Page 121

I/O Parameters

Good Read Usage:

Good Read is used when an application requires all symbol data to be transmitted. It’s typically used in tracking applications in which each object is uniquely identified.

Definition:

With Good Read enabled, the reader transmits symbol data on any good read regardless of Matchcode Type setting. Note: A noread can still be transmitted if enabled.

Quadrus EZ Reader User’s Manual

5-5

Page 122

When to Output Symbol Data

When to Output Symbol Data Definition:

This command allows the user to choose when symbol data can be sent to the host.

Serial Cmd:

<K705,symbol data output status,when to output>

Default:

As Soon As Possible

Options:

0 = As Soon As Possible

1 = End of Read Cycle

As Soon As Possible Usage:

Definition:

As Soon As Possible is useful in applications in which symbol data needs to be moved quickly to the host, typically when the host is making decisions based on symbol data. Enabling As Soon As Possible causes symbol data to be sent to the host immediately after a symbol has been successfully decoded. Note: More than one decode might in fact be required to qualify as a good read, depending on how Decodes Before Output is set.

End of Read Cycle Usage:

End of Read Cycle is useful in timing-based systems in which the host is not ready to accept data at the time it is decoded. Enabling End of Read Cycle means that symbol data does not get sent to the host until the read cycle ends with a timeout or new trigger.

End of read cycle

Start of read cycle Definition: Read cycle duration Host activates trigger

This is when host expects output

Read Cycle

5-6

Quadrus EZ Reader User’s Manual

Page 123

I/O Parameters

Noread Message Usage:

Used in applications where the host needs serial verification that a symbol has not been read and especially useful in new print verification.

Definition:

When enabled, and if no symbol has been decoded before timeout or the end of the read cycle, the noread message will be transmitted to the host.

Noread Message Mode Serial Cmd:

<K714,noread message status,noread message>

Default:

Enabled

Options:

0 = Disabled

1 = Enabled

2 = Detailed Noread Message

Disabled No message is output when a noread condition occurs.

Enabled The user-defined noread message is output whenever a noread condition occurs.

Detailed Noread Message Important: In the case where the conditions set in Bad/No Symbol Qualification are met, then the Bad Symbol or No Symbol message output will override the Noread Message or the Detailed Noread Message, if either is enabled. Usage:

Use this option to cover more detailed reasons for decode failures.

Definition:

Outputs a Noread message followed by an additional message (an Image Processing Results Code) indicating the reason a symbol failed to decode.

For example, in the following output: “NOREAD d_1, E_2” d and E are symbology ids for Datamatrix and UPC respectively. The message means that Datamatrix and UPC are enabled (and other symbologies are not), and that both failed to decode. The reason for the failing Datamatrix is 1 and the reason for the failing UPC is 2. The first part of these numbers (preceding the dot) is the relevant number and interpreted here:

2D Symbologies: 1. Failed to locate symbol (no finder pattern). 2. Failed to locate four corners or failed to qualify user-defined dimension (in pixels). 3. Failed to locate clocks or failed to qualify user-defined orientation (0-359 degree). 4. Failed to validate clocks or failed to qualify user-defined symbol size (clock element count). 5. Failed to decode symbol.

Quadrus EZ Reader User’s Manual

5-7

Page 124

Noread Message

Linear Symbologies: 1. Failed user-defined minimum number of bars. 2. Failed to decode start/stop character (doesn’t apply to UPC, RSS, MicropPDF417 and Pharmacode). 3. Failed user-defined minimum number of scan lines that qualify for the minimum number of bars. 4. Failed to decode. 5. Failed to decode UPC supplemental.

5-8

Quadrus EZ Reader User’s Manual

Page 125

I/O Parameters

Noread Message Definition:

Any combination of ASCII characters can be defined as the noread message.

Serial Cmd:

<K714,noread message status,noread message>

Default:

NOREAD

Options: 0 to 128 ASCII characters. Note: Noread Message will only be transmitted if Symbol Data Output is set to Match, Mismatch or Good Read. Noread Message can be set to any ASCII characters except NULL < , or >.

Quadrus EZ Reader User’s Manual

5-9

Page 126

Bad/No Symbol Qualification

Bad/No Symbol Qualification Usage:

Useful in determining if a symbol is present and if user-defined requirements for that symbol are met.

Definition:

Sets the requirements that will qualify an object or a symbol before outputting a decode or message.

Bad Symbol Message Usage:

Can tell the user if a qualified symbol is present but not decodable.

Definition:

When enabled, sends a message to the host whenever an object meets specified qualifications for “bad symbol” status.

Serial Cmd:

<K715,[unused],message>

Default:

BAD_SYMBOL

Options:

Up to 128 ASCII characters (except NULL)

No Symbol Message Usage:

Can tell the user if a object does not qualify as a symbol.

Definition:

When enabled, send a message to the host whenever an object meets specified qualifications for “no symbol” status but is not decoded.

Serial Cmd:

<K716,[unused],message>

Default:

NO_SYMBOL

Options:

Up to 128 ASCII characters (except NULL)

1D/Stacked Symbology Qualification Minimum Number of Bars Definition:

Sets the minimum number of bars to qualify linear symbols.

Serial Cmd:

<K717,minimum number of bars,minimum number of qualified scans,start/stop status>

Default:

0

Options:

0 to 255 (0 is disabled)

5-10

Quadrus EZ Reader User’s Manual

Page 127

I/O Parameters

Minimum Number of Qualified Scan Lines Definition:

Sets the minimum number of scans that have the required number of bars set in Minimum Number of Bars.

Serial Cmd:

<K717,minimum number of bars,minimum number of qualified scans,start and stop status>

Default:

0

Options:

0 to 11 (0 is disabled)

Start/Stop Status

Definition:

When enabled, both Start and Stop characters need to be present to qualify as a decodable symbol. In the case of PDF417, only a Stop or Stop needs to be present. Note: This parameter does not apply to UPC, Pharmacode, RSS and Micro PDF417.

Serial Cmd:

<K717,minimum number of bars,minimum number of qualified scans,start and stop status>

Default:

Disabled

Options:

0 = Disabled

Quadrus EZ Reader User’s Manual

1 = Enabled

5-11

Page 128

Bad/No Symbol Qualification

2D Symbology Qualification Note: in the cases where Symbol Size Status, Dimension Status, or Orientation Status is enabled, the reader will always check the finder pattern regardless of Finder Pattern Status setting.

Finder Pattern Status Definition:

Checks for the presence of finder pattern.

Serial Cmd:

<K718,finder pattern status,symbol size mode,symbol size 1,symbol size 2,symbol size tolerance,dimension mode,dimension 1,dimension 2,dimension tolerance,orientation mode,orientation value>

Default:

Disabled

Options:

0 = Disabled

1 = Enabled

Symbol Size Mode (2D Symbology Qualification) Note: if Symbol Size 1 is larger than Symbol Size 2, it will be automatically reversed in the algorithm. Definition:

Specifies the outputs resulting from the results of searches for Symbol Size 1 and Symbol Size 2.

Serial Cmd:

<K718,finder pattern status,symbol size mode,symbol size 1,symbol size 2,symbol size tolerance,dimension mode,dimension 1,dimension 2,dimension tolerance,orientation mode,orientation value>

Default:

Disabled

Options:

0 = Disabled 1 = Bad/No Symbol Output 2 = Object Qualification 3 = Enable Both

Disabled Decoded messages are output, but no attempt to qualify symbols or output Bad or No Symbol messages is undertaken.

Bad/No Symbol Output Checks first for decodes. If no symbol is decoded, checks for symbol size. If both Symbol Size 1 and Symbol Size 2 requirement are met, a Bad Symbol message is output. If both are not met, outputs a No Symbol message.

Object Qualification Checks first for matches to symbol size. If qualified, attempts to decode. If no decodes are found within the specified read cycle parameters, outputs a Noread message.

Enable Both Same as Object Qualification, except that if no objects qualify, then a No Symbol message is output; if at least one object qualifies, then a Bad Symbol message is output. 5-12

Quadrus EZ Reader User’s Manual

Page 129

I/O Parameters

Symbol Size 1 (2D Symbology Qualification) Definition:

Checks for symbol sizes for a specified number of elements. In the case of rectangular symbols, checks the longer side.

Serial Cmd:

<K718,finder pattern status,symbol size status,symbol size 1,symbol size 2,symbol size tolerance,dimension mode,dimension 1,dimension 2,dimension tolerance,orientation mode,orientation value>

Default:

10

Options:

8 to 88 elements

Symbol Size 2 (2D Symbology Qualification) Definition:

Checks for symbol sizes for a specified number of elements. In the case of rectangular symbols, checks the shorter side.

Serial Cmd:

<K718,finder pattern status,symbol size status,symbol size 1,symbol size 2,symbol size tolerance,dimension mode,dimension 1,dimension 2,dimension tolerance,orientation mode,orientation value>

Default:

10

Options:

8 to 88 elements

Symbol Size Tolerance (2D Symbology Qualification) Definition:

Sets the allowable deviation, up or down, for symbol sizes specified in Symbol Size 1 and Symbol Size 2.

Serial Cmd:

<K718,finder pattern status,symbol size status,symbol size 1,symbol size 2,symbol size tolerance,dimension mode,dimension 1,dimension 2,dimension tolerance,orientation mode,orientation value>

Default:

2

Options:

0 to 10

Quadrus EZ Reader User’s Manual

5-13

Page 130

Bad/No Symbol Qualification

Dimension Mode (2D Symbology Qualification) Definition:

Enables the searches for symbol Dimension 1 and Dimension 2.

Serial Cmd:

<K718,finder pattern status,symbol size status,symbol size 1,symbol size 2,symbol size tolerance,dimension mode,dimension 1,dimension 2,dimension tolerance,orientation mode,orientation value>

Default:

Disabled

Options:

0 = Disabled 1 = Bad/no symbol output 2 = Object qualification 3 = Enable both

Disabled Decoded messages are output, but no attempt to qualify symbols or output Bad or No Symbol messages is undertaken.

Bad/No Symbol Output Checks first for decodes. If no symbol is decoded, checks for symbol dimension. If both Dimension 1 and Dimension 2 requirements are met, a Bad Symbol message is output. If both are not met, outputs a No Symbol message.

Object Qualification Checks first for matches to symbol dimension. If qualified, attempts to decode. If no decodes are found within the specified read cycle parameters, outputs a Noread message.

Enable Both Same as Object Qualification, except that if neither Dimension 1 nor Dimension 2 qualifies, then a No Symbol message is output; if either Dimension 1 or Dimension 2 qualifies, then a Bad Symbol message is output.

Dimension 1 (2D Symbology Qualification) Definition:

Checks symbol dimension for a specified number of pixels. In the case of rectangular symbols, checks the longer side.

Serial Cmd:

<K718,finder pattern status,symbol size status,symbol size 1,symbol size 2,symbol size tolerance,dimension mode,dimension 1,dimension 2,dimension tolerance,orientation mode,orientation value>

Default:

0

Options:

0 to 656 pixels

5-14