Page 101
Symbologies
UPC/EAN Usage:
Definition:
Serial Cmd: Default: Options:
Used primarily in POS application in the retail industry. It is commonly used with Microscan readers in applications in combination with Matchcode when there is a need to verify that the right product is being placed in the right packaging. UPC (Universal Product Code) is a fixed length numeric, continuous symbology. UPC can have two- or five-digit supplemental bar code data following the normal code. The U.P.C., Version A (U.P.C., A) symbol is used to encode a 12 digit number. The first digit is the number system character, the next five are the manufacturer number, the next five are the product number, and the last digit is the checksum character. When enabled, the scanner will read UPC version A and UPC version E only. <K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type> Disabled 0 = Disabled 1 = Enabled
EAN Status Usage:
Definition:
Serial Cmd: Default: Options:
EAN is the European version of the UPC symbology and is used in European market applications. Note: UPC must be enabled for EAN to take effect. EAN is a subset of UPC. When enabled, the scanner will read UPC version A, UPC version E, EAN 13, and EAN 8. It also appends a leading zero to UPC version A symbol information and transmits 13 digits. If transmitting 13 digits when reading UPC version A symbols is not desired, disable EAN. Note: The extra character identifies the country of origin. <K473,UPC status,EAN status,supplementals status, separator status, separator character,supplemental type> Disabled 0 = Disabled 1 = Enabled
Quadrus EZ Reader User’s Manual
4-17
Page 102
UPC/EAN
Supplementals Status (UPC/EAN) Usage: Definition: Serial Cmd: Default: Options:
Reads Supplementals typically used in publications and documentation. A supplemental is a 2 or 5 digit symbol appended to the main symbol. When set to Enabled or Required, the scanner reads supplemental bar code data that has been appended to the standard UPC or EAN codes. <K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type> Disabled 0 = Disabled 1 = Enabled 2 = Required
Disabled UPC Supplementals will not be decoded.
Enabled When enabled, the scanner will try to decode a main and a supplemental. However, if a supplemental is not decoded, at the end of the read cycle, the main will be sent by itself.
Required When set to Required, both the main and the supplemental symbols must be read or a single noread condition results. For example, if Supplementals is set to Required, Separator is enabled, and an asterisk is defined as the UPC separator character, then the data will be displayed as: MAIN * SUPPLEMENTAL. Note: Under no circumstances will the supplemental symbol data be sent without a main symbol. Note: If additional symbols - other than the main or supplemental - will be read in the same read cycle, Number of Symbols should be set accordingly.
Separator Status (UPC/EAN) Usage: Definition: Serial Cmd: Default: Options:
4-18
Allows user to distinguish between the main and Supplemental symbols. Allows the user to insert a character between the standard UPC or EAN symbology and the supplemental symbology when Supplementals is set to Enabled or Required. <K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type> Disabled 0 = Disabled 1 = Enabled
Quadrus EZ Reader User’s Manual
Page 103
Symbologies
Separator Character (UPC/EAN) Note: If Separator Character has been changed to any other character and you wish to re-define the separator as a comma, you will need to use ESP or the embedded menu. Usage:
As required by the application. Allows the user to change the separator character from a comma to a new Definition: character. <K473,UPC status,EAN status,supplementals status,separator status, Serial Cmd: separator character,supplemental type> Default: , (comma) Options: Any ASCII character Note: Whenever Separator Character is defined as a comma (,) sending a <K473,s?> command will return the current settings including the separator character comma which appears after the separator status comma.
Supplementals Type (UPC/EAN) Usage: Definition: Serial Cmd: Default: Options:
As required by symbology used in application. Allows the user to select 2 character or 5 character supplements, or both. <K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type> Both 0 = Both 1 = 2 char only 2 = 5 char only
Both Either 2 character or 5 character supplementals will be considered valid.
2 Characters Only Only two character supplementals will be considered valid.
5 Characters Only Only five character supplementals will be considered valid.
Quadrus EZ Reader User’s Manual
4-19
Page 104
Pharmacode
Pharmacode Usage:
Definition:
Serial Cmd: Default: Options:
Used mostly with packaging for the pharmaceuticals industry. Encodes up to five different numbers, each with its own color which may be entered in decimal or “binary” format with a 1 represented by a thick bar and a 0 represented by a thin bar. Bar width is independent of height. In decimal format, each part can be up to 999999. In binary format, each input have up to 19 ones and zeros. <K477,status,fixed symbol length status,fixed symbol length,min. no. of bars,bar width status,direction,fixed threshold value> Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length Status (Pharmacode) Definition: Serial Cmd: Default: Options:
When enabled, the reader will check the symbol length against the symbol length field. If disabled, any length would be considered a valid symbol. <K477,status,fixed symbol length status,fixed symbol length,min. no. of bars,bar width status,direction,fixed threshold value> Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length (Pharmacode) Definition: Serial Cmd: Default: Options:
This specifies the exact number of characters that the reader will recognize (this does not include start and stop and check digit characters). The reader ignores any symbology not having the specified length. <K477,status,fixed symbol length status,fixed symbol length,min. no. of bars,bar width status,direction,fixed threshold value> 10 4 to 16
Minimum Number of Bars (Pharmacode) Definition: Serial Cmd: Default: Options:
4-20
Sets the minimum number of bars that a pharmacode symbol must have to be considered as a valid symbol. <K477,status,fixed symbol length status,fixed symbol length,min. no. of bars,bar width status,direction,fixed threshold value> 4 4 to 16
Quadrus EZ Reader User’s Manual
Page 105
Symbologies
Bar Width Status (Pharmacode) Definition:
Serial Cmd: Default: Options:
If set to Mixed, it will autodiscriminate between narrow bars and wide bars. If set to All Narrow, all bars will be considered as narrow bars. If set to All Wide, all bars will be considered as wide bars. If set to Fixed Threshold, it will use the Fixed Threshold value to determine whether the bars are narrow or wide. The Bar Width Status setting will be ignored when the reader is able to tell the difference between the narrow and the wide bars. <K477,status,fixed symbol length status,fixed symbol length,min. no. of bars, bar width status,direction,fixed threshold value> Mixed 0 = Mixed 1 = All Narrow 2 = All Wide 3 = Fixed Threshold
Direction (Pharmacode) Definition: Serial Cmd: Default: Options:
Specifies the direction that a symbol can be read. <K477,status,fixed symbol length status,fixed symbol length,min. no. of bars, bar width status,direction,fixed threshold value> Forward 0 = Forward 1 = Reverse
Fixed Threshold Value (Pharmacode) Definition: Serial Cmd: Default: Options:
Used when Bar Width Status is set to Fixed Threshold. Defines the minimum difference in pixels that will distinguish a narrow bar from a wide bar. <K477,status,fixed symbol length status,fixed symbol length,min. no. of bars,bar width status,direction,fixed threshold value> 10 1 to 65535
Quadrus EZ Reader User’s Manual
4-21
Page 106
RSS Expanded
RSS Expanded Usage:
Used to encode primary and supplementary data in retail point-of-sale and other applications.
Definition:
RSS Expanded is a variable length symbology that can encode supplementary information in addition to the 14-digit EAN.UCC item identification number and is capable of encoding up to 74 numeric or 41 alphabetic characters.
Serial Cmd:
<K484,status,fixed symbol length status,fixed symbol length>
Default:
Disabled
Options:
0 = Disabled 1 = Enabled (non-stacked) 2 = Enabled (stacked and non-stacked)
Where appropriate, use 1 (non-stacked) for better performance over 2 (stacked and nonstacked).
Fixed Symbol Length Status (RSS Expanded) Definition:
When enabled, the reader will check the symbol length against the symbol length field, minus the embedded check digit. If disabled, any length would be considered a valid symbol.
Serial Cmd:
<K484,status,fixed symbol length status,fixed symbol length>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Fixed Symbol Length (RSS Expanded) Usage:
Fixed Symbol Length helps prevent truncations and increases data integrity by ensuring that only one symbol length will be accepted.
Definition:
Specifies the exact number of characters that the reader will recognize (this does not include start and stop and check digit characters). The reader ignores any symbol not having the specified length.
Serial Cmd:
<K484,status,fixed symbol length status,fixed symbol length>
Default:
10
Options:
1 to 74
4-22
Quadrus EZ Reader User’s Manual
Page 107
Symbologies
RSS Limited Usage:
RSS Limited is designed to be read by laser and CCD readers. It is not recommended for omnidirectional slot scanners.
Definition:
Encodes a smaller 14-digit symbol (74 modules wide) that is not omnidirectional.
Serial Cmd:
<K483,status>
Default:
Disabled
Options:
0 = Disabled 1 = Enabled
Quadrus EZ Reader User’s Manual
4-23
Page 108
RSS-14
RSS-14 Usage:
Used in the grocery retail and prescription drug industries where full 14-digit EAN.UCC item identification may be needed.
Definition:
RSS-14 (Reduced Space Symbology) is a fixed length symbology that encodes 14-digits, including a 1 digit indicator digit and is 96 modules wide. It can be stacked into two rows, read omnidirectional if printed in full height, or not if height-truncated for small marking.
Serial Cmd:
<K482,status>
Default:
Disabled
Options:
0 = Disabled 1 = Enabled (non-stacked) 2 = Enabled (stacked and non-stacked)
Where appropriate, use 1 (non-stacked) for better performance over 2 (stacked and nonstacked).
4-24
Quadrus EZ Reader User’s Manual
Page 109
Symbologies
PDF417 Usage:
Used in applications where a large amount of information (over 32 characters) needs to be encoded within a symbol, typically where the symbol is transported from one facility to another. For example, an automobile assembly line might use a single symbol with multiple fields of information that will be read at several stations along the way, without reference to a database.
Definition:
A two-dimensional, multi-row (3 to 90), continuous, variable length symbology that has high data capacity for storing up to 2700 numeric characters, 1800 printable ASCII characters, or 1100 binary character per symbol. Each symbol character consists of 4 bars and 4 spaces in a 17-module structure.
Serial Cmd:
<K476,status,[unused],fixed symbol length status,fixed symbol length,[unused],codeword collection>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Note: Sending <a1> will cause PDF417 data to be prefaced with information consisting of error correction level (ECC Level n), number of rows (n Rows), number of columns (n Columns), number of informative code words (n Info Code Words) and the number of data characters (n Data Bytes). This feature can be disabled by re-sending <a1>.
Fixed Symbol Length Status (PDF417) Serial Cmd:
<K476,status,[unused],fixed symbol length status,fixed symbol length,[unused],codeword collection>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Fixed Symbol Length (PDF417) Usage:
Used to increase data integrity by ensuring that only one symbol length will be accepted.
Definition:
When enabled, the PDF symbol must contain the same number of characters as the symbol length setting before it can be considered a good read. The reader will ignore any symbol not having the specified length.
Serial Cmd:
<K476,status,[unused],fixed symbol length status,fixed symbol length,[unused],codeword collection>
Default:
10
Options: 1 to 2710 Note: Fixed Symbol Length Status must be enabled for Fixed Symbol Length to take effect.
Quadrus EZ Reader User’s Manual
4-25
Page 110
PDF417
Codeword Collection (PDF417) Usage:
Multiple Codeword Collection is useful in applications where portions of subsequent images can be read and pieced together so that no opportunity or time is lost to assemble codewords for decoding.
Definition:
When set to Multiple, PDF codewords is collected from multiple images and assembled throughout the read cycle until the read cycle ends or the symbol is fully decoded. It is important to note that when this feature is enabled, only one PDF symbol should be presented to the reader per read cycle.
Serial Cmd:
<K476,status,[unused],fixed symbol length status,fixed symbol length,[unused],codeword collection>
Default:
Single Image
Options: 0 = Single Image 1 = Multiple Image Note: Fixed Symbol Length Status must be enabled for Fixed Symbol Length to take effect.
4-26
Quadrus EZ Reader User’s Manual