Page 31

Communications

Data Bits, Host Port Usage:

Only changed if necessary to match host setting.

Definition:

One or two bits added to the end of each character to indicate the end of the character.

Serial Cmd:

<K100,baud rate,parity,stop bits,data bits>

Default:

8

Options:

0 = Seven

Quadrus EZ Reader User’s Manual

1 = Eight

2-5

Page 32

RS-232/422 Host Port

Host Port Protocol Usage:

In general, the point-to-point protocols will work well in most applications. They require no address and must use RS-232 or RS-422 communications standards.

Definition:

Protocols define the sequence and format in which information is transferred between the reader and the host, or in the case of Multidrop, between readers and a concentrator.

Serial Cmd:

<K140,protocol>

Default:

Point-to-Point

Options:

0 = Point-to-Point 1 = Point-to-Point with RTS/CTS 2 = Point-to-Point with XON/XOFF 3 = Point-to-Point with RTS/CTS & XON/XOFF 4 = Polling Mode D 6 = User Defined

Point-to-Point (standard) Usage:

Used only with RS-232 or RS-422.

Definition:

Standard Point-to-Point requires no address and sends data to the host whenever it is available, without a request or handshake from the host.

Serial Cmd:

<K140,0>

Point-to-Point with XON/XOFF Usage:

If an XOFF has been received from the host, data will not be sent to the host until the host sends an XON. During the XOFF phase, the host is free to carry on other chores and accept data from other devices. Used only with RS-232.

Definition:

This option enables the host to send the XON and XOFF command as a single byte transmission command of start (^Q) or stop (^S).

Serial Cmd:

<K140,1>

2-6

Quadrus EZ Reader User’s Manual

Page 33

Communications

Point-to-Point with RTS/CTS

Usage:

A reader initiates a data transfer with an RTS (request-to-send) transmission. The host, when ready, responds with a CTS (clear-to-send) and the data is transmitted. CTS and RTS signals are transmitted over two dedicated wires as defined in the RS-232 standard. Used only with RS-232.

Definition:

Point-to-Point with RTS/CTS (request-to-send/clear-to-send) is a simple hardware handshaking protocol that allows a reader to initiate data transfers to the host.

Serial Cmd:

<K140,2>

Point-to-Point with RTS/CTS & XON/XOFF Usage:

Used only with RS-232.

Definition:

This option is a combination of Point-to-Point with RTS/CTS and Pointto-Point with XON/XOFF.

Serial Cmd:

<K140,3>

Polling Mode D Usage:

When in Polling Mode D, an address of 1 is automatically displayed on the configuration menu. However, during transmission, a 1C hex poll address (FS) and a 1D hex select address (GS) are substituted for the 1.

Definition:

Like Point-to-Point, Polling Mode D requires a dedicated connection to the host; but unlike Point-to-Point, it requires an address and must wait for a poll from the host before sending data.

Serial Cmd:

<K140,4>

User Defined Point-to-Point Usage:

Useful for developing custom protocols in polled or unpolled mode.

Definition:

Allows the user to customize the point-to-point protocol.

Serial Cmd:

<K140,6,RES,address,REQ,EOT,STX,ETX,ACK,NAK,from host>

User Defined Address Definition:

User Defined is considered to be in a polled mode only if an address has been assigned.

Serial Cmd:

<K140,6RES,address,REQ,EOT,STX,ETX,ACK,NAK,from host>

Default:

No address

Options:

Any ASCII character except a NULL < , or >.

Quadrus EZ Reader User’s Manual

2-7

Page 34

RS-232/422 Host Port

User Defined Example

Definition:

Example: ACK/NAK protocol can be configured using User Defined. The reader will transmit data to the host, when an ACK is received, it will carry on with its business. If a NAK or response timeout occurs, the reader will resend the data to the host up to 3 more times before aborting. Tip: To use User Defined Point-to-Point, first select Point-to-Point <K140,0> and then User Defined <K140,6>. Example: To select an unpolled ACK/NAK User Defined protocol with LRC disabled, send <K140,0><K140,6,,,,,,,^F,^U><K145,0>. ACK and NAK will be displayed in the menu.

Serial Cmd:

<K140,6,RES,address,REQ,EOT,STX,ETX,ACK,NAK,from host>

Default:

No assignment

Options:

Any ASCII character except a null. Control characters can be used to define RES through NAK in serial commands.

From Host

Definition:

This option allows the handshaking protocol to be initiated from the host, if not configured in an unpolled mode. Messages sent to the host will include the reader’s defined protocol. The status of From Host determines if messages sent from the host to the reader must include the defined protocol. If From Host is disabled, the defined protocol is not included. If From Host is enabled, the defined protocol must be included.

Serial Cmd:

<K140,6,RES,address,REQ,EOT,STX,ETX,ACK,NAK,from host>

Default:

Disabled

Options:

0 = Disabled

2-8

1 = Enabled

Quadrus EZ Reader User’s Manual

Page 35

Communications

Multidrop Usage:

A concentrator can be used to connect up to 50 devices to a single host port connection.

Definition:

Multidrop allows up to 50 devices to be connected to a single RS-485 host, with the reader assigned an unique address (from 01 to 50).

Multidrop Addresses:

Each address has its own separate poll and select address (from 1C to 7F hex).

Options:

01 through 50

Serial Cmd:

If selecting Multidrop (K140,5) an address must be defined and appended to the command string. Format: <K140,5,address>

When Multidrop is selected, the protocol characters for RES, REQ, etc. are assigned automatically.

User Defined Multidrop Usage:

This option is used when connecting to a concentrator or other device that does not match standard multidrop protocol. If selecting User Defined Multidrop (7), complete the format by either choosing new parameters or place commas where unchanged data fields occur.

Definition:

User Defined Multidrop allows the user to customize the polling protocol.

Serial Cmd:

<K140,7,RES,address,REQ,EOT,STX,ETX,ACK,NAK> For User Defined Multidrop, first select Multidrop <K140,5>, then User Defined Multidrop <K140,7...>.

Address:

Any single character (02 hex to 7E hex) in the ASCII table can be assigned as the address character. The character chosen is used as the poll character and the subsequent ASCII character becomes the select character. For example, if a ^B (02 hex) is selected as the address, ^C (03 hex) becomes the select address that the host will use in sending host select commands.

Note: Any ASCII character except a null (00) and a ^A (01) can be assigned as an address. Control characters can be used to define RES through NAK in serial commands. Note: Definitions of commands in User Defined and User Defined Multidrop must be duplicated in host applications to enable poll and select sequences to execute correctly during transmission. Note: Typically, parameters in User Defined Multidrop are defined by first enabling Multidrop, then enabling User Defined Multidrop. This pre-loads multidrop characters into the parameters. Then changes are made to individual characters to match the host or other requirements.

Quadrus EZ Reader User’s Manual

2-9

Page 36

RS-232/422 Host Port

Host 422 Status Usage:

RS-232 is an industry standard. RS-422 is used where greater cable lengths are required and/or where noise interference is an issue.

Definition:

Host 422 if enabled allows communication through the 422 I/O lines. When Host 422 is enabled, RS-232 is disabled. When Host 422 is disabled, RS-232 is enabled.

Serial Cmd:

<K102,host 422>

Default:

Disabled

Options:

0 = Disabled

2-10

1 = Enabled

Quadrus EZ Reader User’s Manual

Page 37

Communications

RS-232 Auxiliary Port The auxiliary port offers an alternative port that can be configured to communication in RS-232 in several modes including daisy chain.

Aux Port Connections As with the host port parameters, the auxiliary port settings (baud rate, parity, stop bits, and data bits) must be identical with those of the auxiliary device. Note: Aux port connections are not available when Ethernet is enabled. Usage:

An auxiliary port connects the reader to a remote display or to other readers that can display or transfer data.

Definition:

These commands set the communication parameters with the auxiliary port which can be used to configure menus, send data to the host, display data transmissions originating from the host of the reader, and relay data from other readers set in tandem (daisy chained).

Baud Rate, Aux Port Usage:

Can be used to transfer data faster or match an auxiliary device.

Definition:

The rate at which the reader and host transfer data back and forth.

Serial Cmd:

<K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain ID status,daisy chain ID>

Default:

115.2K

Options:

0 = 600 3 = 4800 6 = 38.4K

1 = 1200 4 = 9600 7 = 57.6K

2 = 2400 5 = 19.2K 8 = 115.2K

Parity, Aux Port Usage:

Only changed if necessary to match host setting.

Definition:

An error detection routine in which one data bit in each character is set to 1 or 0 so that the total number of 1 bits in the data field is even or odd.

Serial Cmd:

<K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain ID status,daisy chain ID>

Default:

None

Options:

0 = None

Quadrus EZ Reader User’s Manual

1 = Even

2 = Odd

2-11

Page 38

RS-232 Auxiliary Port

Stop Bits, Aux Port Usage:

Only changed if necessary to match host setting.

Definition:

Allows the user to select the last one or two bits in each character to indicate the end of the character.

Serial Cmd:

<K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain ID status,daisy chain ID>

Default:

One

Options:

0 = One

1 = Two

Data Bits, Aux Port Usage:

Only changed if necessary to match host setting.

Definition:

Number of bits in each character.

Serial Cmd:

<K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain ID status,daisy chain ID>

Default:

Eight

Options:

0 = Seven

1 = Eight

Auxiliary Port Mode Definition:

Determines the flow of data between the auxiliary port device(s), the reader, and the host.

Serial Cmd:

<K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain ID status,daisy chain ID>

Default:

Disabled

0 = Disabled 1 = Transparent 2 = Half duplex 3 = Full duplex 4 = Daisy chain 5 = Command Processing Note: RS-232 host and aux port are available with full functionality. Options:

2-12

Quadrus EZ Reader User’s Manual

Page 39

Communications

Transparent Mode Usage:

A common application, in conjunction with handheld readers, is one that employs an auxiliary readout to detect mis-applied symbols. In Transparent mode data is passed between the auxiliary port and the host. The reader buffers data from the auxiliary port and echoes the keyed data on the auxiliary port. • Auxiliary port data is passed through to the host Aux whenever a return key is pressed at the auxiliary Host Port port or whenever symbol data is sent. If sent with symbol data, it is processed on a first-in/first-out basis. Reader • Auxiliary port data to the host is always sent with a preamble and a postamble. • If the reader is in a polled mode to the host, auxiliary port data will still pass through. • <D> is the only command accepted by the reader from the auxiliary port. All other commands will pass through to the host.

Definition:

Data initiated from the Reader • Transmission to the auxiliary port occurs immediately upon a good read. • Data sent to the auxiliary port does not include a preamble or a postamble. • Communications with the auxiliary port is always in Point-to-Point protocol, even if the host is in a polled protocol mode. Data initiated from the Host • All host data is echoed to the auxiliary port in unpolled mode.

Aux Port

Host

Reader

Aux Port

Host

Reader

Serial Cmd:

<K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain ID status,daisy chain ID> 1 = Transparent

Quadrus EZ Reader User’s Manual

2-13

Page 40

RS-232 Auxiliary Port

Half Duplex Mode Usage:

Useful when the user wants symbol data displayed on an auxiliary menu close to the reader. In Half Duplex mode all auxiliary port data and symbol data is sent directly to the host. Symbol data is displayed on the auxiliary port menu at the same time the data is sent to the host. Data initiated from the Auxiliary Port • Auxiliary port data to the host is ignored if the Aux reader is in a polled mode. Host Port • Auxiliary port data or read data is sent to the host whenever it is received. • Auxiliary port data is not echoed. Reader • Auxiliary port data to the host is always sent without a preamble or a postamble. • <D> is the only command that is accepted by the reader from the auxiliary port. All other commands are passed through to the host.

Definition:

Data initiated from the Reader • Data is transmitted to the auxiliary port at the same time it is transmitted to the host. • Data transmission conforms with all parameters specified in the configuration menu (e.g., Preamble, Postamble, End of Read Cycle).

Aux Port

Host

Reader

Data is initiated from the Host • All host data is echoed to the auxiliary port in unpolled mode.

Aux Port

Host

Reader

Serial Cmd:

2-14

<K101,aux port mode,baud rate,parity,stop bits,data bits> 2 = Half Duplex

Quadrus EZ Reader User’s Manual