Plug the IB-150 kit cable into the IB-151 and make the connection to the host computer and power supply. 3. Connect the Ethernet cables from the IB-151 interface to the switch or router and from the switch or router to the host computer. The “NETWORK STATUS” LED on the side of the Quadrus EZ should light green when the Ethernet cable is connected. 4. Start ESP and establish communication with the host computer through the RS-232 host port. There are three ways the Quadrus EZ can connect to a host by Ethernet: • Assigning a network address. • Using the reader’s default IP address. • Using DHCP (Dynamic Host Configuration Protocol) assignment.
Quadrus EZ Reader User’s Manual
15-3
Page 298
Assigning a Network Address This procedure will configure the reader to work with the TCP/IP configuration of the host computer. Note: This is only a temporary solution since the preferred method is to receive IP, subnet, and gateway (if necessary) from your IS department. If an IP address has been assigned to the reader by the IS department (the most appropriate method), skip steps 1-3 below. 1. Determine the host computer's IP address on the host's network: Go to the Windows Start menu, select Run, type command and press Enter. a) On Win2K computers, at the command prompt, type ipconfig. b) On Win98 computers type winipcfg and select the Ethernet Interface in the drop-down box. 2. To the IP Address of the host computer add '1' to the last decimal value. This will be the IP address that you will assign to the reader. For example, if the host computer's IP is 123.234.1.25, the reader's IP will be 123.234.1.26. 3. To verify that the new IP address is available, go back to the command prompt and type in the command: ping [reader IP address]. For example: ping 123.234.1.26. If the ping program responds with “Request timed out” message, then the IP address can probably be used temporarily. If you get a “Reply” message, then that address has already been assigned to another device and you need to contact your IS department for an available IP address. 4. Do Receive Reader Settings. 5. From the ESP Communications menu, enter your reader's new IP address, for example, 123.234.1.26, and save this to the reader. The reader is now configured with an IP address that will allow communication with the host computer. In the ESP Communications menu, you should see the following: 6. Go to Step 3, Communicating in Ethernet.
15-4
Quadrus EZ Reader User’s Manual
Page 299
Ethernet
Using the Reader's Default IP Address Note: This procedure is only used when the reader is directly connected to the computer. Also, this is only a temporary solution since the preferred method is to receive IP, subnet, and gateway (if necessary) from your IS department. 1. Determine the host computer's IP address on the host's network: Go to the start menu, select Run, type command and press Enter. a) On Win2K computers, at the command prompt, type ipconfig. b) On Win98 computers type winipcfg and select the Ethernet Interface in the drop-down box. 2. Note the IP Address of the host computer. 3. At the Windows command prompt, type route add 192.168.0.100 [host computer IP] and press Enter. This adds the reader’s IP to the computers routing table. 4. At the Windows command prompt, type route print and press Enter. The command prompt should display something similar to the following:
5. Look for the “192.168.0.100” in the Network Destination column. If it does not appear here, contact your IS department. 6. Go to Step 3, Communicating in Ethernet.
Quadrus EZ Reader User’s Manual
15-5
Page 300
Using DHCP to Configure the Reader This assumes that the Quadrus EZ is connected to a network on which resides a DHCP server. RS-232 configuration is required to enable the reader's DHCP client (default “IP address mode” setting is “static”, which disables DHCP). 1. Do Receive Reader Settings. 2. Under Network in the ESP Communications menu, double click on IP Address Mode and change Static to DHCP. 3. Right click on the Communications menu and do Save to Reader/Send no Save. 4. Do Receive Reader Settings. 5. Notice that the network will have assigned new numbers to the IP Address, Subnet, and Gateway, as shown here: (If the numbers have not changed, contact your IS department.) 6. Go to Step 3, Communicating in Ethernet.
15-6
Quadrus EZ Reader User’s Manual