Page 181

Symbol Quality

Pixels per Element Definition:

The number of pixels for each element, either dark or light for both x and y directions. If enabled, is appended to the symbol.

Serial Cmd:

<K710,percent cell damage,total read time,capture time,locate time,decode time,pixels per element,ecc level,matrix size,quiet zone>

Default:

Disabled

Options:

0 = Disabled

1 = Enabled

ECC Level Definition:

Outputs the ECC type symbology. If enabled, is appended to the symbol.

Serial Cmd:

<K710,percent cell damage,total read time,capture time,locate time,decode time,pixels per element,ecc level,matrix size,quiet zone>

Default:

Disabled

Options:

0 = Disabled

1 = Enabled

Matrix Size Definition:

Defines the symbol matrix size, in number of pixels in both the x and y axis. If enabled, is appended to the symbol.

Serial Cmd:

<K710,percent cell damage,total read time,capture time,locate time,decode time,pixels per element,ecc level,matrix size,quiet zone>

Default:

Disabled

Options:

0 = Disabled

1 = Enabled

Quiet Zone Definition:

If enabled, the size of the quiet zone is evaluated and a PASS or FAIL message is appended to the symbol.

Serial Cmd:

<K710,percent cell damage,total read time,capture time,locate time,decode time,pixels per element,ecc level,matrix size,quiet zone>

Default:

Disabled

Options:

0 = Disabled

Quadrus EZ Reader User’s Manual

1 = Enabled

6-9

Page 182

Data Matrix

Inkjet/Direct Symbol Quality Parameters related to inkjet, dot peen, and laser and chemical etching.

Dot Shape Definition:

The shape of the symbol’s printed or dot peen markings.

Serial Cmd:

<K711,dot shape,marking method>

Default:

Round

Options:

0 = Round

1 = Square

Marking Method Definition:

The marking method used to create the symbol.

Serial Cmd:

<K711,dot shape,marking method>

Default:

Dot Peen

Options:

0 = Dot Peen

1 = Laser or Chemical

Dot Center Offset

Definition:

Measures the deviation from the ideal dot centers. If enabled, a grade is appended to the symbol. The worst case gives the quality of the worst dot in percentage and its position in the grid. Passing grades are 80 to 100%. Grading: A if 0 - 2% B if 3 - 7% C if 8 - 13% D if 14 - 20% F if > 20% Note that if the dot isn't a circle or an ellipse (with its major or minor axes parallel or perpendicular to the L-Pattern), then the calculated offset may be incorrect. So if a dot fails on center offset, it may only indicate that the dot is out-of-shape. Also note the ideal dot centers are based upon the prior gridmapping calculation. It is not assumed that the cells are evenly placed, and they are adjusted if they are skewed.

Serial Cmd:

<K712,dot center offset,cell fill,dot ovality,angle of distortion>

Default:

Disabled

Options:

0 = Disabled 2 = Average

6-10

1 = Worst Case 3 = Both

Quadrus EZ Reader User’s Manual

Page 183

Symbol Quality

Cell Fill

Definition:

Percentage of the ideal cell size that the dot fills. Worst Case indicates the quality of the worst dot in percentage and its position in the grid. For dot peen symbols this is referred to as Cell Size, and for Laser or Chemical this is called Cell Fill. The calculation used for both is similar. If enabled, the grading letter is appended to the symbol. Grading: A if 0 - 2% B if 3 - 7% C if 8 - 13% D if 14 - 20% F if > 20% Dot Peen, Round Laser/Chemical measures dot size from center of the dot, averages the maximum and minimum, and compares it with the ideal cell size to find the percentage. Square Laser/Chemical measures dot size from left-right and up-down, on the angle of the symbol, averages the dimensions, and compares it with the ideal cell size to find the percentage.

Serial Cmd:

<K712,dot center offset,cell fill,dot ovality,angle of distortion>

Default:

Disabled

Options:

0 = Disabled 2 = Average

Quadrus EZ Reader User’s Manual

1 = Worst Case 3 = Both

6-11

Page 184

Data Matrix

Dot Ovality

Definition:

Identifies the extent of the oval distortion of the mark. Does not apply when the dots are specified as squares. If enabled, the grading letter is appended to the symbol. Grading: A if 0 - 2% B if 3 - 7% C if 8 - 13% D if 14 - 20% F if > 20% From the center of the dot, searches left-right and up-down, or diagonally negative and positive, on the angle of the symbol to determine the dimension of the dot. The longest dimension is D, and the shortest is d, with Dot Ovality = (D-d) / (Length of the ideal cell).

Serial Cmd:

<K712,dot center offset,cell fill,dot ovality,angle of distortion>

Default:

Disabled

Options:

0 = Disabled 2 = Average

1 = Worst Case 3 = Both

Angle of Distortion

Definition:

The angular deviation from a 90 degree plane between row and column. If enabled, the grading letter is appended to the symbol. Grading: A if 0 - 3.5 degrees B if 3.6 - 7.0 degrees C if 7.1 - 10.5 degrees D if 10.6 - 14.0 degrees F if > 14.0 degrees

Serial Cmd:

<K712,dot center offset,cell fill,dot ovality,angle of distortion>

Default:

Disabled

Options:

0 = Disabled

6-12

1 = Enabled

Quadrus EZ Reader User’s Manual

Page 185

Symbol Quality

Static Symbol Quality Outputs When in a static capture mode, you can send a serial command immediately following a triggered output to see all of the symbol quality outputs. Note: This command does not function in dynamic captures. In the following screen captures, all the symbol quality parameters are “forced;” that is, they are displayed although not individually enabled. When you enable parameters individually, either through the <K707...> command or through ESP, the symbol quality results will be appended to the end of the symbol data.

Static ISO/IEC 15415/Grading Symbol Quality Output <VAL> If the reader decoded a data matrix symbol in its last read cycle, sending a <VAL> serial command will return a report that includes ISO/IEC 15415 and Grading Symbol Quality parameters and symbol data.

Static Inkjet/Direct Symbol Quality Output <VAL2> If the reader decoded a data matrix symbol in its last read cycle, sending a <VAL2> serial command will return a report that includes Inkjet/Direct symbol quality parameters and symbol data.

Quadrus EZ Reader User’s Manual

6-13

Page 186

Static Symbol Quality Outputs

6-14

Quadrus EZ Reader User’s Manual

Page 187

7 Matchcode Contents Matchcode by ESP ....................................................................................................................... 7-2 Matchcode Serial Commands ...................................................................................................... 7-2 Overview of Matchcode ................................................................................................................ 7-3 Matchcode Type ........................................................................................................................... 7-4 Sequential Matching ..................................................................................................................... 7-5 Match Start Position ..................................................................................................................... 7-6 Match Length................................................................................................................................ 7-7 Wild Card Character ..................................................................................................................... 7-8 Sequence On Noread................................................................................................................... 7-9 Sequence On Mismatch ............................................................................................................. 7-10 Sequence Step .......................................................................................................................... 7-11 Match Replace............................................................................................................................ 7-12 Mismatch Replace ...................................................................................................................... 7-13 New Master Pin .......................................................................................................................... 7-14

This section explains the matchcode output functions and the master symbol database setup. Note: The characters NULL <> and , can only be entered through embedded menus, not through ESP or serial commands.

Quadrus EZ Reader User’s Manual

7-1

Page 188

Matchcode by ESP

Matchcode by ESP

Click this button to bring up the Matchcode menu.

To open nested options, single-click the +.

To change a setting, double-click the setting and use your cursor to scroll through the options.

Matchcode Serial Commands Matchcode Type

<K223,type,sequential matching,match start position, match length,wild card character,sequence on noread,sequence on mismatch> <K228,sequence step> <K735,status,replacement string> <K736,status,replacement string> <K225,status> <K224,number of master symbols> <K231,master symbol number,data>

Sequence Step Match Replace Mismatch Replace New Master Pin Number of Master Symbols Enter Master Symbol Data Read Next Symbol as Master <G master symbol number> Symbol Request Master Symbol Data <K231?,>[for all] or <K231?,master symbol number> Delete Master Symbol Data <K231, master symbol number,>

7-2

Quadrus EZ Reader User’s Manual

Page 189

Matchcode

Overview of Matchcode

Definition:

With Matchcode you can store master symbol data in the reader’s memory, compare this data against the read symbols, and define how symbol data and/or discrete signal output will be directed. A master symbol database can be setup for up to 10 master symbols. Note: Matchcode will function with multiple symbols; however if Matchcode Type is set to Sequential or if Triggering Mode is set to Continuous Read 1 Output, Number of Symbols will default back to 1 (if set to any number greater than 1).

Usage:

Matchcode is used in applications to sort, route, or verify data based on matching the specific symbol in a variety of ways as defined in this section. For example, a manufacturer might sort a product based on dates that are embedded in the symbol.

Steps for Entering and Using Master Symbols 1. Set Triggering Mode to External or Serial. 2. Chose the method of symbol comparison that fits your application. 3. Define the output you want to achieve with your matchcode setup. 4. Select the number of master symbols you want to create. 5. Decide which of 4 ways you want enter your master symbol(s): a) Use ESP to type in master symbol data directly; b) Send a serial command with symbol data in the form of <M 231,master symbol#, data>; c) Send a <G> (Read Next Symbol as Master Symbol) command; d) Enable the New Master Pin command and activate a discrete input to store the next symbol read as master symbol. 6. Enter master symbol data using the method determined in step 4.

Quadrus EZ Reader User’s Manual

7-3

Page 190

Matchcode Type

Matchcode Type Definition:

Allows the user to choose the way that master symbols will be compared with subsequently read symbols. Note: First set Triggering Mode to External or Serial.

ESP:

Serial Cmd:

<K223,matchcode type,sequential matching,match start position, match length,wild card character,sequence on noread,sequence on mismatch>

Default:

Disabled

Options:

0 = Disabled 2 = Sequential

Disabled:

Has no effect on operations.

Enabled:

Instructs the reader to compare symbols or portions of symbols with the master symbol.

Sequential:

Instructs the reader to sequence after each match (numeric only) and compare symbols or portions of symbols for sequential numbers. Note: If Matchcode Type is set to Sequential, Number of Symbols will default back to 1 (if set to any number greater than 1).

Wild Card:

Allows the user to enter user defined wild card characters in the master symbol.

7-4

1 = Enabled 3 = Wild Card

Quadrus EZ Reader User’s Manual