Page 171
I/O Parameters
Symbol Quality to Output 3 (Inkjet/Direct) Note: Output On under Output 3 Parameters must be set to Symbol Quality for this output to function.
Serial Cmd:
<K822,output on dot center offset,dot center offset,output on cell fill,cell fill,output on dot ovality,dot ovality threshold,output on angle of distortion, angle of distortion threshold>
Diagnostic Warning to Output 3 Note: Output On under Output 3 Parameters must be set to Diagnostic Warnings for this output to function.
Serial Cmd:
<K792,over temp,service unit,external camera disconnect>
Quadrus EZ Reader User’s Manual
5-55
Page 172
Output 3 Parameters
5-56
Quadrus EZ Reader User’s Manual
Page 173
6 Symbol Quality Contents Symbol Quality by ESP ................................................................................................................ 6-2 Symbol Quality Serial Commands................................................................................................ 6-2 Overview of Symbol Quality ......................................................................................................... 6-3 Global ........................................................................................................................................... 6-4 Data Matrix ................................................................................................................................... 6-5 Static Symbol Quality Outputs.................................................................................................... 6-13
This section describes parameters that, when enabled, will output grades or values that evaluate symbol quality. Note: The characters NULL <> and , can only be entered through embedded menus, not through ESP or serial commands.
Quadrus EZ Reader User’s Manual
6-1
Page 174
Symbol Quality by ESP
Symbol Quality by ESP
Click this Button to bring up the Symbol Quality menu.
To open nested options, single-click the +.
To change a setting, double-click the setting and use your cursor to scroll through the options.
Symbol Quality Serial Commands Total Read Time (global) Symbol Quality Separator/ Data Matrix Output Mode ISO/IEC 15415 Symbol Quality
<K710,[not changed in this context],total read time> <K708,symbol quality separator,data matrix output mode>
<K709,symbol contrast,print growth,axial non-uniformity, unused ecc> <K710,percent cell damage,[see Total Read Time above], Grading Symbol Quality capture time,locate time,decode time,pixels per element,ecc level,matrix size,quiet zone> Inkjet/Direct Symbol Qual- <K711,dot shape,marking method> ity <K712,dot center offset,cell fill,dot ovality,angle of distortion> Static ISO/IEC 15415/ <VAL> Grading Output Static Inkjet/Direct Output <VAL2>
6-2
Quadrus EZ Reader User’s Manual
Page 175
Symbol Quality
Overview of Symbol Quality Information about symbol quality and timing can be appended to symbol data output by enabling specific parameters in ESP or by serial command. The order that these values will be appended corresponds directly to the order in which they appear in this section and in the ESP Symbol Quality menu. Symbol Quality parameters are separated into ISO/IEC 15415, Grading, and Inkjet/Direct parameters. In addition, there are two parameters, Total Read Time and Symbol Quality Separator, that are common to all.
Reports You can receive comprehensive reports by sending a <VAL> command to obtain an ISO/ IEC 15415/Grading Symbol Quality Report or a <VAL2> for Inkjet/Direct Marking report.
Discrete Outputs Symbol Quality parameters can also be programmed to toggle discrete outputs in response to symbol quality changes (see "Symbol Quality to Output 1 (ISO/IEC 15415)" on page 5-46).
Quadrus EZ Reader User’s Manual
6-3
Page 176
Global
Global Total Read Time and Symbol Quality Separator apply to all three Symbol Quality groups: ISO/IEC 15415, Grading, and Inkjet/Direct.
Total Read Time Definition:
The time that transpires between the image capture and the output of the decoded data, including locate time. If enabled, is appended to the symbol.
Serial Cmd:
<K710,[not changed in this context],total read time>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Symbol Quality Separator Definition:
Inserts a separator between each enabled field of the symbol quality output.
Serial Cmd:
<K708,symbol quality separator,output mode>
Default:
<SP> (space character)
Options:
Any ASCII character except a NULL < , or >.
6-4
Quadrus EZ Reader User’s Manual
Page 177
Symbol Quality
Data Matrix Output Mode Note: Output Mode applies to both ISO/IEC 15415 and Inkjet/Direct symbol quality parameters. Definition:
Output Mode specifies how the four output parameters, if enabled, are formatted.
Serial Cmd:
<K708,symbol quality separator,output mode>
Default:
Grade
Options:
0 = Grade
1 = Value
Grade If in Grade mode, a grade (A,B,C,D) specified by the International Symbology Specification, Data Matrix, is appended to the symbol data.
Value If in Value mode, the calculated value for that parameter is appended to the symbol data.
ISO/IEC 15415 Symbol Quality Symbol Quality parameters specified by ISO/IEC 15415.
Symbol Contrast Usage:
Lets the user know if contrast settings are less than acceptable.
Definition:
All the pixels that fall within the area of the test symbol, including its required zone, will be sorted by their reflectance values to select the darkest 10% and the lightest 10% of the pixels. The arithmetic mean of the darkest and the lightest pixels is calculated and the difference of the two means is the Symbol Contrast. (ANSI) Symbol Contrast grade is defined in this way: A (4.0) if SC > 70% B (3.0) if SC > 55% C (2.0) if SC > 40% D (1.0) if SC > 20% F (0.0) if SC < 20% If enabled, the symbol contrast is appended to the symbol data according to the ISO/IEC 15415 Symbol Quality Output Mode setting.
Serial Cmd:
<K709,symbol contrast,print growth,axial non-uniformity,unused ecc>
Default:
Disabled
Options:
0 = Disabled
Quadrus EZ Reader User’s Manual
1 = Enabled
6-5
Page 178
Data Matrix
Print Growth
Definition:
The extent to which dark or light markings appropriately fill or exceed their module boundaries. These values are determined by counting pixels in the clock pattern of the binary digitized image, then comparing it to a nominal value and Min. and Max. values. (ISO/IEC 15415) Print Growth grade is defined in this way: A (4.0) if -.050 < D < 0.50B (3.0) if -.070 < D < 0.70 C (2.0) if -.085 < D < 0.85D (1.0) if -.1.00 < D < 1.00 F (0.0) if D <-1.00 or D >1.00 If enabled, the print growth is appended to the symbol data according to the ISO/IEC 15415 Symbol Quality Output Mode setting.
Serial Cmd:
<K709,symbol contrast,print growth,axial non-uniformity,unused ecc>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Axial Non-Uniformity
Definition:
Axial non-uniformity is a measure of how much the sampling point spacing differs from one axis to another, namely AN = abs (XAVG - YAVG) /((XAVG +YAVG)/2) where abs () yields the absolute value. If a symbology has more than two major axes, then AN is computed for those two average spacings which differ the most. (ANSI) Axial non-uniformity grade is defined in this way: A (4.0) if AN < .06 B (3.0) if AN < .08 C (2.0) if AN < .10 D (1.0) if AN < .12 F (0.0) if AN > .12 If enabled, the axial non-uniformity is appended to the symbol data according to the ISO/IEC 15415 Symbol Quality Output Mode setting.
Serial Cmd:
<K709,symbol contrast,print growth,axial non-uniformity,unused ecc>
Default:
Disabled
Options:
0 = Disabled
6-6
1 = Enabled
Quadrus EZ Reader User’s Manual
Page 179
Symbol Quality
Unused Error Correction
Definition:
The correction capacity of Reed-Solomon decoding is expressed in the equation, e + 2d < d - p, where e is the number of erasures, t is the number of errors, d is the number of error correction code words, and p is the number of code words reserved for error detection. The Unused ECC (Error Correction Code) parameter tests the extent to which regional or spot damage in the symbol has eroded the reading safety margin that error correction provides. (ISO/IEC 15415) Unused ECC grade is defined in this way: A (4.0) if UEC > .62 B (3.0) if UEC > .50 C (2.0) if UEC > .37D (1.0) if UEC > .25 F (0.0) if UEC < .25 If enabled, the unused ECC is appended to the symbol data according to the ISO/IEC 15415 Symbol Quality Output Mode setting.
Serial Cmd:
<K709,symbol contrast,print growth,axial non-uniformity,unused ecc>
Default:
Disabled
Options:
0 = Disabled
Quadrus EZ Reader User’s Manual
1 = Enabled
6-7
Page 180
Data Matrix
Grading Symbol Quality Percent Cell Damage Definition:
Number of cells (also called elements) damaged per total number of cells x 100. The ideal reading is 0 (zero). If enabled, is appended to the symbol.
Serial Cmd:
<K710,percent cell damage,total read time,capture time,locate time,decode time,pixels per element,ecc level,matrix size,quiet zone>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Capture Time Definition:
Capture time (in milliseconds) is a fixed “overhead” that includes the time of capture and transfer of the image. If enabled, is appended to the symbol.
Serial Cmd:
<K710,percent cell damage,total read time,capture time,locate time,decode time,pixels per element,ecc level,matrix size,quiet zone>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Locate Time Definition:
The time in milliseconds from the start of image processing until the symbol has been located and is ready to be decoded. If enabled, is appended to the symbol.
Serial Cmd:
<K710,percent cell damage,total read time,capture time,locate time,decode time,pixels per element,ecc level,matrix size,quiet zone>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Decode Time Definition:
The time in milliseconds required to decode a symbol. If enabled, is appended to the symbol.
Serial Cmd:
<K710,percent cell damage,total read time,capture time,locate time,decode time,pixels per element,ecc level,matrix size,quiet zone>
Default:
Disabled
Options:
0 = Disabled
6-8
1 = Enabled
Quadrus EZ Reader User’s Manual