Page 251

Terminal

Terminal Window Menus Right click on the Terminal window to display the following dropdown menu: • Copy selected text to clipboard. • Paste from Terminal or computer text. • Clear all text in Terminal window. • Select All text in the Terminal window. • Save... brings up a save as dialog box. • Change Font... of data text, brings up a text dialog. • Change Echo Font... to change typed in text or commands. • Change Background Color of Terminal window. • Default Settings changes all the above back to default settings.

Terminal Dropdown Menu The dropdown Terminal menu has Capture Text and Save Current Text functions, as well as the functions defined above. • Capture lets you append data in real time to a text file of your choice. While in operation, the text file cannot be opened. You can select Pause to interrupt the capture flow or Stop to end the flow and open the file. • Save Current Text... saves all text in the Terminal window to a text file of your choice.

Quadrus EZ Reader User’s Manual

11-5

Page 252

Terminal Window Menus

11-6

Quadrus EZ Reader User’s Manual

Page 253

12 Utilities Contents Utilities Serial Commands .......................................................................................................... 12-2 Read Rate .................................................................................................................................. 12-3 Counters ..................................................................................................................................... 12-4 Device Control ............................................................................................................................ 12-6 Master Database ........................................................................................................................ 12-7 Firmware................................................................................................................................... 12-12 Bar Code Configuration. ........................................................................................................... 12-16 Defaulting/Saving/Resetting ..................................................................................................... 12-17 Reader Status Requests .......................................................................................................... 12-19 Other Operational Serial Commands ....................................................................................... 12-20

Utility commands are generally commands that are performed during reader operations to check read rates, determine read rates or perform miscellaneous operations on reader hardware. Serial utility commands are not prefaced with a “K” and a numeric code. Nor do they require an initialization command (<A> and <Z>). They can be entered from within any terminal program or from within ESP in the Terminal window or the window adjacent to the Utilities menu. Note: The characters NULL <> and , can only be entered through embedded menus, not through ESP or serial commands.

Quadrus EZ Reader User’s Manual

12-1

Page 254

Utilities Serial Commands

Utilities Serial Commands Read Rate

Counter Request and Clear

Master Database

Part Number Checksum/

Device Control

Default/Reset/Save

Reader Status Commands

12-2

<C> <Cp> <J> <N> <O> <T> <U> <V> <W> <X> <Y> <E> <F> <G> <M?> <K231,master symbol number,master symbol data> <#> <#a> <#b> <#d> <#f> <!> <!a> <!b> <!d> <!f> <L1> <L2> <L3> <A> <Ard> <Arp> <Arc> <Z> <Zc> <Zrd> <Zrc> <K?> <-> <?> <?1>

Enter Decode Rate Test Enter Percent Rate Test Exit Decode Rate and Percent Rate Test Noread Counter Noread Counter Reset Trigger Counter Trigger Counter Reset Good Read/Match Counter Good Read/Match Counter Reset Mismatch Counter Mismatch Counter Reset Enable Master Symbol Disable Master Symbol Store next Symbol read to Database. Request Master Symbol Information Request Master Symbol Information for specific database number. Display Software Code Part Numbers Display Application Code Part Number Display Boot Code Part Number Display DSP Part Number Display FPGA Part Number Display all 3 Checksums of Flash memory Display Application Code Checksum Display Boot Code Checksum Display DSP Code Checksum Display FPGA Code Checksum Programmable Output 1 Programmable Output 2 Programmable Output 3 Reset (does not save for power-on) Reset and recall Microscan defaults Reset and recall power-on parameters Reset and recall customer default parameters Save current settings for power-on Save current settings as customer default parameters Recall Microscan default parameters and save for power-on Recall customer default parameters and save for power-on All Configuration Commands Status Input Status Reader Status Extended Reader Status

Quadrus EZ Reader User’s Manual

Page 255

Utilities

Read Rate By ESP You can access Read Rate from the Utilities menu in the Read Rate tab. To see the number of decodes per second, click the Decodes/sec radio button and click the Start button. To see the percentage of decodes, click the Percent radio button and Start button. To end a read rate routine, click the Stop button (same as the Start button).

Read Rate by Serial Command Enter Decodes/Second Test Sending <C> instructs the reader to transmit the decodes per second and symbol data (if any). The decode rate can vary dramatically due to the angle and location of the symbol in relation to the field of view. This test is very useful in aligning and positioning the reader during setup.

Enter Percent Test Sending <Cp> instructs the reader to transmit the percentage of decodes and any read symbol data.

Enable PDF Information Sending <a1> will cause PDF417 data to be prefaced with information consisting of error correction level (ECC Level n), number of rows (n Rows), number of columns (n Columns), number of informative code words (n Info Code Words) and the number of data characters (n Data Bytes). This feature can be disabled by re-sending <a1>.

End Read Rate Test Sending <J> ends both the Percent test and the Decodes/Second test.

Quadrus EZ Reader User’s Manual

12-3

Page 256

Counters

Counters Counter commands can be a numeric value from 00000 to 65,535. After reaching the maximum numeric limit of 65,535, an error message will be displayed and the counter will automatically roll-over and start counting again at 00000. To obtain the cumulative total of counts after the roll-over has occurred, add 65,536 per each roll-over (the reader does not keep track of the number of roll-overs) to the current count. Note: All counter values will be lost if power is recycled to the reader or the reader receives a reset or save command.

By ESP You can access Counters from the Utilities menu. Click the Request button to display the appropriate count or Clear to set counter to zero.

Counters by Serial Command Noread Counter Sending <N> displays the total number of noreads that have occurred since the last reset.

Noread Counter Reset Sending <O> sets Noread Counter to 00000.

Trigger Counter Sending <T> displays the total number of triggers since the last reset.

Trigger Counter Reset Sending <U> sets the trigger counter to 00000.

12-4

Quadrus EZ Reader User’s Manual

Page 257

Utilities

Good Read/Match Counter (or Good Read Counter) Sending <V> displays the total number of good reads matching the master symbol or, if Master Symbol is not enabled, the number of good reads since the last reset. This counter is always enabled, but will only work as a match count when Master Symbol is enabled. If Master Symbol is not enabled, this counter records the number of good reads. This count can be requested at any time.

Good Read/Match Counter Reset Sending <W> sets the Match Counter to 00000.

Mismatch Counter Sending <X> displays the number of decoded symbols since the last reset that do not match the master symbol.

Mismatch Counter Reset Sending <Y> sets the Mismatch Counter to zero.

Quadrus EZ Reader User’s Manual

12-5

Page 258

Device Control

Device Control By ESP

Device Control By Serial Command Output #1 Pulse Sending <L1> pulses activates the link between Output 1(+) and Output 1(–) of the host connector (regardless of Master Symbol or Output 1 status).

Output #2 Pulse Sending <L2> pulses activates the link between Output 2(+) and Output 2(–) of the host connector (regardless of Master Symbol or Output 2 status).

Output #3 Pulse Sending <L3> activates the link between Output 3(+) and Output 3(–) of the host connector (regardless of Master Symbol or Output 3 status).

Disable Reader Sending <I> will turn the reader OFF, end the current read cycle and not allow the reader to enter a read cycle until turned ON. This feature is useful during extended periods of time when no symbols are being scanned or the reader is being configured. Disabling the reader will not affect any downloaded commands to the reader.

Enable Reader Sending <H> will turn the reader ON and allow it to enter read cycles.

12-6

Quadrus EZ Reader User’s Manual

Page 259

Utilities

Master Database Important: Master Database is used only for comparing entire symbols, when Sequential and Wild Card are NOT enabled, and Start Position is equal to 0.

Master Database Overview Usage:

Used where more than one master symbol is required, as in a Multisymbol setup, for matching and other matchcode operations.

Allows you to define up to 10 master symbols as the master symbol database, which can be entered by keyboard, scanned in, displayed, or deleted by serial or ESP commands. 1. Click the Master Database tab.

Definition:

2. Set the Master Symbol Database Size. 3. Select database index you want to enter the master symbol. 4. Do one of the following to enter master symbol data. a) Double-click the index row to type data directly into index b) Click the Read Symbol into Selected Index to enter the next decoded symbol.

Set master symbol database size here.

Double-click row to enter data into popup dialog box.

Loads the next symbol scanned into selected index.

Loads the reader’s saved master symbols into ESP.

Saves the displayed database to the reader.

Master Database

Important: Master Symbol Database is used only for comparing entire symbols, when Sequential and Wild Card are NOT enabled, and Start Position is equal to 0.

Quadrus EZ Reader User’s Manual

12-7

Page 260

Master Database

Master Symbol Database Size Definition:

Number of Master Symbols allows you to select 1 to 10 master symbols for the master symbol database.

Serial Cmd:

<K231,master symbol database size> Note: You must follow this command with a save command <A> or <Z>.

Default:

1

Options:

1 to 10

Use arrows to set Master Symbol Database Size.

Caution: Since the total number of characters available for the master symbol data base is 2710, changes to the Master Symbol Data Base Size will re-allocate the number of characters available for each master symbol and could cause existing master symbols to be deleted (except master symbol #1 unless it also exceeds the size limitation). The table below specifies the maximum number of characters available to each symbol according to the number of master symbols defined, from 1 through 10. Maximum Characters for Master Symbol Master Symbol Number #1 #2 #3 #4 #5

12-8

Maximum Characters 2710 1355 903 677 542

Master Symbol Number #6 #7 #8 #9 #10

Maximum Characters 451 387 338 301 271