Appendices CMOS Focal Distance, FOV, DOF and Symbol Size by Lens Type Focal Distance Inches mm 3.50 3.75 4.00 4.25 4.50 4.75 5.00
88.9 95.3 101.6 108.0 114.3 120.7 127.0
2.25 3.00 4.00 5.00 6.00 7.00 8.00 9.00 10.00
57.2 76.2 101.6 127.0 152.4 177.8 203.2 228.6 254.0
2.00 3.00 4.00 5.00 6.00 7.00 8.00 9.00 10.00
50.8 76.2 101.6 127.0 152.4 177.8 203.2 228.6 254.0
2.50 3.00 4.00 5.00 6.00 7.00 8.00 9.00 10.00
63.5 76.2 101.6 127.0 152.4 177.8 203.2 228.6 254.0
Field of View Depth of Field Inches mm Inches mm Narrow Lens 0.34 8.6 0.10 2.5 0.40 10.2 0.10 2.5 0.46 11.7 0.10 2.5 0.51 13.0 0.10 2.5 0.56 14.2 0.10 2.5 0.61 15.5 0.20 5.1 0.67 17.0 0.20 5.1 Medium Lens 0.24 6.1 0.10 2.5 0.60 15.2 0.20 5.1 0.80 20.3 0.50 12.7 0.98 24.9 0.80 20.3 1.16 29.5 1.80 45.7 1.32 33.5 2.00 50.8 1.50 38.1 2.00 50.8 1.70 43.2 3.40 86.4 1.86 47.2 3.40 86.4 Wide Lens 0.50 12.7 0.10 2.5 0.75 19.1 0.50 12.7 0.98 24.9 1.00 25.4 1.17 29.7 1.80 45.7 1.40 35.6 2.20 55.9 1.60 40.6 3.40 86.4 1.82 46.2 3.60 91.4 1.99 50.5 3.60 91.4 2.26 57.4 6.00 152.4 Extra Wide Lens 1.09 27.7 1.00 25.4 1.46 37.1 1.00 25.4 1.88 47.8 1.00 25.4 2.27 57.7 2.20 55.9 2.64 67.1 3.80 96.5 3.05 77.5 5.00 127.0 3.47 88.1 5.20 132.1 3.83 97.3 4.80 121.9 4.24 107.7 8.00 203.2
Quadrus EZ Reader User’s Manual
Symbol Element Size Inches mm .005 .005 .005 .005 .005 .0075 .0075
0.127 0.127 0.127 0.127 0.127 0.191 0.191
.005 .0075 .0075 .010 .015 .015 .015 .020 .020
0.127 0.191 0.191 0.254 0.381 0.381 0.381 0.508 0.508
.005 .0075 .010 .015 .015 .020 .020 .020 .030
0.127 0.191 0.254 0.381 0.381 0.508 0.508 0.508 0.762
.015 .015 .015 .020 .030 .030 .030 .030 .040
0.381 0.381 0.381 0.508 0.762 0.762 0.762 0.762 1.016
A-27
Page 332
Rapid Capture Mode
Appendix K, Rapid Capture Mode In rapid capture mode, from one to eight captures can be specified along with time delays between captures. In this mode the only built-in delay is the time for image capture and transfer. After the initial capture has been transferred, decoding begins and is processed simultaneously with and independently of subsequent captures. The key features of Rapid are: • There is no wait between captures for processing • From one to eight captures can be user-defined • Time delays between captures can be individually user-defined Rapid Capture is useful when: • Reading sets of up to 8 symbols • “Extending” the field of view • In very high-speed applications • Switching by number of captures in dual camera applications • Precise timing and spacing are needed
Single Capture When you first load ESP, the default for capturing is Rapid Capture and Number of Captures set to 1. This is the same as “single shot” and will work well with many moving applications. When FOV Symbol objects are tightly spaced, Rapid Capture set to Last Frame is the preferred setup. In the sketch to the above, a trigger is used to time the capture to occur when the symbol is in the center of the FOV.
A-28
Quadrus EZ Reader User’s Manual
Page 333
Appendices
Multiple Captures In many applications, you can improve opportunities for good reads by increasing the number of captures. The sketches below show dynamic multiple captures with no user-defined time delays added between them. However, since a built-in or “overhead” capture time (15mS for CCD and 30mS for CMOS) occurs after each capture, some spacing between captures will be noticeable in higher speed applications.
• An ideal setup would look like this where overlapping symbols fall within or mostly within the FOV.
Quadrus EZ Reader User’s Manual
• This shows an acceptable pattern where at least one symbol can be expected to fall within the FOV.
• The spacing here is not acceptable since it is too wide to guarantee that any of the symbols will fall within the FOV.
A-29
Page 334
Object Detector
Appendix L, Object Detector In a typical operation, a reader will wait for symbol data only during a triggered read cycle. A read cycle is initiated by a “trigger” and can be in the form of a serial command from the host (internal trigger) or a signal from an object detector (external trigger). When an object detector (also called a sensor, package detector, etc.) is used, it is set up so that its beam will bounce off the approaching object and the resulting pulse will be sent to the reader to begin the read cycle. Typically, a detector is positioned so that it will detect the presence of an object before its symbol can be read. An object detector is mounted in almost any position relative to the object as long as (1) the object passes within range of the detector and (2) direct or reflected light from the detector does not interfere with the reader’s reception. As the item continues to move down the line, its symbol moves into the reader beam and is read by the reader.
Object Detector Operation
A-30
Quadrus EZ Reader User’s Manual
Page 335
Appendices
Appendix M, Operational Tips Cleaning The Quadrus EZ has a hard coated window that should only be cleaned with Alcohol (100% Isopropyl).
Mounting When mounting the Quadrus EZ, do not insulate the stand mount. The bottom of the reader is the hottest part of the reader and metal to metal contact is needed for heat dissipation.
Quadrus EZ Reader User’s Manual
A-31
Page 336
Embedded Menus
Appendix N, Embedded Menus In addition to ESP, you can also use a communications menu such as HyperTerminal to establish communication with Microscan’s embedded menus.1 1. With your host connected to the Quadrus EZ, set your host communications settings as follows: 115.2K baud, 8 Data Bits, 1 Stop Bits, and None Parity. 2. Set Flow Control to None. 3. Make the communications port selection. (Usually COM 1 for Windows OS.) Upon connection, send a <D> command to bring up the main menu. Menu navigation commands are case sensitive. Use the space bar or N to advance to the next item, CR (return key) to select a highlighted item, B to return to the previous item, M to return to the previous menu, and ESC to return to the Main menu or to exit the program. When exiting the program, you will be prompted to save your active settings for power up (Y or N). Typing Y will be equivalent to saving with a <Z> command.
1. If you are using HyperTerminal, you may find that the initial screen is not visible when you call up the program with the <D> command. If this occurs, exit the embedded menu with an ESC, E, and N sequence and repeat A-32 the <D> command. Quadrus EZ Reader User’s Manual
Page 337
Appendices
Appendix O, Interface Standards Interface Standards, established by the Electronic Industries Association (EIA), specify such things as the signaling voltage levels, maximum cable lengths, and number of drivers. With Microscan devices, selection of interface is made by pin assignment and, in the case of the host communications, by software switching between RS-232 and RS-422. Microscan devices use RS-232, RS-422, and RS-485 multidrop.
RS-232 RS-232 defines an interface between two devices such as, for example, the reader and host. It differs from the other interfaces by dedicating individual pins to specific functions and by requiring both devices to share a common ground line. Since both device chassis are connected to a common ground, a ground loop potential and the possibility of noise interference exists. Therefore cable lengths are limited to a maximum of 50 feet (19.7m). Despite being the most limited, this interface is used frequently because of the large installed base of RS-232 equipment.
RS-422 RS-422, unlike RS-232, measures signals deferentially; that is, the receiver looks at the potentials between the two receive (or transmit) wires rather than the potential between signal and ground. As a result, cables, if shielded, can be up to 4000 feet (1219m) in length. Like RS-232, RS-422 communication is designed for only two devices on a single line and must have a common ground. It can be used wherever RS-232 is used.
RS-485 RS-485, like RS-422, can transmit up to 4000 feet (1219 m) using differential voltages but unlike RS-422, its transmitters are turned off until a request for data is received from the host. RS-485 is used exclusively in multidrop protocol.
Ethernet Ethernet is supported for 10Mbps per second with packets between 64 and roughly 1500 bytes in length. A 6-byte address is used, which is divided into a 3-byte vendor ID and a 3byte vendor-defined field. Ethernet manufacturers are assigned a unique vendor ID, and are then responsible for insuring that all of their devices have unique addresses in the last 3 bytes.
Quadrus EZ Reader User’s Manual
A-33
Page 338
Multidrop Communications
Appendix P, Multidrop Communications This appendix describes the rules for setting up a concentrator or controller to communicate with a reader in standard Multidrop protocol. The diagram to the right shows a typical Multidrop network in which 1 to 50 readers can comHost municate with a host via an intermediary device, a concentrator or a controller.
Polling Sequence Polled Protocol Concentrator Data that is transmitted to the host (symbol Multidrop ONLY data, noread messages, counters, etc.) via RS-485 Interface concentrators is solicited by poll requests from the host. The polling sequence example by poll address 1E (ASCII hex value for Reader 02) and a REQ Reader 01 (request). The reader responds by first transmitting its own address, 1E, followed by a STX Reader 02 (start of text) character, and then the data. Next Reader 03 it transmits an ETX (end of text) character and an LRC (longitudinal redundancy check) character. Multidrop If the concentrator (or controller) receives the data from the reader and is able to validate it with an LRC calculation, it responds with an ACK (acknowledgment). If the reader in turn receives the ACK, the reader ends this successful exchange with a RES (reset). Start of Sequence
Concentrator Reader 02
End of Sequence
RES 1E REQ
ACK 1E STX DATA ETX LRC
RES
Polling Sequence Polling Reset • If the reader has no information, it responds to a poll request by transmitting a RES (reset). • If the reader receives a NAK instead of the ACK after transmitting its data string, it will re-attempt to send the data string up to three times. If the reader still does not receive an ACK, it will send a RES (reset) and discard the data in its buffers. • If the reader transmits data to the concentrator and the concentrator responds with an ACK or NAK, but the reader doesn’t receive the concentrator’s response, the reader will timeout and send a REQ to the concentrator and request another response. If after three retries (the number of times it transmits a REQ to the concentrator) the reader receives no response, it ends the transmission with a RES (reset). A-34
Quadrus EZ Reader User’s Manual
Page 339
Appendices
Select Sequence Unlike poll requests, select commands always originate from the host and consist of serial configuration or operation commands to devices that are configured in Multidrop. The reader complies with the command when it is polled during the cycle. Start of Sequence
End of Sequence
Concentrator RES 1F REQ Reader 02
STX <T>ETX LRC 1F ACK
RES 1F ACK
Polling Sequence A RES (reset) is the first command in the select sequence. The 1F hex is the select address associated with Reader 02 address. It is followed by a REQ (request). The reader responds with its own select address, 1F hex, and an ACK (acknowledge). The concentrator then transmits an STX (start of text), the data (in this case a <T>), an ETX (end of text), and an LRC character. The reader replies by transmitting its own address, followed by an ACK, acknowledging receipt of the command. Upon receipt of an ACK, the concentrator concludes the successful exchange with a RES. In the example above, the reader only acknowledges a trigger counter request from the concentrator. It does not respond to the trigger counter request until a subsequent poll. For example, if the reader’s trigger count was 12 at the time the trigger counter request was received, on a subsequent poll it would send 02T/00012. (The 02 at the beginning of the string is the reader’s address.) Select Reset If the reader receives bad data from the concentrator, it transmits a SEL (its select address) and a NAK to the concentrator. The concentrator re-transmits the data up to three times. The concentrator will end the sequence with a RES (reset) if no ACK is received.
Quadrus EZ Reader User’s Manual
A-35
Page 340
Multidrop Communications Multidrop Addresses Multidrop Address 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
A-36
Poll Character ASCII HEX ^\ 1C ^^ 1E SP 20 " 22 $ 24 & 26 ( 28 * 2A , 2C . 2E 0 30 2 32 4 34 6 36 8 38 : 3A < 3C > 3E @ 40 B 42 D 44 F 46 H 48 J 4A L 4C
Select Character ASCII HEX ^] 1D ^1F ! 21 # 23 % 25 ' 27 ) 29 + 2B 2D / 2F 1 31 3 33 5 35 7 37 9 39 ; 3B = 3D ? 3F A 41 C 43 E 45 G 47 I 49 K 4B M 4D
Multidrop Address 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50
Poll Character ASCII HEX N 4E P 50 R 52 T 54 V 56 X 58 Z 5A \ 5C ^ 5E ` 60 b 62 d 64 f 66 h 68 j 6A l 6C n 6E p 70 r 72 t 74 v 76 x 78 z 7A | 7C ~ 7E
Select Character ASCII HEX O 4F Q 51 S 53 U 55 W 57 Y 59 [ 5B ] 5D _ 5F a 61 c 63 e 65 g 67 i 69 k 6B m 6D o 6F q 71 s 73 u 75 w 77 y 79 { 7B } 7D D 7F