The text of a manual · part 20 of 37
Quadrus EZ Reader User's Manual, pages 191 to 200
Pages 191 to 200 of 366
The original document is the PDF (2.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Microscan EZ 6700 EX
Page 191
Matchcode
Sequential Matching Usage:
Useful in tracking product serial numbers that increment or decrement sequentially.
Definition:
With Sequential enabled, Sequential Matching determines if a count is in ascending (incremental) or descending (decremental) order.
Serial Cmd:
<K223,matchcode type,sequential matching,match start position,match length,wild card character,sequence on noread,sequence on mismatch>
Default:
Increment
Options:
0 = Increment
Quadrus EZ Reader User’s Manual
1 = Decrement
7-5
Page 192
Match Start Position
Match Start Position Usage:
Match Start Position is useful in defining specific portions of a symbol for comparisons. For example, if a symbol contains a part number, manufacturing date, and lot code info but the user is only interested in the part number information. With Match Start Position the reader can be set to only sort on the part number and ignore the rest of the characters.
Definition:
Match Start Position determines the portions of symbols that will be matched by defining the first character in the symbol (from left to right) that will be compared with those of the master symbol, when Matchcode Type is set to Enabled or Sequential.
Function:
For example, if Match Start Position is set to 3, the first 2 characters read in the symbol will be ignored and only the 3rd and subsequent characters to the right will be compared, up to the number of characters specified by Match Length.
Serial Cmd:
<K223,matchcode type,sequential matching,match start position,match length,wild card character,sequence on noread,sequence on mismatch>
Default:
0
Options:
0 to 2710
Note: Match Start Position must be set to 1 or greater to enable this feature. A 0 setting will disable this feature.
7-6
Quadrus EZ Reader User’s Manual
Page 193
Matchcode
Match Length Usage:
For example, if Match Length is set to 6 in a 10 character symbol, and Match Start Position is set for 2, only the 2nd through 7th characters (from left to right) will be compared.
Definition:
Defines the length of the character string that will be compared with that of the master symbol when Match Start Position is set to 1 or greater. when Match Start Position is set to 0, no comparison will occur.
Serial Cmd:
<K223,matchcode type,sequential matching,match start position,match length,wild card character,sequence on noread,sequence on mismatch>
Default:
1
Options:
1 to 2710
Quadrus EZ Reader User’s Manual
7-7
Page 194
Wild Card Character
Wild Card Character Usage:
For example, with Wild Card Character defined as the default asterisk, defining CR*34 as the master symbol will result in matches for CR134, CR234, but not CR2345. Entering the wild card at the end of the master symbol as in CR* will result in matches for variable symbol lengths such as CR1, CR23, CR358, etc.
Definition:
Wild Card Character allows a user to define a wild card character as part of the master symbol.
Serial Cmd:
<K223,matchcode type,sequential matching,match start position,match length,wild card character,sequence on noread,sequence on mismatch>
Default:
* (asterisk)
Options:
Any valid ASCII character
7-8
Quadrus EZ Reader User’s Manual
Page 195
Matchcode
Sequence On Noread Usage:
Sequence On Noread is useful when the reader needs to stay in sequence even if no decode occurs.
Definition:
When Sequence On Noread is Enabled and Matchcode is set to Sequential, the reader sequences the master symbol on every match or noread. When disabled, it does not sequence on a noread.
Serial Cmd:
<K223,matchcode type,sequential matching,match start position,match length,wild card character,sequence on noread,sequence on mismatch>
Default:
Enabled
Options:
0 = Disabled
1 = Enabled
As an example of Sequence on Noread Enabled, consider the following series of decodes: Master symbol Decoded symbol Master symbol after decode 001 001 002 002 002 003 003 noread 004 (sequenced on noread) 004 004 005 005 noread 006 (sequenced on noread) 006 noread 007 (sequenced on noread) 007 007 008 As an example of Sequence on Noread Disabled, consider the following series of decodes: Master symbol 001 002 003 003 004 004 004
Decoded symbol 001 002 noread 003 noread noread 004
Quadrus EZ Reader User’s Manual
Master symbol after decode 002 003 003 (not sequenced) 004 004 (not sequenced) 004 (not sequenced) 005
7-9
Page 196
Sequence On Mismatch
Sequence On Mismatch Note: Matchcode must be set to Sequential for this command to function.
Usage:
Enable this parameter if every trigger event should have a decode and more than one consecutive mismatch may occur. Disable this parameter if every trigger event should have a decode but no more than one consecutive mismatch may occur.
Definition:
When set to Enabled, the master symbol sequences on every decode, match or mismatch. When set to Disabled, the master symbol will not sequence whenever consecutive mismatches occur.
Serial Cmd:
<K223,matchcode type,sequential matching,match start position,match length,wild card character,sequence on noread,sequence on mismatch>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
The reader will sequence the master to one more/less than the decoded symbol. As an example of Sequence On Mismatch Enabled, consider the following decodes: Master symbol Decoded symbol Master symbol after decode 001 001 002 002 002 003 003 abc 004 (sequenced on mismatch) 004 004 005 005 def 006 (sequenced on mismatch) 006 ghi 007 (sequenced on mismatch) 007 007 008 As an example of Sequence On Mismatch Disabled, consider the following decodes: Master symbol Decoded symbol 001 001 002 002 003 abc 004 004 005 def
7-10
006 ghi
006
006
Master symbol after decode 002 003 004 (sequenced because of previous match) 005 006 (sequenced because of previous match) 006 (not sequenced because of previous mismatch) 007
Quadrus EZ Reader User’s Manual
Page 197
Matchcode
Sequence Step Usage:
Useful in applications in which it is desirable to count by intervals other than 1.
Definition:
Sequencing in Matchcode operations can occur in steps from 1 to 32,768. Sequencing performs like a mechanical counter by displaying positive integers and a specific number of digits after roll-overs. For example, 000 – 3 = 997 (not –3) and 999 + 3 = 002 (not 1002).
Serial Cmd:
<K228,sequence step>
Default:
1
Options:
1 to 32,768
As an example of Sequence Step, if Sequence Step is set to 3 and Sequential Matching is set to Increment. Master symbol 003 003 003 006 006 006
Quadrus EZ Reader User’s Manual
Decoded symbol 001 002 003 004 005 006
Master symbol after decode 003 003 006 006 006 009
7-11
Page 198
Match Replace
Match Replace Usage:
Provides a convenient shortcut for applications that need to output a predefined text string whenever a symbol matches a master symbol.
Definition:
Outputs a user-defined data string whenever a match occurs and Matchcode is enabled.
Serial Cmd:
<K735,status,replacement string>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Replacement String Definition:
User-defined string that when enabled will replace the matchcode data.
Serial Cmd:
<K735,status,replacement string>
Default:
MATCH
Options:
Any ASCII string up to 128 characters.
7-12
Quadrus EZ Reader User’s Manual
Page 199
Matchcode
Mismatch Replace Usage:
Provides a convenient shortcut for applications that need to output a predefined text string whenever a symbol does not match a master symbol.
Definition:
Outputs a user-defined data string whenever a mismatch occurs and Matchcode is enabled.
Serial Cmd:
<K736,status,replacement string>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Replacement String Definition:
User-defined string that when enabled will be output whenever a mismatch occurs.
Serial Cmd:
<K736,status,replacement string>
Default:
MISMATCH
Options:
Any ASCII string up to 128 characters.
Quadrus EZ Reader User’s Manual
7-13
Page 200
New Master Pin
New Master Pin Usage:
Some applications require the line worker to change the master symbol. This can be done by installing a switch at the location of the reader. It is very common to have a keyed switch so that accidental switching does not occur.
Definition:
After New Master Pin is enabled, a pulse can be received on the new master pin that will cause the reader to record the next decoded symbol(s) as the new master symbol(s). It is important to note that the enabling New Master Pin does not in itself cause a master symbol to be recorded. The master pin must then be activated momentarily (for a minimum of 10 ms) before a master symbol can be read into memory.
Serial Cmd:
<K225,status>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
After New Master Pin has been enabled and the pin activated, decodes will be saved in the master database beginning with master symbol #1. If the reader is configured for a multisymbol read cycle (Number of Symbols is greater than 1), the remaining decodes will be saved in each consecutive master symbol location. For example, if Number of Symbols is set to 3 and New Master Pin is then activated, at the end of the next read cycle, the decoded symbols will be saved as master symbols 1, 2, and 3.
7-14
Quadrus EZ Reader User’s Manual