The text of a manual · part 28 of 37
Quadrus EZ Reader User's Manual, pages 271 to 280
Pages 271 to 280 of 366
The original document is the PDF (2.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Microscan EZ 6700 EX
Page 271
Utilities
Reader Status Requests <?> Reader Status Byte The reader responds to a status request <?> with a two character hex value, for example <?/22>. To determine the status: 1. Look up the binary conversion in the hex-to-binary table. For example, the first 2 in binary would be 0 0 1 0 as read from binary digits 3 through 0; the second 2 the binary digits 7 through 4 which is also 0 0 1 0. 2. Next, enter your binary values in the “Reader Status” table in the “Binary” column next to the appropriate bit. Quadrus EZ Status Bit 0 1 2 3 4 5 6 7
Binary 0 1 0 0 0 1 0 0
Reader Status Command error detected Command received Communication error detected Flash sector unprotect failure Host/Aux port buffer overflow Reader is in a read cycle Software Watch dog reset Hardware Watch dog reset
3. Under “Binary,” interpret 1s as true and the 0s as not true. For example, bit 1 has a 1 in the “Binary” column, indicating “Command Received.” Bit 5 is also a 1 indicating that the “Reader is in a read cycle.”
<?1 > Extended Status The reader responds to an extended status request <?1> with several fields. These represent, in order: the status byte as discussed above, the boot part number, application part number, FPGA part number, Flash checksum, and Flash parameter checksum.
Hex Value to Binary Conversion Hex Value 0 1 2 3 4 5 6 7 8 9 A B C D E F
Binary Bit Digits 7
6
5
3
2
1
4 0
0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1
0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1
0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1
0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1
<K?> Configuration Command Status Returns the current status of all configuration commands.
Quadrus EZ Reader User’s Manual
12-19
Page 272
Other Operational Serial Commands
Other Operational Serial Commands The following serial utility commands can be entered from the ESP Terminal window or a PLC:
Y-Modem Upload Image <uy,filename>
Calibration <op,6,1> Calibrate to optimize Contrast and Readability <op,6,0> End Calibration <op,7> Determine Calibration Progress <@DPM> Calibrate to optimize DPM (Direct Part Marking) features
Image Library Request Manages files and directories in a selected directory. <op,9,source> File Source (Nothing) /
/saved *.* /del /saved/del del*.*
Explanation All files in “root” directory All files in “root” directory All files in “saved” directory All files in all directories Deletes all files in the root director Deletes all files in the saved directory Deletes files in all directories
Autodiscrimination You can enable most or specific symbol types by the following operational commands. Default:
Code 39 (only)
Options:
<P> Enables most symbol types. <Q> Enable Code 39 only <R> Enable Codabar only <S> Enable I 2/5 only
12-20
Quadrus EZ Reader User’s Manual
Page 273
13 Unique Item Identifiers Contents UII Overview................................................................................................................................13-2 Non-UII Characters in a UII Message Stream.............................................................................13-3 UII Mode Features.......................................................................................................................13-4 Error Messaging ..........................................................................................................................13-6 Valid Formats ..............................................................................................................................13-8
This section explains the structure and purpose of Unique Item Identifiers (UIIs), and how to configure the Quadrus EZ to read them.
Quadrus EZ Reader User’s Manual
13-1
Page 274
Overview of IUID and UII
Overview of IUID and UII The Department of Defense (DoD) now requires “Item Unique Identification” (IUID) for all products sold to the DoD by private vendors. A Unique Item Identifier (UII) is like a Social Security number for each part. The UII must be encoded in a Data Matrix ECC 200 symbol that conforms to the data structure defined in the DoD’s “Guide for Uniquely Identifying Items”.
UII Elements UIIs come in two forms, called Construct 1 and Construct 2. The following is an example of Construct 2. Construct 1 is identical, except that it doesn’t include a part number. Construct 2 is composed of three basic elements: (Issuing Agency Code) (2.) Part Number (1.) Enterprise Identifier (EID): A number assigned and controlled by a specific agency (e.g. Dunn and Bradstreet or GS1 US).
UN ABCD 98 / 76 123-AC
(3.) Serial Number
Encoding a UII The information in a Data Matrix UII also includes a compliance indicator, data qualifiers, and data element separators. None of these elements are part of the final UII. When UII-Only is enabled in the Quadrus EZ, the characters that are not part of the UII are removed from the decoded symbol data. Only characters that make up the UII are passed on to the host computer. Otherwise, the symbol is rejected. Compliance Indicator
Format Header
Enterprise Identifier
Part Number
Serial Number
Message Trailer
[)> {RS} DD {GS} DUNABCD {GS} PN098 / 76 {GS} SEQ123-AC {RS} {EOT}
Trailer Character
13-2
Data Element Separator
Data Element Separator
Data Element Separator
Trailer Character
Quadrus EZ Reader User’s Manual
Page 275
Unique Item Identifiers
Non-UII Characters in a UII Message Stream The table below identifies and describes all characters in a UII message stream that are not part of the final UII sent to the host. Non-UII Characters in a UII Message Stream Compliance Indicator
Identifies to the Quadrus EZ that the symbol contains a UII.
Format Header
Describes the type of data qualifier used. These qualifiers include AI (format 05), DI (format 06), and TEI (format DD).
Trailer Character
Data Element Separator Message Trailer Data Qualifier
An ASCII character that separates the compliance indicator from the format header information, and also appears at the end of the message stream. An ASCII character used to separate data fields. Identifies the end of the message within the data stream. Defines each data element placed in the UII message stream.
When a message stream in any of the three available formats is read by the Quadrus EZ, non-UII characters are omitted and the UII is sent to the host. AI (format 05)
DI (format 06)
(form
TEI (format DD)
Reader
UII
Host
Quadrus EZ Reader User’s Manual
13-3
Page 276
UII Mode Features
UII Mode Features UII-Only Enabled
Allows the Quadrus EZ to read only UII message streams encoded in ECC 200 Data Matrix symbols and to send the UII output to the host computer. The Quadrus EZ will not read any other symbol data when UII-Only is enabled.
UII-Only Enabled with Error Messaging
Allows the Quadrus EZ to read only UII message streams encoded in ECC 200 Data Matrix symbols and to send the UII output to the host computer. In addition, the Quadrus EZ will send an error message to the host if the UII message stream is invalid.
UII Enabled with Pass Through
Allows both UII-encoded symbols and non-UII symbols to be decoded and sent to the host.
UII Enabled with Error Messaging and Pass Through
Allows the Quadrus EZ to decode UII symbols and non-UII symbols, and to provide error messages if the UII message stream is invalid.
UII Mode by ESP
Click this button to bring up the I/O Parameters menu.
To change settings, double-click the setting and use your cursor to scroll through the options.
Open the nested Unique Item Identifier option in the I/O Parameters tree control. Note: The setting Enabled in ESP’s UII tree controls is functionally identical to UII Enabled with Pass Through in the table at the top of this page. Therefore, the combination of UII Enabled and Error Message Enabled is functionally identical to the UII Enabled with Error Messaging and Pass Through condition in the table at the top of the page.
13-4
Quadrus EZ Reader User’s Manual
Page 277
Unique Item Identifiers
UII Mode by Serial Command Serial Cmd:
<K455,status,errstatus>
Default:
Disabled
Options:
0 = Disabled 1 = UII Enabled with Pass Through 2 = UII-Only Enabled
UII Disabled No UII is constructed when symbol data is read.
UII Enabled with Pass Through Usage:
Use when symbols may contain either non-UII data or UII data.
Definition:
Message streams with valid UII compliance indicators will be evaluated as UIIs. All other data will be processed in the normal manner.
UII-Only Enabled Usage:
Use when symbols will contain only UII data, or when symbols with non-UII data are to be rejected.
Definition:
All data will be treated as potential UII data and symbols that do not comply with DoD UII guidelines will be rejected.
UII Mode Error Messaging Serial Cmd:
<K455,status,errstatus>
Default:
Disabled
Options:
0 = Disabled 1 = Enabled
Usage:
Identifies problems with data in UII format.
Definition:
Evaluates the UII elements and returns an error message if invalid UII elements are found.
Important: When Error Messaging is disabled, any symbol with data that does not conform to UII format will be treated as a NOREAD.
Quadrus EZ Reader User’s Manual
13-5
Page 278
Error Messaging
Error Messaging This feature is used to determine if UII message streams are in the correct format. When Error Messaging is enabled, the Quadrus EZ sends a message to the host indicating an error every time a bad symbol is read. The table below shows examples of error messages. Examples of Error Messages
Invalid Format [)>{RS}15{GS}800406141411A0B9C3D6{RS}{EOT} Header Error message: “Invalid UII Format Header”
(01 + 21)
Invalid AI [)>{RS}05{GS}0100061414199999{GS}311A0B9C3D6{RS}{EOT} Error message: “Invalid AI”
(UN + 12V + 1P + S)
Invalid DI [)>{RS}06{GS}12X077991289{GS}1P4202435{GS}S10936{RS}{EOT} Error message: “Invalid DI”
Invalid TEI
Space in Data Qualifier
(D + CAG + SER) [)>{RS}DD{GS}CAX987654{GS}SERMKLJHUIYD{RS}{EOT} Error message: “Invalid TEI”
[)>{RS}05{GS}8 0040614 1411 A0 B9 C3D6{RS}{EOT} Error message: “Invalid AI (or DI or TEI depending on format in use)”
Lower Case [)>{RS}05{GS}800406141411a0B9C3d6{RS}{EOT} Characters Error message: “Invalid Characters in Data”
13-6
Quadrus EZ Reader User’s Manual
Page 279
Unique Item Identifiers Examples of Error Messages (cont.)
Invalid Characters
UII Too Long
[)>{RS}05{GS}800406141411#0B9C3D6{RS}{EOT} Error message: “Invalid Characters in Data”
(Character limit:78) [)>{RS}05{GS}80021234567891123456789212345678931234567 894123456789512345678961234567897123456789{RS}{EOT} Error message: “UII Too Long” (Character limit: 32)
Part Number Too [)>{RS}DD{GS}DUNABCD{GS}PNO1234567891123456789212 Long 345678931234{GS}SEQ123-AC{RS}{EOT} Error message: “UII Part Number Too Long”
(Character limit: 30)
Serial Number Too [)>{RS}DD{GS}DUNLong ABCD{GS}PNO09876{GS}SEQ123456789112345678921234567 8931{RS}{EOT} Error message: “UII Serial Number Too Long”
EID Too Long
Invalid Compliance Indicator
(Character limit: 13) [)>{RS}DD{GS}DUN12345678911234211{GS}PNO98/76{GS} SEQ123-AC{RS}{EOT} Error message: “UII EID Too Long”
[))>{RS}05{GS}800406141411A0B9C3D6{RS}{EOT} Error message: “Invalid UII Compliance Indicator” The following symbol will read in UII with Pass Through mode, because the invalid compliance indicator suggests that the encoded characters form a non-UII message stream.
Quadrus EZ Reader User’s Manual
13-7
Page 280
Valid Formats
Valid Formats The table below shows examples of correctly encoded UII message streams and the decoded UII output. Examples of Valid UII Message Streams and UII Output
AI (Format 05)
Encoded message stream: [)>{RS}05{GS}0100061414199999{GS}211A0B9C3D6{RS}{EOT} Decoded UII output: 000614141999991A0B9C3D6
DI (Format 06)
Encoded message stream: [)>{RS}06{GS}18SOCVA5674A36458{RS}{EOT} Decoded UII output: DOCVA5674A36458
TEI (Format DD)
13-8
Encoded message stream: [)>{RS}DD{GS}CAG987654{GS}SERMKJHUIYD{RS}{EOT} Decoded UII output: D987654MKLJHUIYD
Quadrus EZ Reader User’s Manual