The text of a manual · part 2 of 37
Quadrus EZ Reader User's Manual, pages 11 to 20
Pages 11 to 20 of 366
The original document is the PDF (2.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Microscan EZ 6700 EX
Page 11
Introduction
Warning and Caution Summary WARNING LED LIGHT DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS CLASS 1M LED PRODUCT Light Output: 648 cd. Wavelength: 464 nm; 518 nm; 635 nm. IEC 60825-1:1993+A1:1997+A2:2001
• Viewing the Quadrus EZ’s LED output with optical instruments such as magnifiers, eye loupes, or microscopes within a distance of 100 mm could cause serious eye injury. • Maximum LED light output: 648 cd. • Wavelength: 464 nm; 518 nm; 635 nm. • Location of the Quadrus EZ’s LED aperture window:
LED Aperture Window
• CAUTION: Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.
Quadrus EZ Reader User’s Manual xi
Page 12
Statement of Agency Compliance
Statement of Agency Compliance This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna • Increase the separation between the equipment and receiver • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected • Consult the dealer or an experienced radio/TV technician for help For connection to a UL-listed direct plug-in power unit marked Class II and rated 10 to 28 VDC at 10 watts (CCD) or 8 watts (CMOS), or greater if using electrical accessories. European models must use a similarly rated Class I or Class II power supply that is certified to comply with standard for safety IEC 60950.
Approvals This equipment is in compliance or approved by the following organizations: • CDRH (Center for Devices & Radiological Health) • FCC (Federal Communications Commission) • CE (Conformité Européenne) • BSMI (Bureau of Standards, Metrology and Inspection)
xii
Quadrus EZ Reader User’s Manual
Page 13
1 Quick Start Contents Step 1 Check Required Hardware................................................................................................ 1-2 Step 2 Connect the System.......................................................................................................... 1-3 Step 3 Position Reader and Symbol............................................................................................. 1-4 Step 4 Install ESP......................................................................................................................... 1-5 Step 5 Select Model ..................................................................................................................... 1-6 Step 6 Select Communications Protocol ...................................................................................... 1-7 Step 7 Locate the Symbol in the FOV .......................................................................................... 1-8 Step 8 Calibrate Settings........................................................................................................... 1-10 Step 9 Perform Readability Test................................................................................................ 1-11 Step 10 Applications.................................................................................................................. 1-12 Step 11 Make Menu Changes and Save in ESP....................................................................... 1-13 Video Output Option .................................................................................................................. 1-14
This chapter is designed to get your reader up and running quicklyusing the reader’s EZ button or ESP (Easy Setup Program) so the user can get a sense of its capabilities and test sample symbols. Detailed setup information for installing the reader into the actual application can be obtained in the subsequent chapters. In addition to ESP, you can send commands to your reader by serial commands and through the reader’s embedded menus.
Quadrus EZ Reader User’s Manual
1-1
Page 14
Check Required Hardware
Step 1, Check Required Hardware To get started with just the EZ Button You will need: • A Quadrus EZ Reader (1), FIS 6700-XXXX. • An IB-150 Kit, 98-000040-02, which includes a cable, 61-000034-02, and the IB-150 Interface Box (2), 99-000008-02. • A Power Supply (3), 97-100004-15 (90-264 VAC, 24VDC).
If connecting to a host by RS-232 You will also need the following: • A host computer with either a terminal communications program or Microscan’s ESP, which runs under Windows operating system, Windows 98 or higher. • An IB-150 Host Communications Cable (6), 61-000034-02 (25-pin socket to 9-pin socket). • Object Detector (5) (optional), 99-000017-01.
1
4 7
2 HOST
READER AUX PORT
6
If connecting to a host by TCP/IP See Chapter 15, Ethernet. 3
5
Hardware Configuration
Caution: Be sure that all cables are connected BEFORE applying power to the system. Always power down BEFORE disconnecting any cables.
1-2
Quadrus EZ Reader User’s Manual
Page 15
Quick Start
Step 2, Connect the System You can connect the Quadrus EZ by EZ button, RS-232, or TCP-IP (Ethernet).
Connecting for EZ Button Setup without a Host • Connect the Quadrus EZ Reader to the IB-150 Kit, 98-000040-02. • Connect Power Supply. • Apply power to the reader.
Connecting by RS-232 • Connect the reader to the IB-150 Kit, 98-000040-02. • Connect the IB-150 Host Communications Cable, 61-000034-02, to the host and the host connector on the side of the IB-150 interface box. Note: When wiring the interface box to a host with a 25-pin host connector, cross pins 2 and 3. When wiring the interface box to a host with a 9-pin host connector, do NOT cross pins 2 and 3. 1. Connect power supply.
1
25
Side View of IB-150 showing Host 25-pin Socket Connection
2. Apply power to the reader.
Connecting to a Host by TCP/IP See Chapter 15, Ethernet.
Quadrus EZ Reader User’s Manual
1-3
Page 16
Position Reader and Symbol
Step 3, Position Reader and Symbol • Position the reader at the focal distance recommended on the back of the reader, for example FD = 4”. • Tip the reader relative to the symbol to avoid the glare of direct (specular) reflection. The case parting line should be perpendicular to the plane of the symbol by either pitching the symbol or the reader as shown. • Position the reader in a place devoid of sunlight. • Symbols can be rotated (tilted) in any angle; however, for best results symbols should be aligned with the FOV (field of view).
Parting Line Stand
Focal distance 90°
Reader Position • In the case of linear symbols, aligning the bars in the direction of their movement (“ladder” orientation) will minimize the chances of blurring and produce better reads. • Avoid excessive skew or pitch. Maximum skew is ±30°; maximum pitch is ±30°. Note: For instant setup and validation, the Quadrus EZ can be hand-held or laid on its side; but for accuracy a mounting stand such as the one shown above is recommended.
1-4
Quadrus EZ Reader User’s Manual
Page 17
Quick Start
Step 4, Install ESP ESP stands for Easy Setup Program. ESP provides a quick and easy way to set up and configure your reader.
If installing from a Microscan Installation and Support CD: 1. Insert your Microscan Installation and Support CD in your computer’s CD drive. 2. Choose ESP Software from the main menu. 3. Launch Setup.exe under ESP and follow the prompts.
If downloading from the web: 1. Go to http://www.microscan.com/downloadcenter 2. Create a new “myMicroscan” member account or, if you are already a member, enter your user name and password. 3. Click the Download Software link and extract the latest version of ESP to a directory location of your choice. Note where your ESP.exe file is stored on your hard drive. 4. At the end of the installation process, the following icon will appear on your desktop:
5. Click the ESP icon to start the program.
Quadrus EZ Reader User’s Manual
1-5
Page 18
Select Model
Step 5, Select Model When you start the program, the following menu will appear:
Note: If you need to select another model later, click the Switch Model button. 1. Click the Quadrus EZ button and then click OK. If you do not want to make this selection every time you start ESP, uncheck “Show this window at Startup”. 2. Select the default reader name (Quadrus EZ-1), or type a name of your choice in the Description text field and click OK. 3. Click Yes when this dialog appears:
1-6
Quadrus EZ Reader User’s Manual
Page 19
Quick Start
Step 6, Select Communications Protocol When the Select Protocol dialog appears, choose either RS-232 or TCP/IP (Ethernet) and click Next.
RS-232 1. In the RS-232 dialog, if your communications port is not the default COM1, use the dropdown menu to change your communications port. 2. Click Connect. 3. When connected, the CONNECTED message will appear in a green box in the status bar on the bottom right of the dialog.
4. If the connection fails, click the Autoconnect button, select a different Com port, and try again. Note: If your host settings cannot be changed to match the reader’s settings, check the Force Connect box.
TCP/IP (Ethernet) Both ESP and the reader will need to have TCP/IP addresses assigned. 1. If no address has been assigned to the reader, go to Chapter 15, Ethernet. If your reader has already been assigned IP addresses, enter the IP address in the dialog box. 2. Click Connect.
Tip: If you do not see either the CONNECTED or DISCONNECTED messages at the bottom of your dialog, try expanding the ESP window horizontally.
Quadrus EZ Reader User’s Manual
1-7
Page 20
Locate the Symbol in the FOV
Step 7, Locate the Symbol in the FOV In this step, you move the symbol or the reader so that the “X” pattern is centered over the symbol. It is important that the whole symbol falls within the field of view (FOV) of the reader. (The FOV is what appears in the Locate/ Calibrate window.) Note: Holding the EZ button until you hear 4 beeps enables Live video output (if attached to a monitor).
Locate by EZ Button When not connected to a computer, the EZ setup button will allow you to quickly locate a symbol in the reader’s FOV. 1. Hold down the EZ setup button for about one second and release when you hear one short beep. You will see the blue X-pattern.
EZ Button
2. Center the X-pattern on the symbol. Note: To end all EZ button functions, press the EZ button and quickly release.
1-8
Quadrus EZ Reader User’s Manual