Page 261
Utilities
Enter Master Symbol Data Definition:
Allows you to enter master symbol data for a any enabled master symbol index number (1 to 10), provided the total number of characters does not exceed the specified maximum.
Serial Cmd:
<K231,master symbol number,master symbol data>
Options
Enter data for 1 to 10 symbols (any combination of ASCII text up to the specified maximum. For example, to enter data for master symbol 9, after making certain that master symbol database size is enabled for 9 or more symbols, send <K231,9,data>. Caution: If no data is entered, the existing data will be deleted. 1. Open the Utilities menu. 2. Set the number of master symbols you want to create in Master Symbol Database Size. 3. Double-click on each symbol number you want to setup and copy or type in your data in the popup dialog and click OK.
ESP:
4. When all your data has been enter, click on the button, Send Database to the Reader.
Quadrus EZ Reader User’s Manual
12-9
Page 262
Master Database
Request Master Symbol Data Definition:
Serial Cmd:
Returns master symbol data for any enabled master symbols from 1 to 10. For example, to request master symbol #5, enter <K231?,5>. The reader transmits master symbol #5 data in brackets in the following format: <5/ data>. If no master symbol data is available, the output will be: <5/>. <K231?,master symbol number> Caution: Be sure to add the ? or you will delete the master symbol. Returns the number of master symbols if no number is included.
ESP:
1. Click the Utilities button and the Master Database tab. 2. Click on the Receive Reader’s Database button.
Request All Master Symbol Data Serial Cmd:
<K231?> This command will return master symbol data for all symbols enabled (up to 10).
Read Next Symbol as Master Symbol Definition:
After you’ve set the size in the database, you can order the reader to read the next symbol as the master symbol for any given master symbol number.
Serial Cmd:
<G master symbol number> To store the next symbol read as master symbol #1, send: <G> or <G1>. To store next symbol read as the master symbol for any other master symbol database number, send: <Gmaster symbol number [1-10]>. For example, <G5> will cause the next symbol read to be entered as master symbol #5.
ESP:
In the Master Database tab, under the Output Format menu 1. Select the master symbol index number in which you want to store the symbol data. 2. Click on Read Symbol into Selected Index. Caution: If you’ve selected an index which has existing data, that data will be copied over by scanned data when you use this command.
12-10
Quadrus EZ Reader User’s Manual
Page 263
Utilities
Request New Master Status Usage:
Informs the user when a new master symbol is pending and which position it is in.
Definition:
Returns the position in the master symbol database that will be loaded on the next read.
Serial Cmd:
<NEWM> The reader returns: <NEWM/next master to load> Once a symbol has been read and loaded, the status will be cleared and a response will be <NEWM/0>.
Delete Master Symbol Data Definition:
You can directly delete the master symbol data by serial command or ESP. 1. Click the Utilities button to access the master symbol: 2. Click the Master Database tab and double-click the symbol number you want to delete. 3. Delete text and Click OK.
ESP:
Serial Cmd:
<K231,master symbol number,> To delete a master symbol, enter the database number and a comma, but leave the data field empty. For example, to delete master symbol #5, send the following <K231,5,>. The command is entered with a blank master symbol data field which tells the reader to delete the selected master symbol from the database.
Quadrus EZ Reader User’s Manual
12-11
Page 264
Firmware
Firmware By ESP
Firmware Update Application code versions are specific to your reader. Consult with your sales representative before downloading application code. If needed, an application code will be sent to you in the form of a *.mot file. To download application code: 1. First make sure the host is connected to your reader. 2. Apply power to the reader. 3. Before updating, you should verify the current firmware. 4. Click in the Firmware Update text box and select the file type you want to download. This will open a file locator box. 5. Navigate to the appropriate file (a *.mot file) and open the file. Caution: Do not interrupt power or disconnect the host cable while download is in progress. Be sure that each download is complete before moving on to the next. Important: When updating firmware, be sure that the application code, boot code, DSP code, and FPGA code are versions that are compatible with each other.
12-12
Quadrus EZ Reader User’s Manual
Page 265
Utilities
Firmware Verification Request Part Number You can send a request to the reader for part numbers, checksums, boot code, and application code.
By ESP You can access Part Numbers from the Utilities menu. 1. Click the Firmware tab. 2. From the pull-down selection box to the left of the Request Part No., make your selection. 3. Select the code type to see part number displayed in the box to the right.
By Serial Command Upon sending <#> the reader returns: <#b/BOOT_CODE><#a/APP_CODE><#d/DSP_CODE><#f/FPGA_CODE>. Upon sending <#a> the reader returns: <#a/APP_CODE>. Upon sending <#b> the reader returns: <#b/BOOT_CODE>. Upon sending <#d> the reader returns: <#d/DSP_CODE> Upon sending <#f> the reader returns: <#f/FPGA_CODE>
Quadrus EZ Reader User’s Manual
12-13
Page 266
Firmware
Request Checksum You can send a request to the reader for part numbers, checksums, boot code, and application and code. Checksums verify a reader’s flash memory.
By ESP You can access Checksum from the Utilities menu. 1. Click the Firmware tab. 2. From the pull-down selection box to the left of the Request Checksum, make your selection. 3. Select the code type to see the checksum displayed in the box to the right.
By Serial Command Upon sending <!> the reader returns four 4-digit hex numbers that are displayed under Check Sum and apply to APP_CODE, BOOT_CODE, DSP_CODE, and FPGA_CODE. Upon sending <!a> the reader returns a 4-digit hex number that is displayed under Application Code. Upon sending <!b> the reader returns a 4-digit hex number that is displayed under Boot Code. Upon sending <!d> the reader returns a 4-digit hex number that is displayed under DSP Code. Upon sending <!f> the reader returns a 4-digit hex number that is displayed under FPGA Code.
12-14
Quadrus EZ Reader User’s Manual
Page 267
Utilities
Sensor Type Request Sensor Type Definition:
Reports the type of image sensor installed in the reader. This is a read-only command. To obtain the image sensor status, send the command as a status request.
By ESP
By Serial Command Serial Cmd:
<op,10>
When you send this command, the Quadrus EZ responds with a long string of status values related to the reader. Within this string you will see either: SENSOR=CCD or SENSOR=CMOS
Quadrus EZ Reader User’s Manual
12-15
Page 268
Bar Code Configuration
Bar Code Configuration Definition:
Bar code configuration is a way of programming the reader by using Data Matrix ECC200 symbols.
Serial Cmd:
<BCCFG>
Bar code configuration can be entered three different ways: 1. By forcing the reader into bar code configuration mode by serial command <BCCFG>. 2. By configuring one of the 4 EZ button positions to bar code configuration mode. 3. By reading a Data Matrix symbol with a special code word used by ISO/IEC 16022 to signify reader programming. This can be either in a regular read cycle or in read rate. Reading this symbol in the calibration routine will have no effect.1 Once Bar Code Configuration mode has been entered, the Data Matrix symbols can be thought of as serial data. You can configure the reader by printing labels in Microscan’s serial command format. Commands are processed as if the data were streamed in through the serial port. The reader will acknowledge the symbol with a beep, green flash, and echo the serial data to the host. If the command causes the reader to produce more serial output such as serial verification or counter requests, the data will be routed to the host port. The Bar code configuration mode can be exited by any reset <A> or <Z> command as well as a <J> or a quick press and release of the EZ button. The command to exit bar code configuration can be included as part of the bar code, for example, encoding <K200,4><K220,1><J> into a Data Matrix symbol. This would configure the reader to serial trigger mode, program a new trigger to end the read cycle, and exit the bar code configuration mode with the <J>. To end all EZ button functions, press the EZ button and quickly release.
1. In normal reading modes, it is required to read a special Data Matrix symbol with a special codeword used by ISO/IEC 16022 to signify reader programming.
12-16
Quadrus EZ Reader User’s Manual
Page 269
Utilities
Defaulting/Saving/Resetting Understanding and controlling your reader’s active, saved, and default settings is critical to the operation of your reader. Software Reset/Save/Recall Commands Function
Saved for Power-on
Resets (not saved for power-on)
Reset Reset and recall Microscan defaults Reset and recall power-on parameters Reset and recall customer default parameters Save current settings for poweron
Serial Cmd <A>
ESP (first, right click in any menu tree)a Save to Reader, Send No Save
EZ Button No
<Ard>
No
No
<Arp>
No
No
<Arc>
No
No
<Z>
Save to Reader, Send and Save Save to Reader, Send and Save Customer Defaultsb
No
Save current settings as customer default parameters
<Zc>
Recall Microscan default parameters and save for power-on
<Zrd>
No
No
Recall customer default parameters and save for power-on
<Zrc>
No
Press and hold while powering on reader
No a. When you right click in a menu tree and select Default Current Menu Settings or Default All ESP Settings, it is important to note that only ESP settings are defaulted. To save these defaults to the reader itself, you need to follow up with a <Z> or Save to Reader, Send and Save command. b. Only available in ESP if enabled under the Options pulldown menu.
Resets Resets (“A” commands) affect only the current settings (active memory) and are not saved for power-on.
Saved for Power-on Power-on parameters (“Z” commands) are saved to NOVRAM and recalled and loaded into current parameters when power is cycled or the <Arp> command is issued.
Defaults Defaults are Microscan firmware settings or saved customer settings that can be recalled, either by software or hardware reset.
Quadrus EZ Reader User’s Manual
12-17
Page 270
Defaulting/Saving/Resetting
Customer Default Parameters Customer default parameters (saved by <Zc>) are the same set of parameters as poweron parameters but are saved in a different, isolated section of NOVRAM. This allows a user to essentially create a backup set of parameters that can be recalled in the event that the current parameters or power-on parameters have been accidentally changed or no longer desired. It is important to note that a hardware default does not affect customer default parameters. For example, a user that has inadvertently changed communication settings and saved them with a <Z> command, may not know the correct settings or doesn't have the capability to communicate at those settings. By first doing an EZ button or hardware default to restore the known Microscan defaults, the user can then recall the previously customer saved settings with an <Arc> or <Zrc> command.
Microscan Default Parameters Microscan default parameters are contained in the firmware and cannot be changed.
Software Defaults Microscan default parameters can be recalled (loaded into current settings) with <Ard> command or recalled and saved for power-on with the <Zrd> command.
Hardware Default If a software default reset is not possible, it may be necessary to reset the reader by shorting (connecting) specific pins. This procedure has the same effect as the <Zrd> software command. Important: For this reset to occur, this command must be executed within 60 seconds after a power-on or a reset. 1. Apply power to the reader. 2. If using an IB-150, locate pins 7 and 11 on the host connector. Caution: Be certain that the correct pins are located. Connecting the wrong pins could cause serious damage to the unit. 3. Momentarily connect these wires (or pins) and listen for a series of short beeps. 4. Within 3 seconds, connect them again. A longer beep should be heard. If not, repeat the process.
Default on Power-On You can also use the EZ button to default the reader by holding down the EZ button while applying power to the reader, provided that this feature is enabled.
12-18