Page 111
Symbologies
MicroPDF417 Usage:
Used for labeling small items that need large capacity.
Definition:
A variant of PDF417, a very efficient and compact stacked symbology that can encode up to 250 alphanumeric characters or 366 numeric characters per symbol.
Serial Cmd:
<K485,status,[usused],fixed symbol length status,fixed symbol length>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Fixed Symbol Length Status (MicroPDF417) Serial Cmd:
<K485,status,[unused],fixed symbol length status,fixed symbol length>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Fixed Symbol Length (MicroPDF417) Usage:
Used to increase data integrity by ensuring that only one symbol length will be accepted.
Definition:
When enabled, the Micro PDF symbol must contain the same number of characters as the symbol length setting before it can be considered a good read. The reader will ignore any symbol not having the specified length.
Serial Cmd:
<K485,status,[unused],fixed symbol length status,fixed symbol length>
Default:
10
Options: 1 to 2710 Note: Fixed Symbol Length Status must be enabled for Fixed Symbol Length to take effect.
Quadrus EZ Reader User’s Manual
4-27
Page 112
Composite
Composite When set to Enabled or Required, will attempt to decode the composite component of a linear symbol. The linear symbol can be RSS14, RSS Expanded, RSS Limited, UCC/EAN128, UPC-A, EAN-13, EAN-8, and UPC-E. Usage:
Allows reading by both linear and 2D readers.
Definition:
Combines 2D and linear width modulated symbology on the same symbol where different messages can be read by each reader type.
Serial Cmd:
<K453,mode,separator status,separator>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Required
Enabled If set to Enabled it only decodes the linear component, it will output only the linear component.
Required If set to Required, it must decode both the linear and the composite components; otherwise it outputs a noread.
Separator Status (Composite) Usage: Definition: Serial Cmd: Default: Options:
Allows user to distinguish between the main and Supplemental symbols. This separator separates the linear symbol and the composite component. <K453,mode,separator status,separator> Disabled 0 = Disabled 1 = Enabled
Separator Character (Composite) Note: If Separator Character has been changed to any other character and you wish to re-define the separator as a comma, you will need to use ESP or the embedded menu. Usage: Definition: Serial Cmd: Default: Options:
4-28
As required by the application. Allows the user to change the separator character from a comma to a new character. <K453,mode,separator status,separator> , (comma) Any ASCII character
Quadrus EZ Reader User’s Manual
Page 113
Symbologies
Narrow Margins Note: Narrow Margins is only used for linear symbology types. Do not use with PDF. Usage:
Used when the leading and trailing edges of the symbols are smaller than the standard margin or other objects encroach into the margins.
Definition:
Allows the reader to read symbols with quiet zones less than 8 times the width of the narrow bar element. “Quiet zone” is the space at the leading and trailing ends of a symbol. Each quiet zone can be as narrow as only five times the width of the narrow bar element when Narrow Margins is enabled.
Serial Cmd:
<K450,narrow margins,symbology identifier status>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Note: Do not use Narrow Margins with Large Intercharacter Gap enabled in Code 39.
Quadrus EZ Reader User’s Manual
4-29
Page 114
Symbology ID
Symbology ID Usage:
Used when the symbology type and how it’s decoded needs to be known.
Definition:
Symbology ID is an ISO/IEC 16022 standard prefix set of characters that identifies the symbol type. When enabled, the reader analyzes and identifies the symbology and adds a three character identifying prefix to the data: 1. ] (close bracket character) indicating the presence of a symbology ID 2. A, C, E, I, L, Q, b, d, p A = Code 39; C = Code 128; E = UPC/EAN; I = I–2/5; L = PDF417; Q = QR Code; b = BC412; d = Data Matrix; p = Pharmacode 3. Modifier
Serial Cmd:
<K450, narrow margins,symbology identifier status>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Explanation of Modifiers for Code 39, Codabar, and I–2/5 • For Code 39, Codabar and I 2/5, the modifier indicates Check Digit and Check Digit Output status. • For Code 39 only, Full ASCII needs to be enabled to see modifiers 4, 5, and 7. Modifier
Check Digit
0 1 3 4 5 7
Disabled Enabled Enabled Disabled Enabled Enabled
Check Digit Output N/A Enabled Disabled N/A Enabled Disabled
Full ASCII conversion performed (Code 39 only) No No No Yes Yes Yes
Example:]A5 indicates a Code 39 symbol with Check Digit and Check Digit Output enabled and Full ASCII conversion performed.
Explanation of Modifiers for Other Symbologies • For Code 128, a 1 indicates ECC/EAN-128; otherwise the modifier is a 0. • For QR Code, a 0 indicates Model 1; a 1 indicates Model 2. • For all other codes, the modifier is 0.
4-30
Quadrus EZ Reader User’s Manual
Page 115
Symbologies
Background Color Usage:
If the background is darker than the symbol, then enable black background. Typically the background is white; but on PCBs for example, they can be black.
Definition:
Allows the user to choose which symbol background (white or black) the reader can read.
Serial Cmd:
<K451, background color>
Default:
White
Options:
0 = White
Quadrus EZ Reader User’s Manual
1 = Black
4-31
Page 116
Background Color
4-32
Quadrus EZ Reader User’s Manual
Page 117
5 I/0 Parameters Contents I/O Parameters by ESP.................................................................................................................5-2 I/O Parameters Serial Commands ................................................................................................5-3 Symbol Data Output......................................................................................................................5-4 When to Output Symbol Data .......................................................................................................5-6 Noread Message...........................................................................................................................5-7 Bad/No Symbol Qualification ......................................................................................................5-10 Read Duration Output .................................................................................................................5-18 Output Indicators.........................................................................................................................5-19 Serial Verification ........................................................................................................................5-23 Video Output ...............................................................................................................................5-25 Image Output ..............................................................................................................................5-28 Image Captioning ........................................................................................................................5-30 Synchronous Trigger...................................................................................................................5-32 EZ Button ....................................................................................................................................5-34 Input 1 .........................................................................................................................................5-38 Output 1 Parameters...................................................................................................................5-39 Output 2 Parameters...................................................................................................................5-52 Output 3 Parameters...................................................................................................................5-54
This section includes instructions on setting up conditions for changing input/output electrical transitions for control of internal and external devices. A discrete I/O (in/out) signal is an electrical transition from one voltage level to another so that digital switching can occur. Note: The characters NULL <> and , can only be entered through embedded menus, not through ESP or serial commands.
Quadrus EZ Reader User’s Manual
5-1
Page 118
I/O Parameters by ESP
I/O Parameters by ESP
Click this button to bring up the I/O menu.
To open nested options, singleclick the +.
To change a setting, double-click the setting and use your cursor to scroll through the options.
5-2
Quadrus EZ Reader User’s Manual
Page 119
I/O Parameters
I/O Parameters Serial Commands Symbol Data Output <K705,symbol data output status,when to output> Noread Message <K714,noread message status,noread message> Bad Symbol Message <K715,[unused],message> No Symbol Message <K716,[unused],message> 1D/Stacked Symbology Qualifi<K717,minimum number of bars,minimum number of qualified scans,start/stop status> cation <K718,finder pattern status,symbol size mode,symbol size 1,symbol size 2,symbol size 2D Symbology tolerance,dimension mode,dimension 1,dimension 2,dimension tolerance,orientation Qualification mode,orientation value> Read Duration Output <K706,status,separator> LED Indicators <K750,green flash mode,x-pattern status,green flash duration> Beeper <K702,beeper status> LED Configuration <K737,LED mode,ISO/IEC 15415 grade,DPM grade> Serial Verification <K701,serial command echo status,serial command beep status,control/hex output> Video Output <K760,video output mode,trigger image mode,image frame> Image Output <K739,image output mode,comm port,file format,JPEQ quality> Image Captioning <K762,mode> Synchronous Trigger <K761,synchronous trigger mode> EZ Button <K770,global status,default on power-on,load IP database,save for power-on> EZ Button Modes <K771,position 1 mode,position 2 mode,position 3 mode,position 4 mode> Input 1 <K730,input mode,active state> Output 1 Parameters <K810,output on,active state,pulse width,output mode> Trend Analysis Output 1 <K780,trend analysis mode,number of triggers,number to output on> <K800,output on symbol contrast,symbol contrast threshold,output on print growth,print Symbol Quality (ISO/IEC growth threshold,output on axial non-uniformity,axial non-uniformity threshold,output on 15415) to Output 1 unused ecc,unused ecc threshold> Symbol Quality (Inkjet/Direct) <K820,output on dot center offset,dot center offset,output on cell fill,cell fill,output on dot to Output 1 ovality,dot ovality threshold,output on angle of distortion,angle of distortion threshold> Diagnostic Warnings <K790,over temp,service unit,external camera disconnect> to Output 1 Output 2 <K811,output on,active state,pulse width,output mode> Trend Analysis Output 2 <K781,trend analysis mode,trigger evaluation period,number to output on> <K801,output on symbol contrast,symbol contrast threshold,output on print growth,print Symbol Quality (ISO/IEC growth threshold,output on axial non-uniformity,axial non-uniformity threshold,output on 15415) to Output 2 unused ecc,unused ecc threshold> Symbol Quality (Inkjet/Direct) <K821,output on dot center offset,dot center offset,output on cell fill,cell fill,output on dot to Output 2 ovality,dot ovality threshold,output on angle of distortion,angle of distortion threshold> Diagnostic Warnings <K791,over temp,service unit,external camera disconnect> to Output 2 Output 3 <K812,output on,active state,pulse width,output mode> Trend Analysis Output 3 <K782,trend analysis mode,trigger evaluation period,number to output on> Symbol Quality (ISO/IEC <K802,output on symbol contrast,symbol contrast threshold,output on print growth,print 15415) growth threshold,output on axial non-uniformity,axial non-uniformity threshold,output on to Output 3 unused ecc,unused ecc threshold> Symbol Quality (Inkjet/Direct) <K822,output on dot center offset,dot center offset,output on cell fill,cell fill,output on dot to Output 3 ovality,dot ovality threshold,output on angle of distortion,angle of distortion threshold> Diagnostic Warnings <K792,over temp,service unit,external camera disconnect> to Output 3
Quadrus EZ Reader User’s Manual
5-3
Page 120
Symbol Data Output
Symbol Data Output Note: Symbol Data Output relates to data and should not to be confused with Outputs 1, 2, and 3 listed in the Outputs Parameters which describe output states and functions. Usage:
Useful when the host needs symbol data only under certain conditions.
Definition:
Defines the conditions under which decoded symbol data is transmitted to the host.
Serial Cmd:
<K705,symbol data output status,when to output>
Default:
Good Read
Options:
0 = Disabled 2 = Mismatch
1 = Match 3 = Good Read
Note: Symbol Data Output Status if set to Match or Mismatch will not take effect unless Matchcode Type is enabled and a master symbol is loaded into memory.
Disabled Usage:
It is useful when an application only needs to use the discrete outputs and can allow the reader to do the decision-making. When Disabled, the host does not need the symbol data and the communication lines are used only for setup and status checks.
Definition:
When set to Disabled, the reader will not transmit any data that is generated during a read cycle (symbols, noreads, etc.).
Match Usage:
Match is used in an application that requires specific symbol information and needs to sort, route or verify based on matching the specific symbol data.
Definition:
When set to Match, the reader transmits symbol data whenever a symbol matches a master symbol. However, if Matchcode Type is Disabled, it transmits on any good read. Note: A noread can still be transmitted if Enabled.
Mismatch Usage:
Mismatch is typically used as a flag within the host system to prevent an item from being routed in the wrong container.
Definition:
With Mismatch enabled, the reader transmits symbol data whenever the symbol data information does NOT match the master symbol. Note: A noread can still be transmitted if enabled.
5-4
Quadrus EZ Reader User’s Manual