Page 21
Quick Start
Locate by ESP 1. In the EZ menu, click the Locate button to enable the X-pattern.
2. You will see the X-pattern in front of the reader. 3. Center the X-pattern over the symbol you want to read. 4. Click the Stop button to end the locate mode.
Quadrus EZ Reader User’s Manual
1-9
Page 22
Calibrate Settings
Step 8, Calibrate Settings Quadrus EZ image settings can be adjusted automatically for optimum readability by either the EZ setup button or ESP. During the calibration routine, the reader will flash its LEDs while searching through various IP (image processing) settings and matching them with the highest read rates. Upon successful completion of this routine, a green LED pattern will flash brightly and illuminate the symbol. If unsuccessful, the reader will emit 5 short beeps and stop searching.
Calibrate by EZ Button 1. Hold down the EZ setup button about 2 seconds and release when you hear two short beeps. 2. The reader will search through various IP settings and match them with the highest read rates. Note: To end all EZ button functions, press the EZ button and quickly release.
Calibrate by ESP 1. Click the Calibrate button. 2. The reader will search through various IP settings and match them with the highest read rates. A successful calibration will display a green frame around the symbol. Following this, a message, “Uploading all reader parameters” will appear. After a moment the symbol’s data and related features will be presented under the “Symbol Information” box below the image display window.
Calibrate by Serial Command Send <op,6,1> to begin calibration. Send <op,6,0> to end calibration.
1-10
Quadrus EZ Reader User’s Manual
Page 23
Quick Start
Step 9, Perform Readability Test This test will let you know the percent of good reads per captures achieved by the reader.
Testing by EZ Button 1. To start the read rate test, hold down the EZ setup button about 3 seconds until you hear three short beeps and see the alternating IP and finder pattern LEDs.
20%, 40%, 60%, 80%, 100% these LEDs are only active while the reader is in a read rate test and represent the percentage of good reads per images captured.
While the symbol is being decoded, the read rate LEDs will indicate the corresponding read rate percentage on the side of the unit. 2. To end the read rate test, press the EZ button and quickly release.
Good Read Percentage
Testing by ESP 1. Click the Test button to start the read rate test and Stop to end it. If your symbol has been successfully decoded, its data and related features will be presented under “Symbol Information.” Also, while the symbol is being decoded, the read rate LEDs will indicate the corresponding read rate percentage on the side of the unit as shown above. 2. To end the test, click the Stop button.
Testing by Serial Command You can also start a test with the <C> or <Cp> command and end it with the <J> command.
Quadrus EZ Reader User’s Manual
1-11
Page 24
Applications
Step 10, Applications To make setup changes to the Quadrus EZ, click the App Mode button.
From here you can make changes in the configuration files that appear on the second row of icons. You can also do the following: • Send or Receive commands by clicking the Send/Recv button. • Make changes to Camera options by clicking the Camera button. • Access the Terminal window to see data or entering serial commands by clicking the Terminal button. • Review status settings or make changes to operational commands by clicking the Utilities button. • Format data for output by clicking the Output Format button. For details, see ESP Help in the pulldown menu. The window on the left represents the tree control. The window on the right is where image captures are displayed.
1-12
Quadrus EZ Reader User’s Manual
Page 25
Quick Start
Step 11, Make Menu Changes and Save in ESP To make changes to a configuration setting:
1. Left click on the + to expand tree. 2. Double click on parameter and click once in selection box to view options. 3. Place your cursor in the selection box, scroll down to the setting you want to change and click once on the setting. 4. Left click again on the open screen to complete the selection.
5. Right click on the open screen and select Save to Scanner to implement the command in the reader.
You have 3 choices for saving: • Send, No Save. Changes will be lost when power is recycled. Caution: This only saves certain commands to memory. • All other commands are saved for power-on, the same as the Send and Save option. • Send and Save. This activates all changes in current memory and saves to the scanner for power-on. • Send and Save as Customer Settings. Same as above, except that these settings are saved to a special section of NOVRAM. Note: This option must be enabled under the Options pull down menu before it will be available as a save option.
Quadrus EZ Reader User’s Manual
1-13
Page 26
Make Menu Changes and Save in ESP
Video Output Option You can connect a remote video monitor (RS-170/monochrome, non-interlaced) via the video output port on the back of the Quadrus EZ Reader and view live video or triggered events such as a good read, no read, or slide show of on-going captures.
To Enable Live Video: Press and hold the EZ button until you hear a series of 4 beeps.
Video Output
Video Input
Note for CCD readers: When Live video mode is active, in order to synchronize with the video format, a shutter time of 1/1000 is the lowest shutter speed setting that can be applied to the camera settings. Slower shutter speeds will disable the video output. When connected to a remote video with Live video mode active, the monitor screen is a close representation of the FOV. This allows you to visually verify that a symbol is within the FOV and the X-pattern is centered over it.
Note: During normal read cycle operations, the X-pattern will not be present unless enabled by <K750,,1> or by ESP.
Video Input Option You can connect an external camera (RS-170/monochrome non-interlaced, progressive format, 512 lines, 30 fps) for streaming captures into the Quadrus EZ Reader. Note: Power to an external camera is not supplied by the Quadrus EZ Reader.
1-14
Quadrus EZ Reader User’s Manual
Page 27
2 Communications Contents Communications by ESP .............................................................................................................. 2-2 Communications Serial Commands.............................................................................................. 2-3 RS-232/422 Host Port................................................................................................................... 2-4 RS-232 Auxiliary Port................................................................................................................. 2-11 Network...................................................................................................................................... 2-21 Preamble.................................................................................................................................... 2-24 Postamble .................................................................................................................................. 2-25 Response Timeout..................................................................................................................... 2-26 LRC Status................................................................................................................................. 2-27 Aux Port System Data Status .................................................................................................... 2-28
This section tells how to set up communications parameters with the host and an auxiliary terminal. With Microscan’s ESP (Easy Setup Program), configuration changes can be made in the ESP menus, then sent and saved to your reader. The user can also send serial commands to the reader via the ESP’s Terminal window. Note: The characters NULL <> and , can only be entered through embedded menus, not through ESP or serial commands.
Quadrus EZ Reader User’s Manual
2-1
Page 28
Communications by ESP
Communications by ESP
Click this button to bring up the Applications menu.
Click this button to bring up the Communications parameters.
To open nested options, single-click the +. To change a setting, double-click the setting and use your cursor to scroll through the options.
2-2
Quadrus EZ Reader User’s Manual
Page 29
Communications
Communications Serial Commands Host Port Connections Host Port Protocol Host 232/422 Status Auxiliary Port Daisy Chain Autoconfigure Daisy Chain ID Ethernet Configuration Preamble Postamble Response Timeout LRC Aux Port System Data Status
Quadrus EZ Reader User’s Manual
<K100,baud rate,parity,stop bits,data bits> <K140,protocol> <K102,host 422> <K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain ID status,daisy chain ID> <K150DAISY> <K151,daisy chain reader #,daisy chain reader ID> <K125,IP address,subnet address,gatewayaddress,IP address mode,primary TCP port,video TCP port> <K141,status,preamble characters> <K142,status,postamble characters> <K143,response timeout> <K145,status> <K146,aux port system data>
2-3
Page 30
RS-232/422 Host Port
RS-232/422 Host Port The host port can be configured with RS-232 and RS-422 connections.
Host Port Connections These settings define the basic transmission speeds and digital standards that ensure common formatting.
Baud Rate, Host Port Usage:
Can be used to transfer data faster or to match host port settings.
Definition:
The rate at which the reader and host transfer data back and forth.
Serial Cmd:
<K100,baud rate,parity,stop bits,data bits>
Default:
115.2K
Options:
0 = 600 3 = 4800 6 = 38.4K
1 = 1200 4 = 9600 7 = 57.6K
2 = 2400 5 = 19.2K 8 = 115.2K
Parity, Host Port Usage:
Only changed if necessary to match host setting.
Definition:
An error detection routine in which one data bit in each character is set to 1 or 0 so that the total number of 1 bits in the data field is even or odd.
Serial Cmd:
<K100,baud rate,parity,stop bits,data bits>
Default:
None
Options:
0 = None
1 = Even
2 = Odd
Stop Bits, Host Port Usage:
Only changed if necessary to match host setting.
Definition:
One or two bits added to the end of each character to indicate the end of the character.
Serial Cmd:
<K100,baud rate,parity,stop bits,data bits>
Default:
One
Options:
0 = One
2-4
1 = Two
Quadrus EZ Reader User’s Manual